Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923111 - giacomini.com PRODUCT CODE CONNECTION R66AX000 G 1/8”M R66AX001 G 1/4”M R66AX002 G 3/8”M R66AX003 G 1/2”M  Versions and product codes  Technical data Materials

  • Chrome-plated brass body
  • PTFE gaskets
  • Plastic handwheel, high resistance. Technical characteristics
  • Fluids of use: water, glycol solutions (max. 50 % of glycol)
  • Temperature range: 5÷95 °C
  • Max. working pressure: 10 bar R66A Datasheet 0320EN  12/2023 Manual air vent valve for radiators Manual air vent valve for radiators. It has been designed to allow the fast and safe vent of the air from the heat sources and from the systems, where there are accumulation points that involve circulation problems. Its features permit the use also in those cases when you need to make a spillage of liquids or emptying out equipment installed on the systems. The gasket that is preassembled on the valve facilitates the assembly operations, that do not require the addition of seal materials on the threads. The manual handwheel (equipped with opening stroke- end stop that prevents the disassembling) is made of high resistance synthetic material, characterised by low thermal conductivity that confer dimensional stability with consequent excellent keeping of the manoeuvrability to the various working temperatures.

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923111 - giacomini.com  Product specifications R66A Manual air vent valve for radiators, with self-sealing gaskets in PTFE. Fluids of use: water, glycol solutions (max. 50 % of glycol).  Package Disposal. Carton boxes: paper recycling. Plastic bags and bubble wrap: plastic recycling.  Product Disposal. Do not dispose of product as municipal waste at the end of its life cycle. Dispose of product at a special recycling platform managed by local authorities or at retailers providing this type of service.  Safety Warning. Installation, commissioning and periodical maintenance of the product must be carried out by qualified operators in compliance with national regulations and/or local standards. A qualified installer must take all required measures, including use of Individual Protection Devices, for his and others’ safety. An improper installation may damage people, animals or objects towards which Giacomini S.p.A. may not be held liable.  Additional information. For more information, go to giacomini.com or contact our technical at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force.  Dimensions Bmax Ø A PRODUCT CODE A Bmax [mm] Ø [mm] R66AX000 G 1/8”M 32 17 R66AX001 G 1/4”M 33 17 R66AX002 G 3/8”M 35 17 R66AX003 G 1/2”M 35 17