ValVes and components for radiators Radia toRs val ves with theRmost a tic option h seRies LF RG R401H R402H R403H R415H Versions and product codesDescription The H series valves with thermostatic option are indicated in the radiator systems where it is expected the installation of thermostatic heads to control the room temperature in order to optimize the consumption. When the special worksite protection handwheel is fully closed, it is possible to exceed static pressure values of 10 bar with the system disabled. In any case, it is advised to connect the heating elements before carrying out the pressurised seal tests on the system. Valve size Thermostatic head in combination Nominal flow rate qmNH in combination with thermostatic head [kg/h] Authority “a” of the stopper 1/2” (R401HX003, R402HX003, R403HX023, R403X033) R460H 170 0,87 1/2” (R415HX003) 150 0,90 3/4” (R401H, R402H) 240 0,88 1/2” (R401HX003, R402HX003, R403HX023, R403X033) R468H 160 0,91 1/2” (R415HX003) 150 0,91 3/4” (R401H, R402H) 240 0,88 1/2” (R401HX003, R402HX003, R403HX023, R403X033) R470H 170 0,86 1/2” (R415HX003) 150 0,89 3/4” (R401H, R402H) 240 0,87 Materials
- Body and main components: UNI EN 12165 CW617N chrome plated brass
- Monobloc command stem: stainless steel
- Worksite protection handwheel: PP-H
- Gaskets: EPDM Technical data
- Fluid of use: water and glycol solutions (max. 30 %)
- Temperature range: 5÷110 °C
- Max. working pressure: 16 bar with worksite protection handwheel 10 bar in combination with thermostatic head
- Max. differential pressure with thermostatic head: 1,4 bar (1/2”); 0,7 bar (3/4”)
- Can be combined with thermostatic heads R460H, R468H, R470H (threaded ring nut M30 x 1,5 mm) Series Product code Connections Valve type R401H R401HX003 1/2” Iron pipe Angle R401HX004 3/4” R402H R402HX003 1/2” Iron pipe Straight R402HX004 3/4” R403H R403HX023 1/2” (LT) Iron pipe Double angle R403HX033 1/2” (RG) R415H R415HX003 1/2” Iron pipe Reverse angle KEYMARK (EN215) certification Product code Declared hysteresis CH Influence of the declared water temperature WH Declared response time ZH Influence of the declared differential pressure DH Control accuracy CAH Complies with Directive RT2012 Certità con variation temporelle TELL Factor VT Value VTH Energy efficiency class Classification R460HX011 0,35 K 0,9 K 26 min. 0,4 K 0,6 K 0,56 0,6 0,5 R468HX001 0,23 K 0,66 K 25 min. 0,15 K 0,2 K R470HX001 0,4 K 1,2 K 26 min. 0,55 K 0,6 K
ValVes and components for radiators Radia toRs val ves with theRmost a tic option h seRies Installation of thermostatic heads The R460H, R468H and R470H thermostatic head with threaded ring nut M30 x 1,5 mm, are installed directly on the valve body after removing the worksite protection handwheel. To remove the handwheel it is necessary to counterclockwise unscrew the upper cap and then release the handwheel by levering the base using a screwdriver. The worksite protection handwheel, however, allows the valve flow rate to be partialize: by turning it anticlockwise, the valve opens; turning it clockwise the valve closes. Warning. With thermostatic head installed on the valve body, to avoid excessive loads on the seal gasket of the thermostatic bonnet (with the resulting risk of jamming and locking) during the summer months, is is recommended to place the knob in the fully open position, as marked by the symbol . In case of malfunction of the bonnet it is possible to replace the stem O-Ring, by unscrewing the nut using an hexagonal wrench 11 mm. If the problem persists is also possible to replace the complete bonnet using the appropriate key R400. R400 Nut Stem Spring Gasket O-Ring Body BONNET The bonnet replacement with R400 key, is not possible for the following valves: R401HX004, R402HX004 Hydraulic features The data shown are obtained according to the specifications of the EN215 Standard.
