Technical content

Compatible with 2- and 4-wire i 3 detec- tors equipped with a sounder Activates all i3 sounders on a loop when one alarms Synchronizes all i3 sounders on the loop for a clear alarm signal Can be used with bell/alarm, alarm relay, or NAC outputs Includes a field-selectable switch to accommodate both coded and continu- ous alarm signals Allows i 3 detector silencing from the panel or keypad Operates on 12- and 24-volt systems Quick-connect harness and color coded wires facilitate connections Model RRS-MOD Reversing relay/synchronization module for i3 series sounder models Product Overview RRS-MOD System Sensor’s RRS-MOD reversing relay/synchronization module enhances the operation of 2- and 4- wire i 3 series detectors equipped with a sounder. Installation ease. The RRS-MOD includes a Velcro attachment for easy installa- tion into the fire alarm control panel cabinet. A quick-connect harness and color-coded wires simplify connections. Intelligence. The RRS-MOD’s design is flexible to accommodate virtually any application. The RRS-MOD is compatible with both 2- and 4-wire i 3 series detectors operating over 12V and 24V systems. The module can be used with either bell/alarm, alarm relay, or NAC outputs, and its field-selectable switch accommodates both coded and continuous alarm signals. Instant inspection. To meet fire alarm requirements, the RRS-MOD activates all i3 sounders on a loop when one alarms. Additionally, the RRS-MOD synchro- nizes the output of the i3 sounders, regardless of whether the panel’s alarm sig- nal is continuous or coded, to ensure a clear alarm signal. Series Reversing Relay/ Synchronization Module CONVENTIONAL DETECTION

©2002 System Sensor. The company reserves the right to change product specifications without notice. A05-0350-000•11/02•#990 EOL OPTIONAL REMOTE ANNUNCIATOR (RA400Z) OPTIONAL REMOTE ANNUNCIATOR (RA400Z) UL LISTED ALARM CONTROL PANEL 2–WIRE INITIATING DEVICE CIRCUIT PURPLE AUX POWER YELLOW IN+ ORANGE IN– RED PWR+ BLACK PWR– BROWN OUT+ WHITE OUT– 1 + IN 2 + OUT 3 - IN/OUT

4 RA+

5 RA-

(positive signal in alarm state) ALARM RELAY (NO Contact) UL LISTED ALARM CONTROL PANEL 2–WIRE INITIATING DEVICE CIRCUIT PURPLE AUX POWER YELLOW IN+ ORANGE IN– RED PWR+ BLACK PWR– BROWN OUT+ WHITE OUT– EOL OPTIONAL REMOTE ANNUNCIATOR (RA400Z) OPTIONAL REMOTE ANNUNCIATOR (RA400Z) 1 + IN 2 + OUT 3 - IN/OUT 2-Wire System Triggered from Alarm/Bell Circuit: 2-Wire System Triggered from Alarm Relay Contact: NOTE: These diagrams represent two common wiring methods. Refer to the RRS-MOD installation manual for addi- tional wiring configurations. Reversing relay/synchronization module shall be a System Sensor i3 Series model number RRS-MOD, listed to Underwriters Laboratories as a smoke detector accessory. The module shall allow all 2-wire and 4- wire i3 Series detectors equipped with a sounder on a loop to sound when one alarms. The module shall provide a switch to toggle between coded mode and continu- ous mode. When in coded mode, the mod- ule shall synchronize the i3 sounders on the loop to mirror the input signal. When in continuous mode, the module shall syn- chronize the i3 sounders on the loop to the ANSI S3.41 temporal coded pattern. In either coded or continuous modes, the RRS-MOD module shall permit sounders to be silenced at the panel. The RRS-MOD module shall operate between 8.5 and 35 VDC, and shall provide 18 AWG stranded, tinned conductors connected to a quick- connect harness. Architect/Engineer Specifications

Ordering Information

RRS-MOD Reversing relay/synchronization module for i 3 series smoke detectors Electrical Specifications Operating Voltage Avg. Operating Current Relay Contact Rating Nominal: 12 / 24 V 25mA 2 A @ 35 VDC Min.: 8.5 V Max.: 35 V Physical Specifications Operating Temperature Rangez Operating Humidity Range Wire Connections 32°F–131°F (0°C–55°C) 5% to 85% non-condensing 18 AWG stranded, tinned, 16 ″ long Dimensions Height: 2.5 inches (63 mm) Width: 2.5 inches (63 mm) Depth: 1 inch (25 mm) S0101-00 S0103-00 System Sensor Sales and Service System Sensor Headquarters

3825 Ohio Avenue

St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 Documents-on-Demand 800/736-7672 x3 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sensor in China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor – Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor – Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor – India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118