This document must be retained for future reference. It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore ‘fit for purpose’. Factors such as correct selection of components, cable sizing, protective devices and Earth bonding are all critical and should be checked prior to full testing and power-up. Any other regulations applicable to the equipment being installed such as the Machinery Directive and current health and safety legislation must also be adhered to. All connections (including factory made) must be checked for the correct tightness prior to commissioning of the electrical installation. All connections should also be inspected periodically to ensure correct tightness. DO NOT USE POWER TOOLS ON THESE PRODUCTS Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS1392-004 Page 1 of 4 EUR PA Sentinel Range Consumer Units Metal-Clad Single-Phase Boards IP20 The distribution equipment and circuit protection range of metal consumer units by Europa Components are designed to fully comply with the requirements of BS EN 61439-3, EN 61439-3 and the requirements of the18th Edition of BS 7671 IET Wiring Regulations. With multiple configurations available, the range offers flexible versatile solutions for installations. Features & Benefits

  • Clearly labelled earth and neutral bars positioned at the top of the enclosure.
  • Din rail position allows a generous wiring space.
  • Top, bottom and side knockouts for cable entries- multiple entries for consumer unit tails on all sides.
  • Retain-screws for lid included, prevent screws from being lost during installation. Part Number Breakdown Part Number Description SLCU6 6 Module Empty CU Enclosure SLCU8 8 Module Empty CU Enclosure SLCU10 10 Module Empty CU Enclosure SLCU12 12 Module Empty CU Enclosure SLCU14 14 Module Empty CU Enclosure SLCU20 20 Module Empty CU Enclosure SLCU6R 6 Module 80A 2-Pole Type A RCD 4 Free Ways SLCU8R 8 Module 80A 2-Pole Type A RCD 6 Free Ways SLCU10R 10 Way + 80A 2-Pole Type A RCD 8 Free ways SLCU12R 12 Way + 80A 2-Pole Type A RCD 10 Free ways SLCU14R 14 Way + 80A 2-Pole Type A RCD 12 free ways SLCU20R 20 Way + 80A 2-Pole Type A RCD 18 free ways SLCU24-DT 24 (2 X 12) Module Empty CU Enclosure SLCU36-DT 36 (2 X 18) Module Empty CU Enclosure Sentinel Range of Metal Consumer Units Configuration: R - RCCB Board Leave blank for empty boards Number of modules: 6, 8, 10, 12, 14, 20, 24, 36 S UCL DT- Double Tier

Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS1392-004 Page 2 of 4 EUR PA Part Number W W1 H H1 SLCU6 | SLCU6R 161 111 235 165 SLCU8 | SLCU8R 197 132 SLCU10 | SLCU10R 233 168 SLCU12 | SLCU12R 279 203 SLCU14 | SLCU14R 305 240 SLCU20 | SLCU20R 431 366 SLCU24-DT 279 203 465 395 SLCU36-DT 377 312 Unit Dimensions Notes: Knockout placements are symmetrical between top and bottom / left and right sides. Double-tier board has double the number of side knockouts.

Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS1392-004 Page 3 of 4 EUR PA Unit Characteristics Rated and operational voltage (Un / Ue) 230V AC at 50Hz Rated impulse withstand voltage (Uimp) 4kV Rated current of Assembly (lnA) 100A, 63A, 40A Rated frequency (fn) 50Hz Degree of Protection IP20 Mechanical Impact Protection IK05 Note: Rated diversity factor (RDF) only applies to continuously and simultaneously loaded circuits. Type A Distribution Board for use by ordinary persons. Device Standard Consumer Unit BS EN 61439-3 / EN 61439-3 Main Switch BS EN 60947-3 / EN 60947-3 RCCB BS EN 61008-1 / EN 61008-1 MCB BS EN 60898-1 / EN 60898-1 RCBO BS EN 61009-1 / EN 61009-1 Number of Outgoing Ways Assumed loading factor 2 & 3 0.8 4 & 5 0.7 6 to 9 0.6 10+ 0.5 Device Max Cable Capacity (mm2) Recommended Tightening Torque (Nm) Main Switch / RCCBs 35 2.5 MCBs 16 2.0 1 Pole RCBO 16 In 2.0 | Out 1.2 Earth and Neutral Terminals 25 2.0 Cable and Torque Settings Diversity Factors as per BS EN 61439-3 Standards ENSURE THAT THESE INSTRUCTIONS ARE MADE AVAILABLE TO THE END USER FOR FUTURE REFERENCE WARNING! ALL CONNECTIONS, INCLUDING FACTORY- MADE, MUST BE CHECKED FOR THE CORRECT INSTALLATION AND TIGHTNESS, PRIOR TO THE COMMISSIONING OF THE ELECTRICAL INSTALLATION. Widest pin to be installed in the main switch or an RCCB feeding MCBs End cap Raised lip for finger protection Fitting the Busbar Fully open the terminals and insert the busbar within the clamp correctly. Ensure that the widest pin is inserted to the main switch or the RCCB which is feeding the downstream MCBs. The busbar cover provided has a raised lip on one side which provides finger protection when the busbar is installed. Ensure that this lip is facing up when installing the busbar. Ensure the end caps provided are used to fully cover the busbar when installed.

Europa House, Airport Way, Luton, Bedfordshire, LU2 9NH Technical: 01582 692 444 technical@europa-plc.com www.europa-plc.com Data Sheet EDS1392-004 Page 4 of 4 EUR PA Recommended Accessories for the Range Part Number Description SLCUACC01KIT Accessory Kit Sticker and Way Labels, Pin Covers, Grommet Strip SLCUNC16280 Flexible Neutral Cable (Blue) 16mm2 280mm long SLCUBB-10 10-Way Flexible Busbar with Cover SLCUBB-14 14-Way Flexible Busbar with Cover SLCUBB-18 18-Way Flexible Busbar with Cover SLCUMMB Metal Blank Module Covers SLCUSPD2KIT Type 2 SPD Kit (inc. Type 2 SPD, 32A MCB + Wiring) AUSP-40J/1+1 Type 2 SPD Single Module Wide SLCU6LL Lockable Lid for 6-Way Boards SLCU8LL Lockable Lid for 8-Way Boards SLCU10LL Lockable Lid for 10-Way Boards SLCU12LL Lockable Lid for 12-Way Boards SLCU14LL Lockable Lid for 14-Way Boards SLCU16LL Lockable Lid for 16-Way Boards SLCU18LL Lockable Lid for 18-Way Boards SLCU20LL Lockable Lid for 20-Way Boards Notes This unit must be installed by a skilled or instructed person in accordance with the current BS 7671 IET Wiring Regulations The product must be tested by skilled persons competent for verification after installation and before being put to service Please ensure these instructions are available to the end user for future reference Total load not to exceed the rating of the incoming main switch or RCCB The total sum of the individual MCB ratings may exceed this value where there is an appropriate diversity factor on the installation (see diversity factor table above) It is important to ensure that all connections, including factory-made, must be checked for the correct installation and tightness, prior to the commissioning of the electrical installation This product is only suitable for indoor installation