S2S4 SHARP | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 15
Technical content
- Recognized by UL1577 (Double protection isolation), file No. E64380 (as model No. S2S4) 2. Approved by CSA, file No. CA95323 (as model No. S2S4) 3. Optionary available VDE Approved (∗)(DIN EN 60747-5-2), file No. 40009162 (as model No. S2S4) 4. Package resin : UL flammability grade (94V-0) (∗) DIN EN60747-5-2 : successor standard of DIN VDE0884. Up to Date code "RD" (December 2003), approval of DIN VDE0884. From Date code "S1" (January 2004), approval of DIN EN60747-5-2. (∗∗) Reinforced insulation type is also available. (PC3SG21YIZ Series) ■ Features ■ Agency approvals/Compliance 1. Triggering for Triacs used to switch on and off devices which require AC Loads. For example heaters, fans, motors, solenoids, and valves. 2. AC line control in power supply applications. ■ Applications VDRM : 600V, Zero cross type Mini-Flat Package Phototriac Coupler for triggering 1. High repetitive peak off-state voltage (VDRM : 600V) 2. Zero crossing functionality (VOX : MAX. 35V) 3. IFT ranks available (see Model Line-up section in this datasheet) 4. 4 pin Mini-flat package 5. Superior noise immunity (dV/dt : MIN. 100V/µs) 6. Lead-free components are also available (see Model Line-up section in this datasheet) 7. Double transfer mold construction (Ideal for Flow Soldering) 8. High isolation voltage between input and output iso(rms) : 3.75kV) ∗Non-zero cross type is also available. (S2S3 Series) ■ Description S2S4 Series Phototriac Coupler include an infrared emitting diode (IRED) optically coupled to an output Phototriac. These devices feature full wave control and are ideal isolated drivers for medium to high current Triacs. SOP package provides 3.75kV isolation from input to output with superior commutative noise immunity. Notice The content of data sheet is subject to change without prior notice. In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. S2S4 Series Sheet No.: D2-A06601EN Date Mar. 31. 2004 © SHARP Corporation
■ Internal Connection Diagram ■ Outline Dimensions Product mass : approx. 0.09gProduct mass : approx. 0.09g (Unit : mm) VDE option S2S4 Series Sheet No.: D2-A06601EN Anode Cathode Anode/Cathode Cathode/Anode Zero Crossing Circuit 2S4 SHARP mark "S" Date code (2 digit) Model No. Factory identification mark 5.3±0.3 −0.2 7.0+0.2 −0.7 Anode mark Epoxy resin 45˚ 0.2±0.05 1 20.4±0.1 4.4±0.2 4 3 3.6±0.3 2.54±0.25 5.3±0.3 −0.2 7.0+0.2 −0.7 Epoxy resin 45˚ 0.2±0.05 1 2 4.4±0.2 4 3 3.6±0.3 2.54±0.25 2S4 SHARP mark "S" Date code (2 digit) Model No. Anode mark Factory identification mark VDE identification mark0.4±0.1
Date code (2 digit) Rank mark There is no rank mark indicator. A.D. 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 Mark A B C D E F H J K L M N Mark P R S T U V W X A B C Mark O N D Month January February March April May June July August September October November December A.D 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012
- ·· 2nd digit Month of production 1st digit Year of production Factory identification mark Factory identification Mark no mark Country of origin Japan Indonesia Philippines China * This factory marking is for identification purpose only. Please contact the local SHARP sales representative to see the actural status of the production. repeats in a 20 year cycle S2S4 Series Sheet No.: D2-A06601EN
