Technical content

Features

  • Fits most 4 ″ or 5″ square horn or speaker
  • Multiple light intensities –24 VDC: 15,15/75, 75 or 110 cd models –12 VDC: 15 or 15/75 cd models
  • Low strobe current draw. 93 mA on the RP241575ADA with regulated power
  • Low installed cost
  • No measurable strobe in-rush in excess of peak current
  • Intended for primary signaling
  • “Installer Easy” –Plug-in terminal strip –Wire strip guage and wiring diagram on back
  • Wall mount only

Electrical Ratings – Strobe Only Average Average Operating In-rush Current in Operating Current Current from Supply Peak Operating Excess of Peak from Regulated Full Wave Rectified, Model Voltage Range Current (mA) Operating Current (mA) Supply (mA) Unfiltered Supply (mArms)* RP2415ADA 20–30VDC 180 0 75 90 RP241575ADA 20–30VDC 220 0 93 120 RP2475ADA 20–30VDC 400 0 170 200 RP241 10ADA 20–30VDC 500 0 210 245 RP1215ADA 10.5–17VDC 380 0 170 200 RP121575ADA 10.5–17VDC 560 0 225 270 * For additional information, see installation manual D900-09-00. Actual 12 volt operating voltage cannot be less than 8.5 VDC or greater than 18.7 VDC; actual 24 volt operating voltage cannot be less than 16 greater than 33 VDC. General Description The new model RP12/24ADA Series Retrofit Plate allows adding an ADA compliant visible notification appliance to most existing 4 or 5 inch square horns or speakers. All RP12/24ADA Series Strobe Retrofit Plates are suitable for primary signaling in public mode life safety applications. The Strobe Retrofit Plates can be connected to the alarm indicating circuit of a UL listed fire alarm control panel. They are compatible with DC line supervision. Panels may have full-wave rectified, unfiltered power supplies. The Strobe Retrofit Plates are available for 24VDC operation or 12VDC operation. The strobe features low current draw with no measurable in-rush in excess of peak current. The Strobe Retrofit Plate is intended for wall mounting only to a 4″ square electrical backbox.Engineering Specifications ADA Strobe Retrofit Plate shall be a System Sensor Model ______ listed to Standard UL 1971 for the Hearing Impaired and shall be approved for Fire Protective Service. The ADA Strobe Retrofit Plate series shall retrofit most 4″ or 5″ square horn or speaker into an ADA compliant visible notification device. Strobe Retrofit Plate shall be wired as a Primary Signaling Notification appliance. Strobe Retrofit Plate shall also comply with the Americans with Disabilities Act requirements for visible signaling appliances. Strobe Retrofit Plate shall operate on 12 or 24VDC from a regulated DC supply or full-wave rectified, unfiltered supply. The Strobe Retrofit Plate shall be powered from a non-coded power supply when powered with horn or speaker. Strobe Retrofit Plate shall have no measurable in-rush current in excess of operating peak current. Visual signaling devices are to be installed in all non-sleeping/corridor and sleeping areas per plans and specifications. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. All Strobe Retrofit Plates shall be capable of mounting to a standard 4″ × 4″ × 1 1/2″ backbox.

Standard Light Distribution Vertical Dispersion Horizontal Dispersion A polar light distribution in both horizontal and vertical directions is mandated for the strobes by the Standard UL 1971 for the Hearing Impaired, with specific minimum intensity percentages as shown in the graphs above. With its specially designed lens/reflector system, the RP12/24ADA Strobe Retrofit Plate Series meets or exceeds these requirements at all angles. LIGHT –45˚45˚ 90˚ –90˚ WALL Degree Percent of Rating 0 100 5-25 90 30-45 75 50 55 55 45 60 40 65 35 70 35 75 30 80 30 85 25 90 25 ZERO AXIS W A L L FLOOR 30354045505560657075808590˚ Degree Percent of Rating 0 100 5-30 90 35 65 40 46 45 34 50 27 55 22 60 18 65 16 70 15 75 13 80 12 85 12 90 12 Wiring Independent Horn/Strobe Wiring Combination Horn/Strobe Wiring (–) IN OUT STROBE ONLY (–) IN OUT (+) IN OUT STROBE ONLY (+) IN OUT From panel or previous device To Next Device or EOL – VDC + VDC (-)IN (-)OUT (+)IN (+)OUT Note: Use uncoded supply only. (–) IN OUT STROBE ONLY (–) IN OUT (+) IN OUT STROBE ONLY (+) IN OUT From panel or previous device To Next Device or EOL – VDC + VDC – VDC + VDC STROBE NON-CODED SUPPLY SOUNDER CAN BE CODED SUPPLY Mounting ADA Strobe Retrofit Plate with 5″ Speaker ADA Strobe Retrofit Plate with 4″ Horn

Ordering Information

Models – ADA Compliant, UL 1971 Listed Operating Strobe Current Strobe Retrofit Plates Description Voltage (Average mA) Candela RP2415ADA ADA Strobe Retrofit Plate 24 VDC 75 15 RP241575ADA ADA Strobe Retrofit Plate 24 VDC 93 15/75 RP2475ADA ADA Strobe Retrofit Plate 24 VDC 170 75 RP24110ADA ADA Strobe Retrofit Plate 24 VDC 210 110 RP1215ADA ADA Strobe Retrofit Plate 12 VDC 170 15 RP121575ADA ADA Strobe Retrofit Plate 12 VDC 225 15/75* *Measured to be 75 cd at 0˚ viewing angle (See Light Distribution Graph). How to Order RP1215ADAB B=Beige Strobe 12 = 12 Volt 24 = 24 Volt SS = Signal Strobe PS = Mini-Alert Sounder/Strobe RP = Retrofit Plate MASS = Multi-Alert Sounder/Strobe MAEH = Multi-Alert Sounder/Strobe with Electromechanical Tone V4R = 400 Series Speaker, Red SP1R = SP101 Series Speaker (Strobe), Red SP1W = SP101 Series Speaker (Strobe), White 15 = 15 cd, UL 1971 Strobe 75 = 75 cd, UL 1971 Strobe 110 = 110 cd, UL 1971 Strobe 1575 = 15 cd, UL 1971 System Sensor Worldwide Distribution In Canada: System Sensor Canada

6581 Kitimat Road, Unit #7

Mississauga, Ontario Canada L5N 3T5 Telephone: 905-812-0767 Fax: 905-812-0771 In the United Kingdom: System Sensor Europe, Ltd. Horsham Gates III, North St. Horsham, West Sussex RH13 5PJ, United Kingdom Telephone: 44-1403-276500 Fax: 44-1403-276501 In India: System Sensor India A-204 Maheshwari Nagar Orkay Mills Lane Andheri East, Mumbai 400093 Telefax: 91-022-8202564 In the Far East: System Sensor Pittway Far East, Ltd. Suite 706, World Shipping Centre