DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 10
Technical content
Data Sheet of SAW Components Note : Murata SAW Component is applicable for Cellular /Cordless phone (Terminal) relevant market only. Please also read caution at the end of this document.
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 Package Dimensions Specification (fc=1900MHz) (1) (8)(9) (6)(7) Others Unit : Unbalance Port (1900/2017.5MHz) : Balance Port (1900MHz) : Balance Port (2017.5MHz) : Ground : mm 1.50±0.05 1.10±0.05 Dot Marking( 0.3) (0.15) 0.5max. (C0.15) 6-0.21±0.03 (6) (7) (8) (9) (5) (10) (4) (3) (2) (1) (0.07) 8-0.18±0.03 0.39±0.030.49±0.03 2-0.18±0.03 5-0.21±0.03 (0.075) 8-0.18±0.03 (4)(3)(2)(1) (6)(7)(8)(9) (10) (5) E F Marking: Laser Printing *: EIAJ Code (Refer to the table 1) $ : Date Code (Refer to the table 2) Nominal Center Frequency(fc) 1) 0.1 to 1000 MHz 45 dB min. 45 dB min. 60 dB 2) 1000 to 1500 MHz 29 dB min. 29 dB min. 45 dB 3) 1500 to 1795 MHz 29 dB min. 29 dB min. 34 dB 4) 1795 to 1820 MHz 15 dB min. 15 dB min. 35 dB 5) 1820 to 1840 MHz 10 dB min. 10 dB min. 26 dB 6) 1980 to 2005 MHz 15 dB min. 15 dB min. 28 dB 7) 2005 to 2110 MHz 25 dB min. 25 dB min. 28 dB 8) 2110 to 2500 MHz 29 dB min. 29 dB min. 40 dB 9) 2500 to 3000 MHz 32 dB min. 32 dB min. 40 dB 10) 3000 to 4500 MHz 35 dB min. 35 dB min. 46 dB 11) 4500 to 6000 MHz 30 dB min. 30 dB min. 44 dB Phase Balance (1880 to 1920MHz) 180.0+5.8deg.180±12deg. max. 180±12deg. max. 50Ω//6.2nH 0.8 dB max. 1.3 (1880 to 1920MHz) 0.3 dB 2.0 max. Amplitude Balance (1880 to 1920MHz) Input Signal Level 20mW (+13dBm), 2000 hours (1880 to 1920MHz) 1.0 dB max. VSWR Balance Port Matching Impedance (nominal) 200Ω//30nH 2.0 max. Unbalance Port Matching Impedance (nominal) Absolute Attenuation Ripple Deviation Insertion Loss Item (1880 to 1920MHz) 1900MHz Specification -30 to 85°C 1.7 25±2°C typ. dB2.3 dB max. 2.0 dB max. Top View Bottom View
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 Frequency Performance Amplitude balance Phase balance (fc=1900MHz)
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 Package Dimensions (fc=2017.5MHz) Specification 1.50±0.05 1.10±0.05 Dot Marking( 0.3) (0.15) 0.5max. (C0.15) 6-0.21±0.03 (6) (7) (8) (9) (5) (10) (4) (3) (2) (1) (0.07) 8-0.18±0.03 0.39±0.030.49±0.03 2-0.18±0.03 5-0.21±0.03 (0.075) 8-0.18±0.03 (4)(3)(2)(1) (6)(7)(8)(9) (10) (5) E F (1) (8)(9) (6)(7) Others Unit : Unbalance Port (1900/2017.5MHz) : Balance Port (1900MHz) : Balance Port (2017.5MHz) : Ground : mm Nominal Center Frequency(fc) 1) 0.1 to 1013 MHz 45 dB min. 45 dB min. 63 dB 2) 1013 to 1925 MHz 29 dB min. 29 dB min. 31 dB 3) 1925 to 1950 MHz 14 dB min. 14 dB min. 36 dB 4) 1950 to 1990 MHz 4 dB min. 6 dB min. 10 dB 5) 2045 to 2075 MHz 2 dB min. 2 dB min. 5 dB 6) 2075 to 2110 MHz 20 dB min. 20 dB min. 27 dB 7) 2110 to 2170 MHz 32 dB min. 32 dB min. 36 dB 8) 2170 to 2500 MHz 32 dB min. 32 dB min. 44 dB 9) 2500 to 4000 MHz 43 dB min. 43 dB min. 48 dB 10) 4000 to 6000 MHz 35 dB min. 35 dB min. 41 dB Unbalance Port Matching Impedance (nominal) 50Ω//6.2nH Input Signal Level 20mW (+13dBm), 2000 hours (2010 to 2025MHz) 1.3 Balance Port Matching Impedance (nominal) 200Ω Amplitude Balance (2010 to 2025MHz) Ripple Deviation (2010 to 2025MHz) 1.0 dB max. 2.0 max.2.0 max.VSWR 2017.5MHz Specification -30 to 85°C 25±2°C typ. Absolute Attenuation Insertion Loss Item (2010 to 2025MHz) 0.8 dB max. 0.3 dB Phase Balance (2010 to 2025MHz) 180±10deg. max. 180±10deg. max. 180.0+1.3deg. Marking: Laser Printing *: EIAJ Code (Refer to the table 1) $ : Date Code (Refer to the table 2) Top View Bottom View
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 Frequency Performance Amplitude balance Phase balance (fc=2017.5MHz)
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 5/9 Dimensions of Carrier Tape Dimensions of Reel Dimensions of Tape 160...190 80...120 400...560 Trailer tape Components Leader Cavity Unit: mm Unit: mm Unit: mm SAWFD1G90CA0F0AR00 … 10000pcs/reel SAWFD1G90CA0F0AR1S… sample Order (φ178/330) 9.5±1.0 15.5max. (100) 330) 2.0±0.5 13.0±0.5 2.0±0.5 9.0±0.5 13.5max. (60) 178) 13.0±0.5 A: 8.0 B: 1.75 C: 3.50 D: 4.0 E: 2.00 F: 4.0 G: φ1.5 H: 0.90 J: 1.3 K: 1.7 L: 0.60
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 Recommended Land Pattern Test Circuit 1900MHz 2017.5MHz 4-0.255 6-0.21 4-0.18 0.565 0.465 2-0.18 4-0.21 8-0.25 1.50 1.10 : Land Pattern Unit : mm 50 W 50 W 200 W
200 W30nH
6.2nH 200 W 6.2nH Top View Bottom View
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 7/9 RoHS Compliance This component is compliant with RoHS directive. This component was always RoHS compliant from the first date of manufacture. This rule of code is applied repeatedly every four year. * : EIAJ Code Table 1 Marking code $: Date Code Table 2 date 1st 2nd 3rd 4th 5th 6th 7th 8th 9th 10th code A B C D E F G H J K date 11th 12th 13th 14th 15th 16th 17th 18th 19th 20th code L M N P Q R S T U V date 21st 22nd 23rd 24th 25th 26th 27th 28th 29th 30th 31st code W X Y Z a b c d e f g ・ Caution - Limitation of Applications This product is intended for the following applications only; however, please do not use this product in these applications where defects might directly cause damage to a third party’s life, body or property. a. Mobile Telephone b. Cordless phone (except for Automotive use) c. PC (Including Notebook PC, Netbook PC, Tablet) d. Game e. Camera (except for Business/security use) f. Set Top Box g. Electronic dictionary h. Digital audio equipment ・This catalog is for reference only and not an official product specification document, therefore, please review and approve our official product specification before ordering this product.
