INDUSTRIAL POWER SUPPLIES ATCPWR Series OVERVIEW ATCPWR Industrial 24 VDC DIN Rail-Mount Power Supply series comes complete with built-in active power factor cor- rection. Compact space-saving design models ranging from 60 watts to 480 watts and available with AC universal supply voltage (90-264 VAC) are cULus listed / UL 508 approved. All models offer built-in protection against short-circuit, overload, overvoltage, and over-temperature conditions, with efficiencies ranging from 87% to 93.5% @ 230 VAC. 24V Industrial Power Supplies
FEATURES
- Supports 90-264 VAC / 127-370 VDC
- Built-In Power Factor Correction
- Protection Against Short Circuit, Overload, Overvoltage, and Over Temperature
- Cooling By Free Air Convection
- Robust Input/Output Terminal Connections
- UL-508 Approved (E206430)
- RoHS, CE, and REACH Compliant
ORDERING INFORMATION
60 W, 24 V / 2.5 A DIN rail mounted Power Supply in Plastic HousingATC60W24V
120 W, 24 V / 5 A DIN rail mounted
Power Supply in Plastic HousingATC120W24V
240 W, 24 V / 10 A DIN rail mounted
Power Supply in Plastic HousingATC240W24V
480 W, 24 V / 20 A DIN rail mounted
Power Supply in Plastic HousingATC480W24V SPECIFICATIONS ATC60W24V ATC120W24V ATC240W24V ATC480W24V OUTPUT
24 VNominal DC Voltage
20 A10 A5 A2.5 ARated Current 0 - 20 A0 - 10 A0 - 5 A0 - 2.5 ACurrent Range
480 W240 W120 W60 WRated Power
< 1% of VoutRipple & Noise (max) 24 to 28 VVoltage Adj. Range ± 1%Voltage Tolerance ± 1%± 0.5%Line Regulation ± 1%Load Regulation < 2 sec; at Full load< 1 sec at 230 VAC & < 3 sec at 115 VAC, Full loadTurn On Time > 20 mS at 24 V & > 12 mS at 28 V at 115 /
230 VAC, Full load
25 mS at 24 V & > 16 mS at 28 V at 115 / 230 VAC, Full load ≥ 60 ms at 230 VAC & ≥ 15 ms at 115 VAC, Full loadHold Up Time < 100 msRise Time INPUT 90 - 264 VAC / 127 - 370VDC De-rate output power linearly below 100 VAC from 100% at 100 VAC to 90% at 90 VAC 90 - 264 VAC / 127 - 370 VDCVoltage Range* 50 / 60 HzFrequency Range > 0.95 at Full load over entire input rangePower Factor > 93.5%> 93%Up to 89%Up to 87%Efficiency @ 230V AC
4.8 A at 115 VAC;
2.4 A at 230 VAC
2.4 A at 115 VAC;
1.2 A at 230 VAC
2.2 A at 115 VAC;
1.5 A at 230 VAC
1.2 A at 115 VAC;
0.8 A at 230 VACAC Current
- Although power supply will work for the specified DC input voltage range, UL approval is only for the specified AC input voltage range. Diversified Electronics 800.727.5646 atcdiversified.com
ATCPWR SeriesINDUSTRIAL POWER SUPPLIES SPECIFICATIONS (CONT .) ATC480W24VATC240W24VATC120W24VATC60W24V INPUT (CONT.) < 60 Amps; Measured at 264 VAC, 25°C Ambient, Cold start < 48 Amps; Measured at 264 VAC, 25°C Ambient, Cold startInrush Current < 1 mA; 264 VAC inputLeakage Current PROTECTION 110% to 140% of rated output current; Hiccup type; Autorecovery > 110% of rated output current; Hiccup type, AutorecoveryOverload 31 VDC ± 0.5 VDC31.5 VDC ± 1 VDCOvervoltage Latched type; Input AC power to be recycled to recover the power supply Hiccup mode when output is shorted; Autorecovery typeOutput Short Circuit Power supply shuts down when the temper- ature of PCB below main transformer reaches typically 120°C; Turns on only after the temperature falls below 90°C typically and AC power is recycled thereafter. The power supply shuts down when the tempera- ture of PCB below PFC choke reaches typically 120°C. It recovers auto- matically when tempera- ture falls to typically 90°C Power supply shuts down when the temperature of PCB below main transformer reaches typically 120°C; Turns on only after the temperature falls below 90°C typically and AC power is recycled thereafter. Over Temperature FUNCTION Contact closes at 23.0V (typ.) Contact opens at 22.5V (typ.) DC OK Signal Contact Rating: 30 VDC 1 A; 60 VDC 0.5 A; 125 VAC 0.5 A; resistive load, min. current 1mA ENVIRONMENT - 25°C to + 70°C; De-rate linearly above 50°C from 100% load at 50°C to 50% load at 70°C, - 25°C to 0°C startup is guaranteed with specification deviation (Output ripple can be more than 10% of the output voltage.) Operating Temperature - 40°C to + 85°CStorage Temperature Natural convection cooledCooling 5 to 95% RH, Non condensingHumidity 2000 mAltitude Component: 10 ~ 500 Hz, 2 G 10 min. / 1 cycle, period for 60 min. each along X, Y,Z axesVibration SAFETY & EMC I/P to Earth: 2500 VAC O/P to Earth: 1500 VAC I/P to O/P: 4000 VAC O/P to DC-OK: 500 VAC I/P to Earth: 2500 VAC I/P to O/P: 4000 VAC O/P to Earth: 1500 VAC OTHERS 60 x 154 x 158.55 mm (W x H x D) 50 x 136 x 135 mm (W x H x D) 43 x 109.8 x 102.7mm (W x H x D) 43 x 109.8 x 102.7 mm (W x H x D)Dimension 1050 gms645 gms350 gms285 gmsWeight 35 mm DIN railMounting Diversified Electronics 800.727.5646 atcdiversified.com
INDUSTRIAL POWER SUPPLIES ATCPWR Series COMPLIANCE APPLICABLE EMI / EMC STANDARDS Conducted Emission Reference Standards: CISPR11 Testing Level: ATC60W24V/ATC120W24V:CLASS A ATC240W24V/ATC480W24V:CLASS B Radiated Emission Reference Standards: CISPR22 Testing Level: CLASS A Electrostatic Discharge Reference Standards: IEC 61000-4-2 Testing Level: Level 4, Criteria A; Level 3, Criteria A Radiated Susceptibility Reference Standards: IEC 61000-4-3 Testing Level: Level 3, Criteria B Electrical Fast Transient / Burst Reference Standards: IEC 61000-4-4 Testing Level: Level 3, Criteria A Surge Reference Standards: IEC 61000-4-5 Testing Level: Level 3, Criteria A Conducted Susceptibility Reference Standards: IEC 61000-4-6 Testing Level: Level 3, Criteria B Power Frequency Magnetic Field Reference Standards: IEC 61000-4-8 Testing Level: Level 4, Criteria A Voltage Dips & Interruption Reference Standards: IEC 61000-4-11 Testing Level: Criteria A & B Safety UL 508 approved (E206430); Designed to meet IEC 62368-1 TERMINAL CONNECTIONS DIMENSIONS (MILLIMETERS) DERATING CURVEDERATING CURVE POWER DERATING W. R. T. AMBIENT TEMPERATURE (ALL MODELS) POWER DERATING W. R. T. INPUT VOLTAGE (ATC240W24V / ATC480W24V) Diversified Electronics 800.727.5646 atcdiversified.com