Quick Detection of Flame from Distance, Compact UV Sensor with High Sensitivity and Wide Directivity, Suitable for Flame Detectors and Fire Alarms. G Flame detectors for gas/oil lighters and matches G Fire alarms G Arson watch monitors G Combustion monitors for burners G Inspection of ultraviolet leakage G Detection of discharge G Ultraviolet switching Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2007 Hamamatsu Photonics K.K. Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.

APPLICATIONS

FLAME SENSOR UV TRON ® R9454, R9533 Left: R9533 Right: R9454 The UV TRON R9533 and R9454 are UV sensors that utilize the photo- electric effect from metal and gas multiplication. These devices are sensi- tive only to UV light in a spectral range of 185 nm to 260 nm. This makes them easy to use since they do not require optical visible-cut filters. Their electrodes are optimized for ruggedness to resist mechanical shocks up to 10 times (10000 m/s 2) greater than the conventional UV TRONs. The R9533 is a head-on type (UV light enters through the top of the bulb) that easily installs into equipment. The R9454 is a side-on type (UV light enters through the side of the bulb) whose outer appearance resembles the conventional flame sensor R2868. Both these types util- ize a plate cathode and feature high sensitivity and a wide field of view (directivity). GENERAL MAXIMUM RATINGS CHARACTERISTICS (at 25 °C) 1This is the maximum momentary current that can be handled if its full width at half maximum is less than 10 µs. 2If the tube is operated near this or higher, the service life is noticeably reduced. Use the tube within the recommended current values. 3Measured under room illuminations (approximately 500 lux) and recommended operating conditions. Note that these values may incr ease if the following environmental factors are present. 1. Mercury lamps, sterilization lamps, or halogen lamps are located nearby. 2. Direct or reflected sunlight is incident on the tube. 4These are representative values for a wavelength of 200 nm and a light input of 10 pW/cm 2. In actual use, the sensitivity will vary with the wavelength of the ultraviolet radiation and the drive circuitry employed. NOTE: Parameter Parameter Parameter Spectral Response Window Material Weight Supply Voltage (DC) Peak Current Average Discharge Current 2 Operating Ambient Temperature Discharge Starting Voltage (with UV radiation) (DC) Recommended Operating Voltage (DC) Background Sensitivity 4 Max. Max. Typ. Approx. 2.5 185 to 260 UV glass R9533 Approx. 1.5 R9454 400 -20 to +125 R9533 500 -20 to +60 R9454 280 350 ± 25 10000 R9533 360 400 ± 25 4000 R9454 Unit nm g Unit V mA mA Unit V V min min-1

FLAME SENSOR UV TRON ® R9454, R9533 HAMAMATSU PHOTONICS K.K., Electron Tube Division 314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E -mail: info@hamamatsu.se Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: info@hamamatsu.it WEB SITE www.hamamatsu.com I PRECAUTIONS FOR USE G Ultraviolet Radiation The UV TRON itself emits ultraviolet radiation in operation. When using two or more UV TRONs at the same time in close position, care should be taken so that they do not optically interfere with each other. G Vibration and Shock These UV TRONs passed JIS C 60068-2-6 (vibration test 3.0 mm peak to peak, 200 m/s 2, 10 Hz to 2000 Hz) and JIS C 60068-2-27 (impact test 10000 m/s2, 1 ms). However, if subjected to strong mechanical shocks such as drop impacts in excess of the guaranteed values, the bulb may crack or internal electrodes may deform resulting in poor electrical characteristics. So use extreme care when handling the UV TRON. G Polarity Connect the UV TRON at the correct polarity. Reverse polarity connection will cause malfunction or breakdown. I WARRANTY The UV TRON is covered by a warranty for a period of one year after delivery. The warranty is limited to replacement of any defective tube due to defects traceable to the manufacturer. The C3704 series are flame sensor driver circuits. The C3704 has a high-voltage power supply and sig- nal processor mounted on the same PC board. It works as a flame sensor unit just by hooking up a 5 V to 30 V DC supply and connecting to the R9533. Please note that the R9533 lead pins cannot be sol- dered directly to the C3704. A dedicated socket (E678-8F) must be used to make the connection. See the C3704 series data sheet for detailed infor- mation. UV TORON DRIVING CIRCUIT C3704 SERIES (Sold Separatery)

RELATED PRODUCTS