SCA3060-D01 VTI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Features

3,0 V – 3.6 V supply voltage 2 g measurement range 16 bit SPI digital interface Selectable frequency response Very low current consumption (3.3 V, 150 A typ) 64 samples/axis buffer memory for output acceleration data and advanced features enable significant power and resource savings at system level Interrupt signal triggered by motion Size 7.6 x 3.3 x 8.6 mm (w x h x l) Proven capacitive 3D-MEMS technology High shock durability RoHS compliant / lead free soldering AEC Q-100 qualified

Applications

SCA3060-D01 is targeted to automotive applications such as Inertial navigation Vehicle alarms Inclination sensing Motion activation Black box systems Figure 1 SCA3060-D01 Block Diagram Data Sheet INT C/V An a log calibrat i on & ADC D E- MUX 1:3 Low - pass Filter Low - pass Filter Low - pass Filter Decimation Decimation Dec i mation Coordinate Mapping and Calibrat i on Oscill a tor & clock Motion detector Non - Vola tile Memory Reference SPI i/f Control & INT SCK M I SO MOSI CSB Ring Buffer Temperat u re se n sor

VTI Technologies Oy 2/3 2/4 www.vti.fi Doc. Nr. 82 1040 00 D RevD Performance Characteristics 1) Parameter Condition Units Min Typ 1) Max Analog and digital Vdd 3.0 3.3 3.6 V Operating temperature ** -40 - 105 °C Current consumption * Reset 2) - <9 - A Measurement / MD mode - 150 - A Acceleration range * 3) Nominal - ± 2 - g Total offset error 4) -40 ... +105 °C -200 ±200 +200 mg Sensitivity * 6) - 1000 - Count/g Total Sensitivity error * - ±2% ±4% % Non-Linearity 7) - ±1 ±3% % FS Cross-Axis sensitivity 8) - ±3 - % Bandwidth 9) Measurement mode 9 Hz Wide band mode 35 Hz Noise 10) Measurement mode 9 mg RMS Wide band mode - 16 - mg RMS Output data rate Measurement mode 50 Hz Wide band mode 100 Hz Start up time 11) - 200 - ms Output load - - 35 pF SPI clock rate - - 325 kHz * 100% tested in production ** Qualified during product validation 1) Typical values are not guaranteed. 2) Includes the current through the internal 400 k pull-up resistor connected to digital I/O Vdd. 3) Range defined as gzyx 2222 . The measuring range is tested on sensing element level. FS = 2g. 4) Includes effects over supply voltage, temperature and life time 6) Sensitivity = {Count(+1g) - Count(-1g)}/2 [Count/g]. 7) From straight line through sensitivity calibration (+1g, -1g) points. 8) The cross-axis sensitivity determines how much acceleration, perpendicular to the measuring axis, couples to the output. The total cross-axis sensitivity is the geometric sum of the sensitivities of the two axes which are perpendicular to the measuring axis. The angular alignment error between X, Y and Z axis is included into the cross axis sensitivity. 9) Frequency responses according to Figure 4. 10) Average noise/axis over the measurement bandwidth defined as )222(3 znynxn , where nx, ny and nz are the measured signal's standard deviation due to noise in x, y and z directions. 11) Settling error less than 1% of FS.

VTI Technologies Oy 4/3 4/4 www.vti.fi Doc. Nr. 82 1040 00 D RevD Document Change Control Author Approved by Tommi Vilenius Department/Role Product Manager Rev. Date Change Description Author Reviewed by ECN 0 5.12.2008 Preliminary release A1 23.1.2009 Initial release TVi VNu, TOS B1 4.3.2009 Changes to low power component C 21.9.2009 Performance values updated, pin naming updated. Tvi TOS, JL D 21.11.2011 Product description modified TVi JUP