■ Electro-optical Characteristics ■ Absolute Maximum Ratings S2S4 Series Sheet No.: D2-A06601EN 0.2mm or more Soldering area Parameter Symbol Rating Unit Input Output (Ta=25˚C) Forward current Reverse voltage RMS ON-state current Peak one cycle surge current Repetitive peak OFF-state voltage Isolation voltage Operating temperature Storage temperature Soldering temperature IF VR IT(rms) Isurge VDRM Viso(rms) Topr Tstg Tsol mA V A A V kV 0.05 0.6 600 3.75 −30 to +100 −40 to +125 260 *1 40 to 60%RH, AC for 1minute, f=60Hz *2 For 10s *3 f=50Hz sine wave Parameter Symbol Unit Input Output (Ta=25˚C) Forward voltage Reverse current Repentitive peak OFF-state current ON-state voltage Holding current Critical rate of rise of OFF-state voltage Zero-cross voltage Minimum trigger current Isolation resistance Turn-on time V F IR IDRM VT IH dV/dt VOX IFT RISO ton V µA µA V mA V/µs V mA Ω µs IF=20mA VR=3V VD=VDRM IT=0.05A VD=6V VD=1/√−2 ·VDRM IF=15mA, Resistance load VD=6V, RL=100Ω DC500V,40 to 60%RH VD=6V, RL=100Ω, IF=20mA Conditions 0.1 100 5×10 1.2 1 000 1.4 2.5 3.5 MIN. TYP. MAX. Transfer charac- teristics No rank Rank R Rank L
■ Model Line-up (1) (Lead-free components) Please contact a local SHARP sales representative to inquire about production status. S2S4 Series Sheet No.: D2-A06601EN ■ Model Line-up (2) (Lead solder plating components) Sleeve 100pcs/sleeve 3 000pcs/reel Taping S2S4000F S2S4R00F S2S4L00F S2S4Y00F S2S4RY0F S2S4LY0F MAX. 10 MAX. 7 MAX. 5 Approved S2S4A00F S2S4RA0F S2S4LA0F S2S4AY0F S2S4RAYF Approved 750pcs/reel S2S4B00F S2S4RB0F S2S4LB0F S2S4BY0F S2S4RBYF Approved Shipping Package DIN EN60747-5-2 Model No. IFT[mA] (VD=6V, RL=100Ω) No rank Rank R Rank L IFT rank Sleeve 100pcs/sleeve 3 000pcs/reel Taping S2S4 S2S4R S2S4L S2S4Y S2S4RY S2S4LY MAX. 10 MAX. 7 MAX. 5 Approved S2S4A S2S4RA S2S4LA S2S4AY S2S4RAY Approved 750pcs/reel S2S4B S2S4RB S2S4LB S2S4BY S2S4RBY Approved Shipping Package DIN EN60747-5-2 Model No. IFT[mA] (VD=6V, RL=100Ω) No rank Rank R Rank L IFT rank
Fig.4 Minimum Trigger Current vs. Ambient Temperature Fig.5 Relative Repetitive Peak OFF-state Voltage vs. Ambient Temperature Fig.6 ON-state Voltage vs. Ambient Temperature Fig.3 Forward Current vs. Forward Voltage Fig.2 RMS ON-state Current vs. Ambient Temperature Fig.1 Forward Current vs. Ambient Temperature S2S4 Series Sheet No.: D2-A06601EN −30 0 50 100 Forward current IF (mA) Ambient temperature Ta (˚C) 01 0.5 1.5 2 2.5 3 100 Forward current IF (mA) Forward voltage VF (V) Ta=100˚C 25˚C75˚C 50˚C 0˚C −30˚C −30 0 50 100 RMS ON-state current IT (rms) (mA) Ambient temperature Ta (˚C) −40 0 −20 20 40 60 80 100 Minimum trigger current IFT (mA) Ambient temperature Ta (˚C) VD=6V RL=100Ω 0.8 1.2 1.4 1.6 1.8 −40 0 −20 20 40 60 80 100 ON-state voltage VT (V) Ambient temperature Ta (˚C) IT=50mA Relative repetitive peak OFF-state voltage VDRM (Tj=Ta) / VDRM (Tj=25°C) 0.7 1.3 1.2 1.1 0.9 0.8 −40 −20 0 20 40 60 80 100 Ambient temperature T a (°C)
Fig.11 Zero-cross Voltage vs. Ambient Temperature Fig.9 Relative Repetitive Peak OFF-state Current vs. Ambient Temperature Fig.10 Turn-on Time vs. Forward Current Fig.7 Holding Current vs. Ambient Temperature Fig.8 Repetitive Peak OFF-state Current vs. OFF-state Voltage S2S4 Series Sheet No.: D2-A06601EN Remarks : Please be aware that all data in the graph are just for reference. Relative repetitive peak OFF-state current IDRM (Tj=Ta) / IRM (Tj=25°C) 0.1 1 000 100 02 0 4 0 6 08 0 100 Ambient temperature Ta (°C) VD=600V 100 ON-state current IT (mA) ON-state voltage VT (V) IF=20mA Ta=25˚C Fig.12 ON-state Current vs. ON-state Voltage 0.1 −40 0 −20 20 40 60 80 100 Holding current IH (mA) Ambient temperature Ta (˚C) VD=6V 0.01 0.1 100 200 300 400 500 600 Repetitive peak OFF-state current IDRM (nA) OFF-state voltage VD (V) Ta=25˚C −40 −20 100 806040200 Zero-cross voltage VOX (V) Ambient temperature Ta (˚C) Resistance load, IF=15mA 100 1 000 11 0 100 Turn-on time tON (µs) Forward current IF (mA) VD=4V RL=100Ω Ta=25˚C