- R460H in combination with the valve bodies 1/2” (R401H, R402H, R403H) S-1K S-2K F. O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R460H in abbinameno a corpi valvola 1/2” (R401H, R402H, R403H) Kv s-1k = 0,28 Kv s-2k = 0,54 Kv T .A. = 1,52 Curve s-1K s-2K F.O. Kv 0,28 0,54 1,52
- R460H in combination with the valve bodies 1/2” (R415H) S-1K S-2K F. O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R460H in abbinameno a corpi valvola 1/2” (R415H) Kv s-1k = 0,25 Kv s-2k = 0,47 Kv T .A. = 1,49 Curve s-1K s-2K F.O. Kv 0,25 0,47 1,49
- R460H in combination with the valve bodies 3/4” (R401H, R402H) Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R460H in abbinameno a corpi valvola 3/4” (R401H, R402H) Kv s-1k = 0,40 Kv s-2k = 0,76 Kv T .A. = 2,15 S-1K S-2K F. O. Curve s-1K s-2K F.O. Kv 0,40 0,76 2,15
ValVes and components for radiators Radia toRs val ves with theRmost a tic option h seRies
- R468H in combination with the valve bodies 1/2” (R401H, R402H, R403H) S-1K S-2K F. O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R468H in abbinameno a corpi valvola 1/2” (R401H, R402H, R403H) Kv s-1k = 0,27 Kv s-2k = 0,51 Kv T .A. = 1,64 Curve s-1K s-2K F.O. Kv 0,27 0,51 1,64
- R468H in combination with the valve bodies 1/2” (R415H) S-1K S-2K F. O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R468H in abbinameno a corpi valvola 1/2” (R415H) Kv s-1k = 0,25 Kv s-2k = 0,47 Kv T .A. = 1,58 Curve s-1K s-2K F.O. Kv 0,25 0,47 1,58
- R468H in combination with the valve bodies 3/4” (R401H, R402H) Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R468H in abbinameno a corpi valvola 3/4” (R401H, R402H) Kv s-1k = 0,41 Kv s-2k = 0,76 Kv T .A. = 2,15 S-1K S-2K F. O. Curve s-1K s-2K F.O. Kv 0,41 0,76 2,15
- R470H in combination with the valve bodies 1/2” (R401H, R402H, R403H) S-1K S-2K F. O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R470H in abbinameno a corpi valvola 1/2” (R401H, R402H, R403H) Kv s-1k = 0,27 Kv s-2k = 0,54 Kv T .A. = 1,42 Curve s-1K s-2K F.O. Kv 0,27 0,54 1,42
- R470H in combination with the valve bodies 1/2” (R415H) S-1K S-2K F. O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R470H in abbinameno a corpi valvola 1/2” (R415H) Kv s-1k = 0,27 Kv s-2k = 0,47 Kv T .A. = 1,42 Curve s-1K s-2K F.O. Kv 0,27 0,47 1,42
- R470H in combination with the valve bodies 3/4” (R401H, R402H) Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R470H in abbinameno a corpi valvola 3/4” (R401H, R402H) Kv s-1k = 0,41 Kv s-2k = 0,76 Kv T .A. = 2,12 S-1K S-2K F. O. Curve s-1K s-2K F.O. Kv 0,41 0,76 2,12
ValVes and components for radiators Radia toRs val ves with theRmost a tic option h seRies Dimensions R401H I B L M W H G J K G x B H [mm] I [mm] J [mm] K [mm] L [mm] M [mm] W [mm] 1/2”x1/2” 61 59 27 27 76 34 30 3/4”x3/4” 65 66 29 32 85 34 37 R402H I L M H B W G J K G x B H [mm] I [mm] J [mm] K [mm] L [mm] M [mm] W [mm] 1/2”x1/2” 53 62 17 27 94 34 30 3/4”x3/4” 62 70 22 32 108 34 37 R403H I L M W G J H B K G x B H [mm] I [mm] J [mm] K [mm] L [mm] M [mm] W [mm] 1/2”x1/2” 58 59 19 27 76 34 30 R415H M G W J H B L IK G x B H [mm] I [mm] J [mm] K [mm] L [mm] M [mm] W [mm] 1/2”x1/2” 53 47 36 25 89 34 30 Product specifications R401H Angle valve with thermostatic option and threaded connection M30 x 1,5 mm, chrome plated, with iron pipe connection. Body and main components: UNI EN 12165 CW617N chrome plated brass. Monobloc command stem: stainless steel. Worksite protection handwheel: PP-H. Gaskets: EPDM. Fluid of use: water and glycol solutions (max. 30 %). Temperature range: 5÷110 °C. Max. working pressure: 16 bar with worksite protection handwheel; 10 bar in combination with thermostatic head. Max. differential pressure with thermostatic head: 1,4 bar (1/2”); 0,7 bar (3/4”). Can be combined with thermostatic heads R460H, R468H, R470H (M30 x 1,5 mm connection). KEYMARK (EN215) certification. R402H Straight valve with thermostatic option and threaded connection M30 x 1,5 mm, chrome plated, with iron pipe connection. Body and main components: UNI EN 12165 CW617N chrome plated brass. Monobloc command stem: stainless steel. Worksite protection handwheel: PP-H. Gaskets: EPDM. Fluid of use: water and glycol solutions (max. 30 %). Temperature range: 5÷110 °C. Max. working pressure: 16 bar with worksite protection handwheel; 10 bar in combination with thermostatic head. Max. differential pressure with thermostatic head: 1,4 bar (1/2”); 0,7 bar (3/4”). Can be combined with thermostatic heads R460H, R468H, R470H (M30 x 1,5 mm connection). KEYMARK (EN215) certification. R403H Double angle valve with thermostatic option and threaded connection M30 x 1,5 mm, chrome plated, with iron pipe connection. Body and main components: UNI EN 12165 CW617N chrome plated brass. Monobloc command stem: stainless steel. Worksite protection handwheel: PP- H. Gaskets: EPDM. Fluid of use: water and glycol solutions (max. 30 %). Temperature range: 5÷110 °C. Max. working pressure: 16 bar with worksite protection handwheel; 10 bar in combination with thermostatic head. Max. differential pressure with thermostatic head: 1,4 bar (1/2”). Can be combined with thermostatic heads R460H, R468H, R470H (M30 x 1,5 mm connection). KEYMARK (EN215) certification. R415H Reverse angle valve with thermostatic option and threaded connection M30 x 1,5 mm, chrome plated, with iron pipe connection. Body and main components: UNI EN 12165 CW617N chrome plated brass. Monobloc command stem: stainless steel. Worksite protection handwheel: PP- H. Gaskets: EPDM. Fluid of use: water and glycol solutions (max. 30 %). Temperature range: 5÷110 °C. Max. working pressure: 16 bar with worksite protection handwheel; 10 bar in combination with thermostatic head. Max. differential pressure with thermostatic head: 1,4 bar (1/2”). Can be combined with thermostatic heads R460H, R468H, R470H (M30 x 1,5 mm connection). KEYMARK (EN215) certification. Additional information For more information, go to www.giacomini.com or contact our technical assistance service: ' +39 0322 923372 6 +39 0322 923255 * consulenza.prodotti@giacomini.com The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini S.p.A. Via per Alzo, 39 - 28017 San Maurizio d’Opaglio (NO) Italy