Features

 Two Linear Optocouplers in compact 16 SOIC package  High servo linearity (K3) across temperature  Low input power consumption  High Isolation Voltage (1500V RMS)  Long Life / High stability / High Reliability  RoHS / Pb-Free / REACH Compliant NOTE: Suffixes listed above are not included in marking on device for part number identification 3 14 16(-) Input (+) Input PD1 Cathode PD 2 Cathode Do Not Use Do Not Use SLC1600 5 12 13PD1 Anode Do Not Use (-) Input 8 9 11Do Not Use PD2 Anode PD 1 Anode 7 10PD2 Cathode PD 1 Cathode PD2 Anode (+) Input K2K1 IF I1 I2 IF I1I2

© 2012 Solid State Optronics • San José, CA Page 2 of 8 SLC1600/TR Rev 2.01 (09/17/2012) 001528 SLC1600 Dual Channel Linear Optocoupler Parameter Symbol Min. Typ. Max. Units Test Conditions Input Specifications LED Forward Voltage V F - 1.2 1.5 V I F = 10mA LED Reverse Voltage BV R 6 - - V I R = 10μA Terminal Capacitance C t - 30 250 pF V=0, f=1KHz Reverse Current I R - - 10 A VR=6V Coupled Specifications K1 Servo Gain (I1/IF) K1 0.002 0.004 0.01 n/a I F=1-10mA K2 Forward Gain (I2/IF) K2 0.002 0.004 0.01 n/a I F=1-10mA K3 Transfer Gain (K2/K1) K3 0.98 1.00 1.02 n/a I F=0.3-10mA Transfer Gain Linearity ∆K3 - 0.07 0.1 % I F=0.3-10mA Photo-Conductive Operation Frequency Response (-3dB) - - 140 - kHz  IF=10mA, ∆V=2V Phase Response - - -45 - DEG  f=140kHz Isolation Specifications Isolation Voltage V ISO 1500 - - V RMS RH ≤ 50%, t=1min Input-Output Resistance R I-O - 10 -  VI-O = 500VDC Electrical Characteristics, TA = 25°C (unless otherwise specified)

© 2012 Solid State Optronics • San José, CA Page 3 of 8 SLC1600/TR Rev 2.01 (09/17/2012) 001528 SLC1600 Dual Channel Linear Optocoupler SLC1600 Performance & Characteristics Plots, TA = 25°C (unless otherwise specified)

© 2012 Solid State Optronics • San José, CA Page 4 of 8 SLC1600/TR Rev 2.01 (09/17/2012) 001528 SLC1600 Dual Channel Linear Optocoupler Process Step Description Parameter A Preheat Start Temperature (ºC) 150ºC B Preheat Finish Temperature (ºC) 180ºC C Preheat Time (s) 90 - 120s D Melting Temperature (ºC) 230ºC E Time above Melting Temperature (s) 30s F Peak Temperature, at Terminal (ºC) 260ºC G Dwell Time at Peak Temperature (s) 10s H Cool-down (ºC/s) <6ºC/s SLC1600 Solder Reflow Temperature Profile Recommendations (1) Infrared Reflow: Refer to the following figure as an example of an optimal temperature profile for single occurrence infrared reflow. Soldering process should not exceed temperature or time limits expressed herein. Su rface temperature of device package should not exceed 250ºC: A B C D F E G H (2) Wave Solder: (3) Hand Solder: Maximum Temperature: 260ºC (at terminal) Maximum Time: 10s Pre-heating: 100 - 150ºC (30 - 90s) Single Occurrence Maximum Temperature: 350ºC (at tip of soldering iron) Maximum Time: 3s Single Occurrence

© 2012 Solid State Optronics • San José, CA Page 5 of 8 SLC1600/TR Rev 2.01 (09/17/2012) 001528 SLC1600 Dual Channel Linear Optocoupler All dimensions in inches [“] with millimeters in parenthesis (mm)

© 2012 Solid State Optronics • San José, CA Page 6 of 8 SLC1600/TR Rev 2.01 (09/17/2012) 001528 SLC1600 Dual Channel Linear Optocoupler

16 PIN SOIC Footprint Note:

All dimensions in inches [“] with millimeters in parenthesis (mm)

© 2012 Solid State Optronics • San José, CA Page 7 of 8 SLC1600/TR Rev 2.01 (09/17/2012) 001528 SLC1600 Dual Channel Linear Optocoupler

© 2012 Solid State Optronics • San José, CA Page 8 of 8 SLC1600/TR Rev 2.01 (09/17/2012) 001528 SLC1600 Dual Channel Linear Optocoupler Solid State Optronics (SSO) makes no warranties or representations with regards to the completeness and accuracy of this document. SSO reserves the right to make changes to product description, specifications at any time without further notices. SSO shall not assume any liability arising out of the application or use of any product or circuit described herein. Neither circuit patent licenses nor indemnity are expressed or implied. Except as specified in SSO’s Standard Terms & Conditions, SSO disclaims liability for consequential or other damage, and we make no other warranty, expressed or implied, including merchantability and fitness for particular use. DISCLAIMER SSO does not authorize use of its devices in life support applications wherein failure or malfunction of a device may lead to personal injury or death. Users of SSO devices in life support applications assume all risks of such use and agree to indemnify SSO against any and all damages resulting from such use. Life support devices are defined as devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when used properly in accordance with instructions for use can be reasonably expected to result in significant injury to the user, or (d) a critical component of a life support device or system whose failure can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness. LIFE SUPPORT POLICY