Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com R553D Datasheet 0106EN 10/2023 Pre-assembled brass manifold Technical data Performance
- Temperature range: 5÷110 °C
- Max. working pressure: 10 bar
- Outlets center distance: 50 mm Materials
- Manifold: brass
- Gaskets: EPDM
- Brackets: galvanized steel ∆P [mm H2O] Q [l/h]10 50 100 500 1000 100 500 1000 0,25 0,5 0,75 1,5 2 2,5 3 4 5 F.O. Pressure loss of single circuit N° of lockshield turns 0,25 0,5 0,75 1 1,5 2 2,5 3 4 5 F. O Kv 0,06 0,10 0,14 0,17 0,21 0,28 0,37 0,55 0,85 1,20 1,33 The R553D preassembled manifold consists of:
- Supply manifold with front balancing lockshield valves equipped with mechanical memory.
- Return manifold with interception valves with manual handwheel, suitable for thermo-electric command.
- Metal brackets R588Z.
- Set of adhesive labels for identifying the various circuits.
- Spanner R558
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com Versions and product codes PRODUCT CODE CONNECTIONS MANIFOLD x OUTLETS N° OF OUTLETS CABINET * R553ZY002 1” x B.18 R500Y111 R500Y221 R500Y215 R553ZY003 3 R500Y111 R500Y221 R500Y215 R553ZY004 4 R500Y112 R500Y222 R500Y215 R553ZY005 5 R500Y112 R500Y222 R500Y215 R553ZY006 6 R500Y112 R500Y222 R500Y215 R553ZY007 7 R500Y112 R500Y222 R500Y215 R553ZY008 8 R500Y113 R500Y223 R500Y217 R553ZY009 9 R500Y113 R500Y223 R500Y217 R553ZY010 10 R500Y113 R500Y223 R500Y217 R553ZY011 11 R500Y114 R500Y224 R500Y218 R553ZY012 12 R500Y114 R500Y224 R500Y218 R553ZY022 1-1/4” x B.18 R500Y111 R500Y221 R500Y215 R553ZY023 3 R500Y111 R500Y221 R500Y215 R553ZY024 4 R500Y112 R500Y222 R500Y215 R553ZY025 5 R500Y112 R500Y222 R500Y215 R553ZY026 6 R500Y112 R500Y222 R500Y215 R553ZY027 7 R500Y112 R500Y222 R500Y215 R553ZY028 8 R500Y113 R500Y223 R500Y217 R553ZY029 9 R500Y113 R500Y223 R500Y217 R553ZY030 10 R500Y113 R500Y223 R500Y217 R553ZY031 11 R500Y114 R500Y224 R500Y218 R553ZY032 12 R500Y114 R500Y224 R500Y218 PRODUCT CODE CONNECTIONS MANIFOLD x OUTLETS N° OF OUTLETS CABINET * R553ZY042 1” x 3/4”E R500Y111 R500Y221 R500Y215 R553ZY043 3 R500Y111 R500Y221 R500Y215 R553ZY044 4 R500Y112 R500Y222 R500Y215 R553ZY045 5 R500Y112 R500Y222 R500Y215 R553ZY046 6 R500Y112 R500Y222 R500Y215 R553ZY047 7 R500Y112 R500Y222 R500Y215 R553ZY048 8 R500Y113 R500Y223 R500Y217 R553ZY049 9 R500Y113 R500Y223 R500Y217 R553ZY050 10 R500Y113 R500Y223 R500Y217 R553ZY051 11 R500Y114 R500Y224 R500Y218 R553ZY052 12 R500Y114 R500Y224 R500Y218 *NOTE. The cabinet is chosen keeping in consideration the size of the R554D intermediate fitting and R259D ball valve. SERIES PRODUCT CODE CABINETS DIMENSIONS (L x H x D) [mm] R500-1 (flush- mounting) R500Y111 400 x 460 x 110 R500Y112 600 x 460 x 110 R500Y113 800 x 460 x 110 R500Y114 1000 x 460 x 110 R500-2 (flush- mounting) R500Y221 400 x 650÷740 x 85÷130 R500Y222 600 x 650÷740 x 85÷130 R500Y223 800 x 650÷740 x 85÷130 R500Y224 1000 x 650÷740 x 85÷130 R500Y225 1200 x 650÷740 x 85÷130 R500-2E (flush with the wall) R500Y215 500 x 450 x 80÷110 R500Y217 700 x 450 x 80÷110 R500Y218 850 x 450 x 80÷110 Flush-mounting cabinets for manifolds
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com Components Manifold The supply manifold consists of a drawn brass bar in a special alloy, containing a balancing lockshield with mechanical memory for each circuit so that the calibration position in each one can be identified and maintained, even in the case of total interception. The mechanical memory takes the form of a specific ring which, when regulated with the R558 spanner, limits the maximum opening of the lockshield to the value selected during the balancing phase. To make the correct adjustment, fully open the metal ring using the screwdriver part of the R558 spanner, then close the lockshield valve fully down using the hexagonal part of the spanner. Open the valve by the number of rotations determined via the calibration diagrams, then tighten the memory ring as far as it will go on the valve. The return manifold is equipped with interception