Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com SERIES PRODUCT CODE CONNECTIONS N° OF WAYS TYPE STOPPER R291 R291Y004 G 3/4”M 2-way Tail piece in axis Piston R291Y005 G 1”M R292 R292Y004 G 3/4”M 3-way Tail piece in axis R292Y005 G 1”M R292E R292EY004 G 3/4”M Eccentric tail piece R292EY005 G 1”M  Versions and product codes Completion codes

  • R473, R473M: thermo-electric actuator with zone valves motor funcion.
  • R193K: eccentric kit pipe for installation of 3-ways valves with distribution manifolds. Zone valves are devices for shutting off the heat transfer fluid which, activated by an actuator, allow the subdivision of air conditioning systems into homogeneous sectors from the point of view of room temperature control. The R291, R292 and R292E zone valves are equipped with a piston stopper and can be of the 3-way type, equipped with an adjustable by-pass, or 2-way, which generally requires the installation of a differential valve on the main circuit. R291 R292, R292E R291, R292, R292E 2- and 3-way piston zone valves Datasheet 0373EN  03/2024

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com  Technical data Performance

  • Fluids: water, glycol solutions (max. 50 %)
  • Temperature range: 5÷110 °C
  • Max. working pressure: 10 bar
  • Maximum differential pressure: 1,3 bar Loss of pressure VALVE POSITION VALVE SIZE Kv Fully open without thermo-electric actuator 3/4” 4,9 1” 5,0 Fully open with R473/R473M thermo-electric actuator 3/4” 4,2 1” 4,4 Materials
  • Body, bonnet and nuts: UNI EN 12165 CW617N brass
  • Stem: stainless steel AISI 304
  • Gaskets: EPDM ∆p [mm H2O] Q [l/h] 4,2 4,4 4,9 5,01000 100 100 1000 10000 The attachments with cap and pipe union allow easy connection to the system, which must always be carried out according to the direction of flow indicated by the arrows printed on the bodies and by placing the valve so that the thermo-electric actuator or the electric motor are never turned downwards. Flow diagram  Installation Allowed installations

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com R193K by-pass connection kit for R292/R292E 3-way zone valves In the 3-way valves, the supply and return elements can be assembled directly (if mounted on dual manifold R587B), or through a by-pass conduit, using the Base 18 and TR18 adapter connections. R193K KIT CODE USE INSTALLATION R193Y011 Use in comnination with R292/R292E zone valves + R553D/R553F manifolds + R588 brackets + R500 cabinets Ø 18 B.18 Ø 18 R193Y021 Use in comnination with R292/R292E zone valves + R553D/R553F manifolds + R588Z brackets + R500-2 cabinets R292, R292E 3/ 4” with R193K by-pass kit ∆p [mm H2O] Q [l/h] 100 100 1000 10000 1000 10000 0,5 1 1,5 2 3 4 F.O. LOCKSHIELD OPENING TURNS Kv 0,5 0,3 1 0,6 1,5 0,9 2 1,3 3 1,8 4 2,1 F.O. 2,2 R292, R292E 1” with R193K by-pass kit LOCKSHIELD OPENING TURNS Kv 0,5 0,3 1 0,6 1,5 0,9 2 1,3 3 1,9 4 2,2 F.O. 2,3 ∆p [mm H2O] Q [l/h] 100 100 1000 10000 1000 10000 0,5 1 1,5 2 3 4 F.O.  NOTE. The lockshield valve on the by-pass conduit must be adjusted using an 8 mm Allen key, to reproduce a pressure drop comparable to that of the system and to avoid hydraulic failure in the distribution when the flow is deviated on the return to the boiler.

PRODUCT CODE CONNECTIONS, G H [mm] L [mm] A [mm] B [mm] H1 [mm] A1 [mm] R291Y004 G 3/4”M 88 125 49 39 133 94 R291Y005 G 1”M 88 125 49 39 133 94  Dimensions R291 L = = G A H B R291 + R473/R473M L = = G B PRODUCT CODE CONNECTIONS, G H [mm] L [mm] A [mm] I [mm] B [mm] H1 [mm] A1 [mm] R292Y004 G 3/4”M 138 125 49 55 34 183 94 R292Y005 G 1”M 138 125 49 55 34 183 94 R292 L = = G B I H A R292 + R473/R473M L = = G B I PRODUCT CODE CONNECTIONS, G H [mm] L [mm] A [mm] I [mm] E [mm] B [mm] H1 [mm] A1 [mm] R292EY004 G 3/4”M 138 125 49 55 5 34 183 94 R292EY005 G 1”M 138 125 49 55 5 34 183 94 R292E L = = G E B I H A R292E + R473/R473M L = = G E B I

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com  Product specifications R291 2-way zone valve, made of brass. G 3/4”M or G1”M connections with tail piece in axis. Fluids: water, glycol solutions (max. 50 %). Temperature range: 5÷110 °C. Max. working pressure: 10 bar. Can be motorized through the installation of R473, R473M thermo-electric actuators. R292 3-way zone valve, made of brass. G 3/4”M or G1”M connections with tail piece in axis. Fluids: water, glycol solutions (max. 50 %). Temperature range: 5÷110 °C. Max. working pressure: 10 bar. Can be motorized through the installation of R473, R473M thermo-electric actuators. R292E 3-way zone valve, made of brass. G 3/ 4”M or G1”M connections with eccentric tail piece. Fluids: water, glycol solutions (max. 50 %). Temperature range: 5÷110 °C. Max. working pressure: 10 bar. Can be motorized through the installation of R473, R473M thermo-electric actuators.  Package Disposal. Carton boxes: paper recycling. Plastic bags and bubble wrap: plastic recycling.  Product Disposal. Do not dispose of product as municipal waste at the end of its life cycle. Dispose of product at a special recycling platform managed by local authorities or at retailers providing this type of service.  Safety Warning. Installation, commissioning and periodical maintenance of the product must be carried out by qualified operators in compliance with national regulations and/or local standards. A qualified installer must take all required measures, including use of Individual Protection Devices, for his and others’ safety. An improper installation may damage people, animals or objects towards which Giacomini S.p.A. may not be held liable.  Additional information. For more information, go to giacomini.com or contact our technical at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force.