Technical content
Diversified Electronics 800.727.5646 atcdiversified.com PHASE VOLTAGE MONITORS SLJ Series INCLUDES A DELAY-ON-MAKE TIMER Phase & Under Voltage Monitor DIMENSIONS (INCHES) WIRING MODEL OPERATING DROP-OUT PICK-UP DELAY-ON OUTPUT RATING NUMBER VOLTAGE 1 Ø LOW 3 Ø LOW RELEASE SLJ-120-ALE 95-130 V . Adj. 79-108 V 85-117 V 1 Volt Above 0.5 Sec DPDT, 345 VA Inductive; SLJ-230-ALE 190-270 V . Adj. 158-224 V 171-243 V Drop-out 10 Amps Resistive @ 240 VAC SLJ-380-ALE 350-440 V . Adj. 290-365 V 315-396 V 2.0 Sec DPDT, 360 VA Inductive; SLJ-440-ALE 430-480 V . Adj. 357-398 V 387-432 V 3 Amps Resistive @ 600 VAC All voltage referenced are phase-to-phase. The SLJ Series has a built-in Delay-on-Make Time Delay. The SLJ con- tinuously monitors the three phase lines for adverse conditions such as PHASE LOSS (single phasing), UNDER VOLTAGE (brown outs), and PHASE REVERSAL (improper sequence). When any of these conditions occur, the internal relay will de-energize (DROP-OUT). When the fault is corrected, the field adjustable Delay-on Make delay begins. Upon completion of the time delay, the internal relay will energize (PICK-UP). Any subsequent interruptions will reset the delay period. The SLJ’s phase monitor operates the same as the SLA Series. It will drop-out for a phase loss if any phase drops below 83% of its nominal setting and it will also drop-out for under voltage if all three phases drop below 90% of its nominal setting. It is phase sequence sensitive and will not allow start-up if the three phases are reversed. The SLJ is available in the same standard operating voltage ranges as our other Phase Monitors (see table below). The Delay-on-Make Timer is field adjustable from 0.2 to 8.0 minutes. There are two LED indicators. The green indicator glows when all condi - tions are normal, and the red indicator glows when the internal relay is energized. The SLJ is ideally suited for multiple equipment installations to stagger start equipment after a fault condition. SPECIFICATIONS OPERATING See Table Below VOLTAGE OUTPUT RATING See Table Below INDICATORS LED Green LED Glows When All Conditions Are Normal Red LED Glows When Relay is Energized RESPONSE TIMES Operate 0.2 to 8.0 Minutes, Adjustable Release See Table Below TEMPERATURE Operate 32° to +131°F (0° to +55°C) RATING Storage -49° to 185°F (-45° to +85°C) ENCLOSURE Style “E” Lexan, Surface Mounted TERMINATIONS (12) #8-32 Screw Terminals WEIGHT 14 oz.