RC102P002 GIACOMINI | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com PRODUCT CODE SIZE DESCRIPTION RC102P002 Ø 8 x 1 mm Straight fitting RC102P109 Ø 20 x 2 mm RC122P109 Ø 20 x 2 mm 90° elbow fitting RC151P153 Ø 20 x 2 mm + 1 outlet Ø 8 x 1 mm Tee fitting, with single outlet RC151P163 Ø 20 x 2 mm + 2 outlet s Ø 8 x 1 mm Tee fitting, with double outlets PRODUCT CODE DESCRIPTION RC165P001 Plug for push-fitting Ø 8 x 1 mm RC165P004 Plug for push-fitting Ø 20 x 2 mm Versions and product codes Completion codes RC102P, RC122P RC151P, RC165P Datasheet 0974EN 01/2023 Plastic “push-fittings” Push-fit connection fittings, with internal gaskets in the pipe with embedded internal sleeve for pipe support. The fittings have the following advantages:
- ease of insertion into the pipe;
- effective locking systems;
- low loss of pressure;
- guarantee of fluid tightness thanks to the action of the double O-Ring;
- possibility to visually check the correct insertion of the pipe;
- do not require RC900 sleeves. RC102P002 RC102P109 RC122P109 RC151P153 RC151P163
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com Technical data
- Main connections: multilayer pipe Ø 20 x 2 mm
- Secondary connections: plastic pipe Ø 8 x 1 mm
- Transport and storage temperatures: -20÷80 °C
- Temperature range: min. -15 °C for water/glycol mixtures max. 80 °C for continuous 2 bar pressure
- Working pressures: min. 0 bar max. 8 bar for room temperature
- Burst pressure: > 25 bar Materials
- Fittings body: PA12 (polyamide 12) and PA 6.6 GF30 (30 % glass fiber reinforced polyamide)
- Clip: stainless steel
- O-Ring: EPDM peroxide Fitting features and components MAIN CONNECTION - PIPE Ø 20 x 2 mm
1 Pipe sleeve
2 Spacer (orange ring)
3 Double O-Ring
4 Clip
SECONDARY CONNECTION - PIPE Ø 8 x 1 mm
5 Sealing cap
6 Double O-Ring
7 Spacer (orange ring) and clip
8 Sealing O-Ring on cap
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com Pipe installation on main connections (multilayer Ø 20 x 2 mm) WARNING. Immediately stop installation if:
- the pipe cannot be inserted without forcing it
- insertion forces are not those included in the given ranges
- the pipe cannot be inserted to the length required Once installation has been completed, it is recommended to test the system as described in Giacomini datasheet 0415EN. WARNING. Fittings must be disassembled for disconnection purposes only by trained personnel. The installation is irreversible. 1) Cut the multilayer pipe perpendicularly to its axis using a dedicated pipe cutter. 2) Process the pipe end, creating a double chamfer (inner and outer) and a non-oval internal diameter within tolerance using a calibration/flaring tool. 3) Insert the pipe up to the stop on the fitting. For Ø 20: insertion force = 6÷16 kg Pipe installation on secondary connections (Ø 8 x 1 mm) WARNING. Fittings must be disassembled for disconnection purposes only by trained personnel. The installation is irreversible. WARNING. Immediately stop installation if:
- the pipe cannot be inserted without forcing it
- insertion forces are not those included in the given ranges
- the pipe cannot be inserted to the length required 1) Cut the multilayer pipe perpendicularly to its axis using a dedicated pipe cutter. 2) Insert the pipe up to the stop on the fitting. For Ø 8: insertion force = 4÷8 kg
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com Product specifications RC-P fittings Plastic push-fittings (straight, elbow 90°, Tee), with internal gaskets in the pipe with embedded internal sleeve for pipe support. PA12 (polyamide 12) and PA 6.6 GF30 (30 % glass fiber reinforced polyamide) body. Stainless steel clip. O-Ring in peroxide EPDM. Main connections: multilayer pipe Ø 20 x 2 mm. Secondary connections (if any): pipe Ø 8 x 1 mm. Temperature range: min -15 °C for water/glycol solutions; max 80 °C for continuous 2 bar pressure. Working pressures: min. 0 bar; max. 8 bar for room temperature. Burst pressure > 25 bar. Dimensions PRODUCT CODE A [mm] B [mm] ØA [mm] ØB [mm] RC102P109 67 31 (pipe stop) 9,5 20 ØB ØA A B B RC102P109 PRODUCT CODE A [mm] ØA [mm] ØB [mm] RC102P002 45 8 20 A ØB ØA RC102P002 PRODUCT CODE A [mm] B [mm] C [mm] Ø [mm] RC122P109 52,5 31 (pipe stop) 42,5 20 RC122P109 Ø A C B A C B PRODUCT CODE A [mm] B [mm] C [mm] D [mm] ØA [mm] ØB [mm] RC151P153 73 31 (pipe stop) 50 40 23,5 20 RC151P153 A B B ØB ØA D C RC165P001 C B A PRODUCT CODE A [mm] B [mm] C [mm] RC165P001 8 19 35 RC165P004 20 35,5 45 RC165P004 B A C RC151P163 A B B D C ØB ØA PRODUCT CODE A [mm] B [mm] C [mm] D [mm] ØA [mm] ØB [mm] RC151P163 99 31 (pipe stop) 50 40 23,5 20 Package Disposal. Carton boxes: paper recycling. Plastic bags and bubble wrap: plastic recycling. Product Disposal. Do not dispose of product as municipal waste at the end of its life cycle. Dispose of product at a special recycling platform managed by local authorities or at retailers providing this type of service. Safety Warning. Installation, commissioning and periodical maintenance of the product must be carried out by qualified operators in compliance with national regulations and/or local standards. A qualified installer must take all required measures, including use of Individual Protection Devices, for his and others’ safety. An improper installation may damage people, animals or objects towards which Giacomini S.p.A. may not be held liable. Additional information. For more information, go to giacomini.com or contact our technical at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force.