valves with a manual handwheel, suitable for thermo-electric command via the thermo-electric actuators R478, R478M (normally open) and R473, R473M (normally closed). The actuators are assembled by releasing the handwheel on the manifolds and thereby freeing the valve connection. R588Z metallic brackets Metal supports for use in R500-1 or R500-2 flush-mounting metal cabinets and in R500-2E metallic cabinets flush with the wall. Adjustment key and adhesive labels The kit is completed with a set of adhesive labels for the detection of the various circuits and an adjusting key for adjusting the holders. R553D R592D R592D R269T 1) Install any ball valves and intermediate groups at the entrance of the manifold and the terminal groups or taps at the end of themanifold. 2) Install the manifold with the metal brackets inside the cabinet. 3) Connect the main pipes coming from the boiler room to the manifold connections and the pipes of the system to the manifold outlets. For the connection use adaptors base 18 (R178, R179 or R179AM series) or Eurocone (R178E, R179E series). 4) Install and electrically connecting any electrical actuators in place of the handwheels on the return manifold. Installation Example of application scheme with radiant floor system
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com Dimensions A O P O P R L I B I I Q C Q R ED G A L I B I I H G G G FED H F NM M C PRODUCT CODE N° OF OUTLETS G x B A [mm] C [mm] D [mm] E [mm] F [mm] H [mm] I [mm] L [mm] M [mm] N [mm] O [mm] P [mm] Q [mm] R [mm] R553ZY002 2 1” x B.18 24 24 66 208 108 378 50 50 179 49 86 81 R553ZY003 3 148 50 R553ZY004 4 198 100 R553ZY005 5 248 150 R553ZY006 6 298 200 R553ZY007 7 348 250 R553ZY008 8 398 300 R553ZY009 9 448 350 R553ZY010 10 498 400 R553ZY011 11 548 450 R553ZY012 12 598 500 R553ZY022 2 1-1/4” x B.18 24 24 66 208 104 378 50 50 179 49 88 85 R553ZY023 3 148 50 R553ZY024 4 198 100 R553ZY025 5 248 150 R553ZY026 6 298 200 R553ZY027 7 348 250 R553ZY028 8 398 300 R553ZY029 9 448 350 R553ZY030 10 498 400 R553ZY031 11 548 450 R553ZY032 12 598 500
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com PRODUCT CODE N° OF OUTLETS G x B A [mm] C [mm] D [mm] E [mm] F [mm] H [mm] I [mm] L [mm] M [mm] N [mm] O [mm] P [mm] Q [mm] R [mm] R553ZY042 2 1” x 3/4”E 24 24 62 208 108 378 50 50 179 49 86 81 R553ZY043 3 148 50 R553ZY044 4 198 100 R553ZY045 5 248 150 R553ZY046 6 298 200 R553ZY047 7 348 250 R553ZY048 8 398 300 R553ZY049 9 448 350 R553ZY050 10 498 400 R553ZY051 11 548 450 R553ZY052 12 598 500 Product specification R553D Preassembled brass manifold for HVAC systems. Center distance between the outflow points 50 mm. Temperature range 5÷110 °C. Max. working pressure 10 bar. Consisting of: supply manifold with front balancing lockshield equipped with mechanical memory. Return manifold with interception valves with manual handwheel, suitable for thermo-electric command. EPDM gaskets. R588Z metal brackets. Set of adhesive labels for identifying the various circuits. 1 adjustment key R558. Available with connection for base 18 or Eurocone adaptors. Package Disposal. Carton boxes: paper recycling. Plastic bags and bubble wrap: plastic recycling. Product Disposal. Do not dispose of product as municipal waste at the end of its life cycle. Dispose of product at a special recycling platform managed by local authorities or at retailers providing this type of service. Safety Warning. Installation, commissioning and periodical maintenance of the product must be carried out by qualified operators in compliance with national regulations and/or local standards. A qualified installer must take all required measures, including use of Individual Protection Devices, for his and others’ safety. An improper installation may damage people, animals or objects towards which Giacomini S.p.A. may not be held liable. Additional information. For more information, go to giacomini.com or contact our technical at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force.