Features
/K6C High position resolution /K6C Wide spectral response range /K6C High-speed response /K6C Simultaneous measurements of position and intensity /K6C Position is measured independent of light-spot size /K6C High reliability
Applications
/K6C Optical position and angle sensing /K6C Remote optical control systems /K6C Automatic range finder systems /K6C Displacement and vibration monitors /K6C Laser beam alignment /K6C Medical equipment PSD Two-dimensional PSD Non-discrete position sensor utilizing photodiode surface resistance S1880, S2044 I General ratings / Absolute maximum ratings Parameter Symbol S1880 S2044 Unit Package - Ceramic Metal - Active area size - 12 × 12 4.7 × 4.7 mm Reverse voltage V R Max. 20 V Operating temperature Topr -10 to +60 °C Storage temperature Tstg -20 to +80 °C I Electrical and optical characteristics (Typ. Ta=25 °C, unless otherwise noted) Spectral response range λ - 320 to 1060 -- 320 to 1060 -n m Peak sensitivity wavelength λp - 920 - - 920 - nm Photo sensitivity S λ=λp- 0 . 6 - - 0 . 6 - A / W Interelectrode resistance *1 Rie Vb=1 V 5 10 15 5 10 15 kΩ ZONE A - ±80 ±150 - ±40 ±100Position detection error *2 ZONE B E - ±150 ±250 - ±70 ±150 µm Saturation current Ist VR=5 V Dark current I D VR=5 V - 1.0 500 - 0.5 5 nA Temp. coefficient of ID TCID - 1.15 - - 1.15 - times/°C Rise time tr VR=5 V Terminal capacitance Ct VR=5 V f=10 kHz - 300 - - 45 - pF Position resolution *3 -- 1 . 5 - - 0 . 6 - µ m *1: Measured between two output terminals opposite to each other, and the other terminals are open-circuited on measurement. *2: The radius of Zones A and B depend on the product type. They are determined as follws: Type No. ZONE A (mm) ZONE B (mm) S1880 2.5 5 S2044 0.9 4 × 4 (quadrate) KPSDC0063EA ACTIVE AREA ZONE B ZONE A
Two-dimensional PSD S1880, S2044 *3: Position resolution This is the minimum detectable light spot displacement. The detection limit is indicated by distance on the photosensitive surface. The numerical value of the resolution of a position sensor using a PSD is proporional to both the length of the PSD and the noise of the measuring system (resolution deteriorates) and inversely proportional to the photocurrent (incident evergy) of the PSD (resolution improves).
- Light source: LED (900 nm) · Photocurrent: 1 µA
- Spot Light size: φ200 µm · Circuit system input noise: 1 µV (1 kHz)
- Frequency range: 1 kHz · Interelectrode resistance: Typical value (Refer to specification table.) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 200 400 600 800 1200 1000 PHOTO SENSITIVITY (A/W) WAVELENGTH (nm) QE=100 % QE=50 % I Spectral response KPSDB0013EB I Photo sensitivity temperature characteristic KPSDB0015EB I Terminal capacitance vs. reverse voltage KPSDB0074EB +2.0 +1.5 +1.0 +0.5 -0.5 300 400 500 600 700 800 900 1000 1100 WAVELENGTH (nm) TEMPERATURE COEFFICIENT ( % /˚C) 0.1 1 10 REVERSE VOLTAGE (V) TERMINAL CAPACITANCE 1 pF 100 10 nF 1 nF 100 pF 10 pF (Typ. Ta=25 °C, f=10 kHz) S1880 S2044
Two-dimensional PSD S1880, S2044 Rf U 1 C 1 R b R b VR Rf U 2 U 3 Rf U 4 Rf R 1 R 2 R 3 R 4 R 5 R 6 R 7 R 8 U 5 R 9 U 6 R 10 U 7 R 11 U 8 R 12 R 17 R 18 R 15 R 16 R 14 R 13 R 19 U 9 R 21 U 10 R 22 U 11 R 23 ∆ X Σ 1 ∆ Y DC RESTORATION Σ 1 ∆ X Σ 1 ∆ Y U 12 U 13 R 20 C 2 C 3 R b C 4 R b R 1 - R24: same value Rf: depends on input level U 1 - U4: low drift head amplifier, TL071, etc. U 12, U13: analog divider, AD538 (Analog Devices), etc. DC RESTORATION S/H A S/H B P2 P1 ∆ X, ∆ Y, Σ 1 0 V *R1 = R2 = R3 = R4 R 1 R 2 R 4 R 3 I Example of AC-operating circuit VR Rf U 1 Rf Rf Rf U 2 U 3 U 4 R 9 R 2 R 3 R 4 R 1 R 5 R 6 R 7 R 8 U 8 U 7 U 6 U 5 R 10 R 11 R 12 R 13 R 14 R 15 R 16 R 17 R 18 R 23 R 22 R 21 R 20 U 11 U 10 U 9 R 19 U 14 U 13 R 24 R 25 U 12 - - R 1 - R25: same value Rf: depends on input level U 1 - U4: low drift head amplifier, TL071, etc. U 13, U14: analog divider, AD538 (Analog Devices), etc. I Example of DC-operating circuit KPSDC0026EB I Example of position detectability (Ta=25 °C, λ=900 nm, spot light size: φ200 µm) S2044 KPSDC0019EA LINE INTERVAL: 0.5 mm S1880 KPSDC0020EA LINE INTERVAL: 1 mm KPSDC0029EB
HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01 Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741 Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2007 Hamamatsu Photonics K.K. Cat. No. KPSD1015E06 Oct. 2007 DN Two-dimensional PSD S1880, S2044 I Dimensional outlines (unit: mm) S2044 KPSDA0012EC S1880 KPSDA0013EB 15.6 ± 0.25 5.7 5.7 14.0 ± 0.2 5.08 1.2 MAX. 2.54 5.08 5.08 5.08 4.2 5.1 ± 0.3 1.8 0.5 MAX. ACTIVE AREA 4.7 × 4.7
0.75 LEAD
ANODE (X2) ANODE (Y2) CATHODE (CASE) ANODE (X1) ANODE (Y1) X Y PHOTOSENSITIVE SURFACE (3 ×) R 0.2 9.0 ACTIVE AREA 12 × 12 0.7 t GLASS 28.0 ± 0.3 1.25 5.0 ± 0.2 9.0 10.0 9.0 9.0 ANODE (Y2) ANODE (X1) ANODE (Y1) ANODE (X2) CATHODE (COMMON) X Y PHOTOSENSITIVE SURFACE =(IX2 + IY1) - (IX1 + IY2) IX1 + IX2 + IY1 + IY2 LX =(IX2 + IY2) - (IX1 + IY1) IX1 + IX2 + IY1 + IY2 LY S1880: LX=14 mm LY=14 mm S2044: LX=5.7 mm LY=5.7 mm LX X2X1 LY x y ACTIVE AREA * * Active area is specified at the inscribed square. KPSDC0012EA I Active area chart I Position conversion formula