EDS2011-002 EUROPA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

This document must be retained for future reference. It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should also be inspected periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS2011-002 Page 1 of 5 Features & Benefits

  • Clearly labelled earth and neutral bars positioned at the top of the enclosure
  • Din rail position allows a generous wiring space
  • T op, bottom and side knockouts for cable entries- multiple entries for consumer unit tails on all sides
  • Retain-screws for lid included, prevent screws from being lost during installation
  • Busbar with cover and fingertip protection provided
  • Type 2 SPD included
  • Multiple configurations from main-switched boards to SPD-protected fully loaded circuits available to suit a wide range of applications Part Number Description SLCU6M-SPD 6 Module | 2 usable ways SLCU8M-SPD 8 Module | 4 usable ways SLCU10M-SPD 10 Module | 6 usable ways SLCU12M-SPD 12 Module | 8 usable ways SLCU14M-SPD 14 Module | 10 usable ways SLCU16M-SPD 16 Module | 14 usable ways SLCU18M-SPD 18 Module | 12 usable ways SLCU20M-SPD 20 Module | 16 usable ways

Description

The distribution equipment and circuit protection range of metal consumer units by Europa Components are designed to fully comply with the requirements of BS EN 61439-3 and the requirements of the18th Edition of BS 7671 IET Wiring Regulations. With multiple configurations available, the range offers flexible versatile solutions for installations. Sentinel Range Consumer Units Metal-Clad Single-Phase Boards IP20 with Type 2 SPD

Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS2011-002 Page 2 of 5 Unit Dimensions Part Number W W1 H H1 SLCU6M-SPD 161 111 235 165 SLCU8M-SPD 197 132 SLCU10M-SPD 233 168 SLCU12M-SPD 279 203 SLCU14M-SPD 305 240 SLCU16M-SPD 341 276 SLCU18M-SPD 377 312 SLCU20M-SPD 431 366 Part Number Breakdown Number of modules: 6, 8, 10, 12, 14, 16, 18, 20 Sentinel Range of Metal Consumer Units Configuration (1): M - Main Switch Configuration (2): SPD - SPD (Type 2) + MCB Included Notes This unit must be installed by a skilled or instructed person in accordance with the current BS 7671 IET Wiring Regulations The product must be tested by skilled persons competent for verification after installation and before being put to service Please ensure these instructions are available to the end user for future reference T otal load not to exceed the rating of the incoming main switch or RCCB The total sum of the individual MCB ratings may exceed this value where there is an appropriate diversity factor on the installation (see diversity factor table below) It is important to ensure that all connections, including factory-made, must be checked for the correct installation and tightness, prior to the commissioning of the electrical installation This product is only suitable for indoor installation Sentinel Range Consumer Units Metal-Clad Single-Phase Boards IP20 with Type 2 SPD

Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS2011-002 Page 3 of 5 Notes: Knockout placements are symmetrical between top and bottom / left and right sides. Sentinel Range Consumer Units Metal-Clad Single-Phase Boards IP20 with Type 2 SPD

Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS2011-002 Page 4 of 5 Rated and operational voltage (Un / Ue) 230V AC at 50Hz Rated impulse withstand voltage (Uimp) 4kV Rated current of Assembly (InA) 100A Rated frequency (fn) 50Hz Degree of Protection IP20 Mechanical Impact Protection IK05 Note: Rated diversity factor (RDF) only applies to continuously and simultaneously loaded circuits. Type A Distribution Board for use by ordinary persons. SPD Specification BS / EN Standard BS EN 61643-11 Type Type 2 Earthing System TT/TN System Voltage 230V Max. Continuous Operation AC Voltage 275V (L-N) | 255V (N-PE) Nominal Discharge Current In 20kA Maximum Discharge Current Imax 40kA Voltage Protection Level Up 1.5kV (L-N) | 1.2kV Status Indicator Green (Normal State) | Red (Failure State) Mounting 35mm DIN Rail Terminal Capacity 2.5mm² (L/N) | 4mm² (PE) Operating Temperature ~40 to ~80 °C Degree of Protection IP20 Unit Characteristics Sentinel Range Consumer Units Metal-Clad Single-Phase Boards IP20 with Type 2 SPD

Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS2011-002 Page 5 of 5 Number of Outgoing Ways Assumed loading factor 2 & 3 0.8 4 & 5 0.7 6 to 9 0.6 10+ 0.5 Diversity Factors as per BS EN 61439-3 Device Max Cable Capacity (mm2) Recommended Tightening Torque (Nm) Main Switch / RCCBs 35 2.5 MCBs 16 2.0 1 Pole RCBO 16 In 2.0 | Out 1.2 Earth and Neutral Terminals 25 2.0 Cable and Torque Settings Device Standard Consumer Unit BS EN 61439-3 Main Switch BS EN 60947-3 RCCB BS EN 61008-1 MCB BS EN 60898-1 RCBO BS EN 61009-1 Standards Sentinel Range Consumer Units Metal-Clad Single-Phase Boards IP20 with Type 2 SPD