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 Important notice PLEASE READ THIS NOTICE BEFORE USING OUR PRODUCTS. Please make sure that your product has been evaluated and confirmed from the aspect of the fitness for the specifications of our product when our product is mounted to your product. All the items and parameters in this product specification/datasheet/catalog have been prescribed on the premise that our product is used for the purpose, under the condition and in the environment specified in this specification. You are requested not to use our product deviating from the condition and the environment specified in this specification. Please note that the only warranty that we provide regarding the products is its conformance to the specifications provided herein. Accordingly, we shall not be responsible for any defects in products or equipment incorporating such products, which are caused under the conditions other than those specified in this specification. WE HEREBY DISCLAIMS ALL OTHER WARRANTIES REGARDING THE PRODUCTS, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, THAT THEY ARE DEFECT-FREE, OR AGAINST INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS. The product shall not be used in any application listed below which requires especially high reliability for the prevention of such defect as may directly cause damage to the third party's life, body or property. You acknowledge and agree that, if you use our products in such applications, we will not be responsible for any failure to meet such requirements. Furthermore, YOU AGREE TO INDEMNIFY AND DEFEND US AND OUR AFFILIATES AGAINST ALL CLAIMS, DAMAGES, COSTS, AND EXPENSES THAT MAY BE INCURRED, INCLUDING WITHOUT LIMITATION, ATTORNEY FEES AND COSTS, DUE TO THE USE OF OUR PRODUCTS IN SUCH APPLICATIONS. - Aircraft equipment. - Aerospace equipment - Undersea equipment. - Power plant control equipment - Medical equipment. - Transportation equipment (vehicles, trains, ships, elevator, etc.). - Traffic signal equipment. - Disaster prevention / crime prevention equipment. - Burning / explosion control equipment - Application of similar complexity and/ or reliability requirements to the applications listed in the above. We expressly prohibit you from analyzing, breaking, Reverse-Engineering, remodeling altering, and reproducing our product. Our product cannot be used for the product which is prohibited from being manufactured, used, and sold by the regulations and laws in the world. Please do not use the product in molding condition This product is ESD (ElectroStatic Discharge) sensitive device. When you install or measure this, you should be careful not to add antistatic electricity or high voltage. Please be advised that you had better check anti serge voltage. We do not warrant or represent that any license, either express or implied, is granted under any our patent right, copyright, mask work right, or our other intellectual property right relating to any combination, machine, or process in which our products or services are used. Information provided by us regarding third-party products or services does not constitute a license from us to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from us under our patents or other intellectual property. Please do not use our products, our technical information and other data provided by us for the purpose of developing of mass-destruction weapons and the purpose of military use. Moreover, you must comply with "foreign exchange and foreign trade law", the "U.S. export administration regulations", etc. Please note that we may discontinue the manufacture of our products, due to reasons such as end of supply of materials and/or components from our suppliers.
Murata part number :SAWFD1G90CA0F0A Feb. 10, 2020 Customer acknowledges that Murata will, if requested by you, conduct a failure analysis for defect or alleged defect of Products only at the level required for consumer grade Products, and thus such analysis may not always be available or be in accordance with your request (for example, in cases where the defect was caused by components in Products supplied to Murata from a third party). The product shall not be used in any other application/model than that of claimed to Murata. Customer acknowledges that engineering samples may deviate from specifications and may contain defects due to their development status. We reject any liability or product warranty for engineering samples. In particular we disclaim liability for damages caused by ・the use of the engineering sample other than for evaluation purposes, particularly the installation or integration in the product to be sold by you, ・deviation or lapse in function of engineering sample, ・improper use of engineering samples. We disclaims any liability for consequential and incidental damages. If you can’t agree the above contents, you should inquire our sales.