Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923111 - giacomini.com PRODUCT CODE CONNECTIONS R147NY004 G 3/4”F x G 3/4”F  Versions and product codes  Technical data Performance

  • Fluids: water, glycol solutions (max. 50 %)
  • Max. working temperature: 120 °C
  • Max. working pressure: 10 bar
  • Max. differential pressure: 60 kPa
  • Calibration positions: from 1 to 6 m.w.c. Materials
  • Body: CW617N - UNI EN 12165 brass
  • Spring: stainless steel AISI 302
  • Seals: EPDM
  • Knob: ABS R147N Datasheet 0126EN  07/2024 By-pass differential pressure valve The differential pressure valve R147N can be used on various types of hydrothermal systems (radiators, fan coils, radiant systems) in which the presence of thermostatic or thermo-electric actuators, or motorized zone valves, can lead to situations of simultaneous closure of all the circuits. In these conditions, the absence of a specific differential pressure valve and/or the absence of a specific control for the pump automatic switch off, can cause annoying noises in the system and may even lead to damage of the pump itself. In fact, in the phase in which the actuators are to close the respective circuits (or zones), a progressive decrease in the flow rate occurs, with a consequent increase in pressure downstream of the pump. By calibrating the differential pressure valve the system pressure can be maintained at a constant level even when the actually required flow rate changes.

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923111 - giacomini.com  Main features Wide adjustment range for possibility of installation on systems of various capacities. Additional 1/ 4” connection for possible installation of an air vent valve (to be ordered separately), which allows periodic venting of any pockets of air that, accumulating in the valve, could alter its operation. The differential by-pass valve should be used to discharge flow rates up to 1000 l/h; if higher flow rates are to be by-passed, it is advisable to opt for the installation of several valves installed in parallel configuration.  Installation The differential pressure valve R147N must be always installed downstream of the pump in between the supply and return pipes, the same versatility allows installation in both horizontal and vertical position respecting the flow direction marked on the body itself of the valve. The differential pressure valve R147N can be installed as an independent component both in the boiler room as well as in the distribution substations (manifold cabinets) and as a component for preassembled boiler units or distribution manifolds for radiant system.

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923111 - giacomini.com  Setting The calibration operation can be done by turning the knob. The presence of a graduated scale (1 to 6 meters of water gauge) allows the calibration to the desired value. The determination of the correct calibration position can be done in two ways: one practical and the other theoretical. The theoretical method is based on two characteristic of the system. The total flow (Q1) and pressure drop, through which we proceeded to the choice of the circulation pump. Through the characteristic curve of operation of the circulation pump is indentifi ed the prevalence value (P2) corresponding to a flow (Q2), equal to 15 ÷ 20% of design flow rate. The determined prevalence (P2) corresponds to the intervention pressure of the differential pressure valve which should therefore be calibrated. The practical method is brisk but not less eff ective. It consists of, in the case of boiler room manifolds, reducing the flow rate of the installation by using a ball valve in the middle, positioned downstream of the R147N connection part, closing it for about 80% and gradually opening up to cause the diff rential valve opening (this is noticeable by listening to the noise in the piping or feeling the heat of the drain pipe). After the calibration is done, it is possible to re-open the ball valve restoring the operation of the system. Q1 Flow rate of the pump during normal operation P1 Pressure of the pump during normal operation F System operation point Q2 Flow rate equal to 15÷20% of Q1 P2 Opening pressure of the differential pressure valve P Q1Q2 F Q Diagram 1 The diagram represents the trend of the differential pressure depending on the by-passed flow rate for each of the setting positions. Flow [l/h] 0 500 1000 1500 2000 2500 pos.1 pos.2 pos.3 pos.4 pos.5 pos.6 ∆p [kPa] Diagram 2

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923111 - giacomini.com PRODUCT CODE A x B C [mm] D [mm] E [mm] G [mm] H [mm] F [mm] I [mm] L [mm] R147NY004 G 3/4”F x G 3/4”F 54 25 29 24 67÷84 91÷108 31 16  Dimensions J G H F A D C E B L  Product specifications R147N By-pass differential pressure valve for HVAC systems. Connections G 3/ 4”F x G 3/ 4”F . Fluids: water, glycol solutions (max.  Package Disposal. Carton boxes: paper recycling. Plastic bags and bubble wrap: plastic recycling.  Product Disposal. Do not dispose of product as municipal waste at the end of its life cycle. Dispose of product at a special recycling platform managed by local authorities or at retailers providing this type of service.  Safety Warning. Installation, commissioning and periodical maintenance of the product must be carried out by qualified operators in compliance with national regulations and/or local standards. A qualified installer must take all required measures, including use of Individual Protection Devices, for his and others’ safety. An improper installation may damage people, animals or objects towards which Giacomini S.p.A. may not be held liable.  Additional information. For more information, go to giacomini.com or contact our technical at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force.