■ Design Considerations In order for the Phototriac to turn off, the triggering current (IF) must be 0.1mA or less. Please refrain from using these devices in a direct drive configuration. These Phototriac Coupler are intended to be used as triggering device for main Triacs. Please ensure that the output rating of these devices will be sufficient for triggering the main output Triac of your choice. Failure to do may result in malfunctions. For applications with inductive loads such as motors, please use caution in utilizing a zero crossing type Pho- totraiac Coupler as this may cause undesired operations due to the phase difference between voltage and current of load. For designs that will experience excessive noise or sudden changes in load voltage, please include an appropriate snubber circuit as shown in the below circuit. Please keep in mind the Sharp Phototriac Coupler incorporate superrior dV/dt ratings which can eliminate the need for a snubber circuit. For over voltage protection, a Varistor may be used.
- Degradation In general, the emission of the IRED used in Phototriac Couplers will degrade over time. In the case where long term operation and / or constant extreme temperature fluctuations will be applied to the devices, please allow for a worst case scenario of 50% degradation over 5years. Therefore in order to maintain proper operation, a design implementing these Phototriac Couplers should provide at least twice the minimum required triggering current from initial operation.
- Recommended Foot Print (reference) (Unit : mm)
- Design guide S2S4 Series Sheet No.: D2-A06601EN 1.5 2.54 0.8 6.3
Sheet No.: D2-A06601EN ✩ For additional design assistance, please review our corresponding Optoelectronic Application Notes.
- Standard Circuit (Medium/High Power Triac Drive Circuit) Triac Load S2S4 Note) Please add the snubber circuit according to a condition. Any snubber or varistor used for the above mentioned scenarios should be located as close to the main output triac as possible. Zero Crossing Circuit AC Line
■ Manufacturing Guidelines Reflow Soldering: Reflow soldering should follow the temperature profile shown below. Soldering should not exceed the curve of temperature profile and time. Please don't solder more than twice.
- Soldering Method Flow Soldering : Due to SHARP's double transfer mold construction submersion in flow solder bath is allowed under the below listed guidelines. Flow soldering should be completed below 260˚C and within 10s. Preheating is within the bounds of 100 to 150˚C and 30 to 80s. Please don't solder more than twice. Hand soldering Hand soldering should be completed within 3s when the point of solder iron is below 400˚C. Please don't solder more than twice. Other notices Please test the soldering method in actual condition and make sure the soldering works fine, since the impact on the junction between the device and PCB varies depending on the tooling and soldering conditions. 123 4 300 200 100 0 0 (˚C) Terminal : 260˚C peak ( package surface : 250˚C peak) Preheat 150 to 180˚C, 120s or less Reflow 220˚C or more, 60s or less (min) S2S4 Series Sheet No.: D2-A06601EN
Solvent cleaning : Solvent temperature should be 45˚C or below. Immersion time should be 3minutes or less. Ultrasonic cleaning : The impact on the device varies depending on the size of the cleaning bath, ultrasonic output, cleaning time, size of PCB and mounting method of the device. Therefore, please make sure the device withstands the ultrasonic cleaning in actual conditions in advance of mass production. Recommended solvent materials : Ethyl alcohol, Methyl alcohol and Isopropyl alcohol. In case the other type of solvent materials are intended to be used, please make sure they work fine in actual using conditions since some materials may erode the packaging resin.
