Features
- Low combined strobe/horn current draw from 90 mA
- New “Euro-Style” appearance
- Easily fits into single gang backbox
- Fits double gang backbox with optional semi-flush plate
- Multiple Light intensities –24 VDC: 15, 15/75, 75 or 110 cd models –12 VDC: 15 or 15/75 cd models
- Available in Red or White
- No measurable in-rush in excess of peak current
- Wall mount only APPROVED Specifications 1/2″31/2″ Input terminals: 18 – 12 A WG Shipping Weight: PS12/24ADA Series Strobes: 13 oz. (369g) Operating Temperature Range: 32 °F to 120°F (0°C to 49°C) Mounting: Surface: 2 ″ × 4″ × 1 1/4″ standard single gang box Semi-flush: 2 ″ × 4″ × 11/2″ standard single gang box Dimensions:
Electrical Ratings – Strobe/Mini Horn Average Operating Average Operating Peak In-rush Current in Current from Current from Full Wave Model Supply Operating Current Excess of Peak Regulated Supply Rectified, Unfiltered Supply Red White Voltage Range (mA) Operating Current (mA) (mA) (mArms)* PS2415ADA PS2415ADAW 20–30VDC 180 0 90 105 PS241575ADA PS241575ADA W 20–30VDC 220 0 108 135 PS2475ADA PS2475ADA W 20–30VDC 400 0 185 215 PS241 10ADA PS241 10ADA W 20–30VDC 500 0 225 260 PS1215ADA PS1215ADA W 10.5–17VDC 380 0 185 212 PS121575ADA PS121575ADAW 10.5–17VDC 560 0 240 285 * For additional information, see installation manual D900-08-00. Actual 12 volt operating voltage cannot be less than 8.5 VDC or greater than 18.7 VDC; actual 24 volt operating voltage cannot be less than 16 VDC or greater than 33 VDC. Standard Light Distribution Vertical Dispersion Horizontal Dispersion A polar light distribution in both horizontal and vertical directions is mandated for the strobes by the Standard UL 1971 for the Hearing Impaired, with specific minimum intensity percentages as shown in the graphs above. With its specially designed lens/reflector system, the PS12/24ADA Strobe Retrofit Plate Series meets or exceeds these requirements at all angles. LIGHT –45˚45˚ 90˚ –90˚ WALL Degree Percent of Rating 0 100 5-25 90 30-45 75 50 55 55 45 60 40 65 35 70 35 75 30 80 30 85 25 90 25 ZERO AXIS W A L L FLOOR 30354045505560657075808590˚ Degree Percent of Rating 0 100 5-30 90 35 65 40 46 45 34 50 27 55 22 60 18 65 16 70 15 75 13 80 12 85 12 90 12 Engineering Specifications Sounder/Strobe shall be a System Sensor Model ______ listed to Standard UL 1971 for the Hearing Impaired and shall be approved for Fire Protective Service. Sounder/ Strobe shall be wired as a Primary Signaling Notification appliance. Sounder/strobe shall also comply with the Americans with Disabilities Act requirements for visible signaling appliances. Sounder/Strobe shall operate on 12 or 24VDC from a regulated DC supply or full-wave rectified, unfiltered supply. The sounder/strobe shall be powered from a non-coded power supply. Sounder/Strobe shall have no measurable in-rush current in excess of operating peak current. Visual signaling devices are to be installed in all non-sleeping/corridor and sleeping areas per plans and specifications. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. All sounder/strobes shall be capable of semi-flush wall mounting to a standard 2″ × 4″ × 1 1/2″ backbox, without a separate mounting plate or to a 4″ × 4″ × 11/2″ backbox with a separate mounting plate. General Description All PS12/24ADA Series integrated sounder/strobes are suitable for primary signaling in public mode life safety applications. The sounder/strobes can be connected to the alarm indicating circuit of a UL listed fire alarm control panel. They are compatible with DC line supervision. Panels may have full-wave rectified, unfiltered power supplies. The sounder/strobes are available for either 24VDC operation, with 15, 15/75, 75, or 1 10 cd light intensity, or for 12VDC operation with 15 or 15/75 cd light intensity. They feature low current draw with no measurable in-rush in excess of peak current. The sounder/strobe is intended for wall mounting only to a 2″ electrical backbox. Mounting to a 4″ square electrical backbox can be done with the addition of the PS-FP accessory mounting plate.
4 Inch Box with Plaster
Ring and PS-FP2 Inch Box with PS-FP Sounder/Strobe
2 Inch Box 4 Inch Box with PS-FP
Note: Remove paper shield; cut and remove red and black wires between the horn and strobe. To Next Device Blk Cut and Remove for Independent Operation Red
Ordering Information
Signaling Strobe – UL 1971 Compliant Strobe and Sounder Operating Current Combined Peak Red White Product Voltage (Average mA) Candela (dBA)* PS2415ADA PS2415ADAW Signaling Strobe/Sounder 24 VDC 90 15 90 dBA PS241575ADA PS241575ADAW Signaling Strobe/Sounder 24 VDC 108 15/75 90 dBA PS2475ADA PS2475ADAW Signaling Strobe/Sounder 24 VDC 185 75 90 dBA PS24110ADA PS24110ADAW Signaling Strobe/Sounder 24 VDC 225 110 90 dBA PS1215ADA PS1215ADAW Signaling Strobe/Sounder 12 VDC 185 15 83 dBA PS121575ADA PS121575ADAW Signaling Strobe/Sounder 12 VDC 240 15/75 83 dBA PS-FP PS-FPW Semi-Flush Mounting Plate *dBA measured in anechoic room at 10 feet. **Measured to be 75 cd at 0˚ viewing angle (See Light Distribution Graph). How to Order PS1215ADAW W = White Strobe 12 = 12 Volt 24 = 24 Volt SS = Signal Strobe PS = Mini-Alert Sounder/Strobe RP = Retrofit Plate MASS = Multi-Alert Sounder/Strobe MAEH = Multi-Alert Sounder/Strobe with Electromechanical Tone V4R = 400 Series Speaker, Red SP1R = SP101 Series Speaker (Strobe), Red SP1W = SP101 Series Speaker (Strobe), White 15 = 15 cd, UL 1971 Strobe 1575 = 15 cd, UL 1971 75 = 75 cd, UL 1971 Strobe 110 = 110 cd, UL 1971 Strobe System Sensor Worldwide Distribution In Canada: System Sensor Canada
6581 Kitimat Road, Unit #7
Mississauga, Ontario Canada L5N 3T5 Telephone: 905-812-0767 Fax: 905-812-0771 In the United Kingdom: System Sensor Europe, Ltd. Horsham Gates III, North St. Horsham, West Sussex RH13 5PJ, United Kingdom Telephone: 44-1403-276500 Fax: 44-1403-276501 In India: System Sensor India A-204 Maheshwari Nagar Orkay Mills Lane Andheri East, Mumbai 400093 Telefax: 91-022-8202564 In the Far East: System Sensor Pittway Far East, Ltd. Suite 706, World Shipping Centre
7 Canton Road
Tsimshatsui, Kowloon, Hong Kong Telephone: 852-2730-9090 Fax: 852-2736-6580