GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM ROOM HUMIDITY TRANSMITTER RH100B SERIES PRODUCT DESCRIPTION The RH100B series uses a highly accurate and reliable Thermoset Polymer based capacitance humidity sensor and state-of-the-art digital linearization and temperature compensated circuitry in an attractive, low profile enclosure to monitor room humidity levels. An optional temperature sensor is available. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The RH100B sensor installs directly on a standard electrical box and should be mounted five feet from the floor of the area to be controlled. Do not mount the sensor near doors, opening windows, supply air diffusers or other known air disturbances. Avoid areas where the sensor is exposed to vibrations or rapid temperature changes. A terminal is provided for connection to the Building Automation System. SENSOR TYPE Thermoset polymer based capacitive OPTIONAL TEMPERATURE SENSOR Various RTDs and thermistors available as 2 wire resistance output ACCURACY ±2, 3, or 5 %RH (5 to 95 %RH) MEASUREMENT RANGE 0 to 100 %RH RESOLUTION ±0.01 %RH HYSTERESIS ±0.8 %RH @ 25°C (77°F) SENSOR RESPONSE TIME 8 seconds STABILITY <0.25 %RH/year OPERATING TEMPERATURE 0 to 50°C (32 to 122°F) POWER SUPPLY 18 to 35 Vdc, 15 to 26 Vac CONSUMPTION 22 mA maximum OUTPUT SIGNAL 4-20 mA/0-1, 0-5 or 0-10 Vdc (field selectable) OUTPUT DRIVE @ 24 VDC Current: 550Ω max Voltage: 10,000Ω min ADJUSTMENT RH offset potentiometer, +/-10% RH ENCLOSURE White ABS, IP20 (NEMA 1) DIMENSIONS 70mm W x 114mm H x 30mm D (2.75” x 4.5” x 1.2”) TERMINATION Screw terminal block (14 to 22 AWG) COUNTRY OF ORIGIN Canada SPECIFICATIONS 31.8 mm 1.25 “ 114.3 mm 4.5 “ 82.6 mm 3.25 “ 69.85 mm 2.75“
PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-RH100BXXX-03 Greystone Energy Systems, Inc.
150 English Drive, Moncton,
New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com WIRING INFORMATION TERMINAL FUNCTION PWR 24 Vac/dc from controller or power supply COM GND or COMMON of controller OUT Analog Output TEMP Resistance Output SENSOR Resistance Output OUT COM PWR TEMP SENSOR VOLT 10V5V mA OFFSET OFFSET PRODUCT RH100B Room Humidity Transmitter ACCURACY 02 OPTIONAL TEMPERATURE SENSOR L C F E D J K M B G A 100Ω Platinum, IEC 751, 385 Alpha, thin film 1000Ω Platinum, IEC 751, 385 Alpha, thin film 1801Ω NTC Thermistor, ±0.2°C 3,000Ω NTC Thermistor, ±0.2°C 10,000Ω Type 3, NTC Thermistor, ±0.2°C 10,000Ω Type 2, NTC Thermistor, ±0.2°C 20,000Ω NTC Thermistor, ±0.2°C 1000Ω Nickel, Class B, DIN 43760 10,000Ω Type 3, NTC Thermistor, ±0.2°C c/w 11K shunt resistor 2.252KΩ Thermistor, 0.2°C ORDERING RH100B PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice.