Features
■ Extremely High Output Capability ■ Excellent Linearity ■ Superior Return Loss Performance ■ Optimal Reliability ■ Low Noise ■ Unconditionally Stable Under All Terminations ■ 27.0dB Min. Gain at 1218MHz ■ 450mA Max. at 24VDC
Applications
■ 45MHz to 1218MHz CATV Amplifier Systems ■ DOCSIS 3.1 Compliant RFPD3540
RFMD + TriQuint = Qorvo Absolute Maximum Ratings Electrical Specifications Parameter Specification Unit Condition Min Typ Max General Performance. Test conditions unless otherwise noted: V+ = 24V; TMB = 35°C; ZS = ZL = 75Ω Operating Frequency Range 45 1218 MHz Power Gain 27.0 dB f = 45MHz 27.0 28.0 29.0 dB f = 1218MHz Slope[1] 0.5 1.0 2.0 dB f = 45MHz to 1218MHz Flatness of Frequency Response 0.8 dB f = 45MHz to 1218MHz Input Return Loss -20 dB f = 45MHz to 320MHz -18 dB f = 320MHz to 640MHz -17 dB f = 640MHz to 870MHz -16 dB f = 870MHz to 1000MHz -15 dB f = 1000MHz to 1218MHz Output Return Loss -20 dB f = 45MHz to 320MHz -19 dB f = 320MHz to 640MHz -18 dB f = 640MHz to 870MHz -17 dB f = 870MHz to 1000MHz -16 dB f = 1000MHz to 1218MHz Noise Figure 5.1 5.5 dB f = 50MHz to 1218MHz Total Current Consumption (DC) 420 450 mA Parameter Rating Unit RF Input Voltage (single tone) 75 dBmV DC Supply Over-Voltage (5 minutes) 30 V Storage Temperature -40 to +100 °C Operating Mounting Base Temperature -30 to +100 °C Caution! ESD sensitive device. RoHS status based on EU Directive 2011/65/EU . Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied.
RFMD + TriQuint = Qorvo Parameter Specification Unit Condition Min Typ Max Distortion Data 40MHz to 550MHz. Test conditions unless otherwise noted: V+ = 24V; TMB = 35°C; ZS = ZL = 75Ω CTB -80 dBc VO = 59dBmV at 1218MHz, 22dB extrapolated tilt, 79 analog channels plus 111 digital channels (-6dB offset)[2][4] XMOD -76 dBc CSO -80 dBc CIN 55 dB Distortion Data 40MHz to 550MHz. Test conditions unless otherwise noted: V+ = 24V; TMB = 35°C; ZS = ZL = 75Ω CTB -76 -72 dBc VO = 58dBmV at 1218MHz, 16.5dB extrapolated tilt, 79 analog channels plus 111 digital channels (-6dB offset)[3][4] XMOD -70 -65 dBc CSO -80 -70 dBc CIN 55 58 dB 1. The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency. 2. 79 analog channels, NTSC frequency raster: 55.25MHz to 547.25MHz, +37dBmV to +46.4dBmV tilted output level, plus 111 digital channels, - 6dB offset relative to the equivalent analog carrier. 6dB offset relative to the equivalent analog carrier. 4. Composite Second Order (CSO) - The CSO parameter (both sum and difference products) is defined by ANSI/SCTE 6. Composite Triple Beat (CTB) - The CTB parameter is defined by ANSI/SCTE 6. Cross Modulation (XMOD) - Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the carrier being tested. Carrier to Intermodulation Noise (CIN) - The CIN parameter is defined by ANSI/SCTE 17 (Test procedure for carrier to noise).
RFMD + TriQuint = Qorvo Package Drawing (Dimensions in millimeters) 123 5 7 89 R O Q M 5 10mm0 scale B N L F A D H øG T S PJ U I E C K European Projection Nominal Min Max A 44,6 ± 0,2 44,4 44,8 B 13,6 ± 0,2 13,4 13,8 C 20,4 ± 0,5 19,9 20,9 D 8 ± 0,15 7,85 8,15 E 12,6 ± 0,15 12,45 12,75 F 38,1 ± 0,2 37,9 38,3 H 4 ± 0,2 3,8 4,2 I 25,4 ± 0,2 25,2 25,6 J UNC 6-32 - - L 27,2 ± 0,2 27,0 27,4 M 11,6 ± 0,5 11,1 12,1 O 0,25 ± 0,02 0,23 0,27 P 0,45 ± 0,03 0,42 0,48 Q 2,54 ± 0,3 2,24 2,84 R 2,54 ± 0,5 2,04 3,04 S 2,54 ± 0,25 2,29 2,79 T 5,08 ± 0,25 4,83 5,33 U 5,08 ± 0,25 4,83 5,33 Pin Name
1 Input
9 Output
Pinning: Notes:
RFMD + TriQuint = Qorvo Contact Information For the latest specifications, additional product information, worldwide sales and distribution locations: Web: www.rfmd.com Tel: 1-844-890-8163 Email: customer.support@qorvo.com For information about the merger of RFMD and TriQuint as Qorvo: Web: www.qorvo.com Important Notice The information contained herein is believed to be reliable. RFMD makes no warranties regarding the information contained herein. RFMD assumes no responsibility or liability whatsoever for any of the information contained herein. RFMD assumes no responsibility or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for RFMD products. The information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by such information. RFMD products are not warranted or authorized for use as critical components in medical, life -saving, or life -sustaining applications, or other applications where a failure would reasonably be expected to cause severe personal injury or death.