- Cleaning instructions This product shall not contain the following materials. And they are not used in the production process for this device. Regulation substances : CFCs, Halon, Carbon tetrachloride, 1.1.1-Trichloroethane (Methylchloroform) Specific brominated flame retardants such as the PBBOs and PBBs are not used in this product at all.
- Presence of ODC S2S4 Series Sheet No.: D2-A06601EN
■ Package specification 10.5 4.5 4.6 2.8 6.3 400
- Sleeve package Package materials Sleeve : HIPS (with anti-static material) Stopper : Styrene-Elastomer Package method MAX. 100pcs of products shall be packaged in a sleeve. Both ends shall be closed by tabbed and tabless stoppers. The product shall be arranged in the sleeve with its anode mark on the tabless stopper side. MAX. 50 sleeves in one case. Sleeve outline dimensions (Unit : mm) S2S4 Series Sheet No.: D2-A06601EN
- Tape and Reel package 1. 3 000pcs/reel Package materials Carrier tape : A-PET (with anti-static material) Cover tape : PET (three layer system) Reel : PS Carrier tape structure and Dimensions [Packing : 3 000pcs/reel] Reel structure and Dimensions Direction of product insertion S2S4 Series Sheet No.: D2-A06601EN A 12.0±0.3 B 5.5±0.1 C 1.75±0.1 D 8.0±0.1 E 2.0±0.1 H 7.4±0.1 I 0.3±0.05 J 3.1±0.1 K 4.0±0.1 F 4.0±0.1 G φ1.5+0.1 −0 FE I D JGB A C H MAX. K H Dimensions List (Unit : mm) a c e g f b d a 370 b 13.5±1.5 c 80±1.0 d 13±0.5 e 21±1.0 f 2.0±0.5 g 2.0±0.5 Dimensions List (Unit : mm) Pull-out direction
- 750pcs/reel Package materials Carrier tape : A-PET (with anti-static material) Cover tape : PET (three layer system) Reel : PS Carrier tape structure and Dimensions [Packing : 750pcs/reel] Reel structure and Dimensions Direction of product insertion S2S4 Series Sheet No.: D2-A06601EN A 12.0±0.3 B 5.5±0.1 C 1.75±0.1 D 8.0±0.1 E 2.0±0.1 H 7.4±0.1 I 0.3±0.05 J 3.1±0.1 K 4.0±0.1 F 4.0±0.1 G φ1.5+0.1 −0 FE I D JGB A C H Dimensions List (Unit : mm) MAX. K H a 180 b 13.5±1.5 c 80±1.0 d 13±0.5 e 21±1.0 f 2.0±0.5 g 2.0±0.5 Dimensions List (Unit : mm) a c e g f b d Pull-out direction
- The circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any problems rela- ted to any intellectual property right of a third party re- sulting from the use of SHARP's devices.
- Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP reserves the right to make changes in the spec- ifications, characteristics, data, materials, structure, and other contents described herein at any time without notice in order to improve design or reliability. Manufac- turing locations are also subject to change without no- tice.
- Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used specified in the relevant specification sheet nor meet the following conditions: (i) The devices in this publication are designed for use in general electronic equipment designs such as: --- Personal computers --- Office automation equipment --- Telecommunication equipment [terminal] --- Test and measurement equipment --- Industrial control --- Audio visual equipment --- Consumer electronics (ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection with equipment that requires higher reliability such as: --- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.) --- Traffic signals --- Gas leakage sensor breakers --- Alarm equipment --- Various safety devices, etc. (iii) SHARP devices shall not be used for or in connec- tion with equipment that requires an extremely high lev- el of reliability and safety such as: --- Space applications --- Telecommunication equipment [trunk lines] --- Nuclear power control equipment --- Medical and other life support equipment (e.g., scuba).
- If the SHARP devices listed in this publication fall with- in the scope of strategic products described in the For- eign Exchange and Foreign Trade Law of Japan, it is necessary to obtain approval to export such SHARP de- vices.
- This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be repro- duced or transmitted in any form or by any means, elec- tronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party.
- Contact and consult with a SHARP representative if there are any questions about the contents of this pub- lication. ■ Important Notices S2S4 Series Sheet No.: D2-A06601EN