R553FSX242 GIACOMINI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com R553FS Datasheet 0939EN  02/2025 Preassembled stainless steel manifold kit  Technical data Performance

  • Temperature range 5÷70 °C
  • Max. working pressure: 6 bar (10 bar for system pressure test)
  • Air vent valve max. working pressure: 10 bar
  • Center distance between manifold outlets: 50 mm Materials
  • Supply and return manifolds: AISI 304 stainless steel
  • Terminal units and drain cock: brass
  • Gaskets: EPDM
  • Manifold brackets: galvanized steel
  • Handwheels: plastic Diagram for setting loss of pressure in single circuits N° of turns of the flow meter’s lockshield F. O. Kv 1,21 ∆P [mm H2O] Q [l/h] 100 1000 10 100 1000 F.O. R553FS stainless steel preassembled manifold kit for HVAC systems, including:
  • supply manifold with flow meters (double scale 0÷5 l/min and 0÷1,5 GPM) working as balancing lockshields;
  • return manifold with shut-off valves for thermo-electric control thanks to the M30 x 1,5 mm standard connection; handwheels included;
  • pair of terminal units with drain cocks, manual air vent valves and R74 special control wrench;
  • electro-galvanized steel brackets for cabinet or wall- mounting installation.

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com  Versions and product codes PRODUCT CODE CONNECTIONS: MANIFOLD x OUTLETS No. OUTLETS CABINET R500-2 L x H x D R553FSX242 1”F x 3/4”E R500Y221 400x650x85÷130 mm R553FSX243 3 R553FSX244 4 R500Y222 600x650x85÷130 mm R553FSX245 5 R553FSX246 6 R553FSX247 7 R553FSX248 8 R500Y223 800x650x85÷130 mm R553FSX249 9 R553FSX250 10 R553FSX251 11 R500Y224 1000x650x85÷130 mm R553FSX252 12 Optional components

  • R500-2: flush-mounting metal cabinet, with adjustable depth
  • R473, R473M: normally closed thermo-electric actuators
  • R453FY002: M30 x 1,5 mm plastic ring nut for installing thermo-electric actuators
  • R178E, R179E: 3/ 4”E adaptors Optional kits PRODUCT CODE CONNECTIONS R259SX077 G 1”F x G 1”M R259KX006 G 3/4”F x G 1”M R259KX007 G 1”F x G 1”M R859KX016 G 3/4”F x G 1”M R859KX017 G 1”F x G 1”M R859KX026 G 3/4”F x G 1”M R859KX027 G 1”F x G 1”M  NOTE. Manifold/cabinet combinations are applicable for manifolds with end pieces only, WITH NO optional kits installed.  Components A Supply manifold B Return manifold C Metal bracket D Flow meter working as regulation lockshield E Shut-off valve with handwheel F 3/4”Eurocone threaded fitting G Manual air vent valve H Drain cock C CD D D D F F F F F F F F E E E E G H G H A B

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com  Installation and setting  WARNING. Installation must be carried out by qualified operators according to the instructions below. Installation of terminal units First screw the intermediate fitting (A) on the manifold. Then install the drain cock (B) on the bottom of the intermediate fitting and the air vent valve (C) on top. All components are provided with self-sealing gasket. A B C Max. 25 Nm 5 Nm 5 Nm A B C Circuit pipe connection To connect the circuit water supply pipes, use Eurocone adaptors for copper, plastic or multilayer pipes series R178E or R179E.  WARNING. Use a 26 mm back wrench when screwing/unscrewing the adaptors to the manifold outlets. Setting and balancing of hydraulic circuits on supply manifold The system single circuits must be set using the flow meters as regulation lockshields on the supply manifold. For proper setting, follow the instructions below: 1) Remove the red protection cap; 2) Place the flow indicator on the desired flow rate value; 3) Set the flow rate by turning the special ring nut till the meter inner plate is on the flow rate indicator previously set; 4) Replace the red protection cap which also blocks the preset regulation. 1 2 3 4 R473 R473M R453F R473 R473M R453F R473 R473M R453F R473 R473M R453F Shutting off the hydraulic circuits on the return manifold Turn the provided blue handwheels all the way through to shut off the circuits on the return outlets. As an alternative, thermo-electric actuators can be installed on the M30 x 1,5 mm standard connection. T o install the R473/R473M thermo-electric actuators normally closed, replace the blue handwheels with R453FY002 quick-fit ring nuts. Install the thermo-electric actuator of the ring nut using enough pressure to fit it. Turn the thermo-electric actuator slightly to properly connect it to the ring nut (max. torque 5 Nm).

Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com PRODUCT CODE N° OF OUTLETS G x B A [mm] C [mm] D [mm] E [mm] F [mm] H [mm] I [mm] L [mm] M [mm] N [mm] P [mm] R [mm] S [mm] T [mm] R553FSX242 2 1”F x 3/4”E 38 102 61 209 109 379 50 190 50 197 110 49 86 35 R553FSX243 3 240 160 R553FSX244 4 290 210 R553FSX245 5 340 260 R553FSX246 6 390 310 R553FSX247 7 440 360 R553FSX248 8 490 410 R553FSX249 9 540 460 R553FSX250 10 590 510 R553FSX251 11 640 560 R553FSX252 12 690 610  Dimensions A I I L I C R S FED H B P T GG M N  Package Disposal. Carton boxes: paper recycling. Plastic bags and bubble wrap: plastic recycling.  Product Disposal. Do not dispose of product as municipal waste at the end of its life cycle. Dispose of product at a special recycling platform managed by local authorities or at retailers providing this type of service.  Safety Warning. Installation, commissioning and periodical maintenance of the product must be carried out by qualified operators in compliance with national regulations and/or local standards. A qualified installer must take all required measures, including use of Individual Protection Devices, for his and others’ safety. An improper installation may damage people, animals or objects towards which Giacomini S.p.A. may not be held liable.  Additional information. For more information, go to giacomini.com or contact our technical at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force.  Product specifications R553FS Stainless-steel preassembled manifold kit for HVAC systems. 3/ 4”Eurocone outlet circuit connections for copper, plastic or multilayer pipe adaptors. Center distance between outlets 50 mm. Temperature range 5÷70 °C. Max. Max. working pressure: 6 bar (10 bar for system pressure test). Air vent valve max. working pressure 10 bar. Includes a supply manifold with flow meters (double scale 0÷5 l/min and 0÷1,5 GPM) working as regulation lockshields for single circuits, a return manifold with shut-off valves activated by handwheels, manifold metal brackets and a pair of terminal units including manual air vent valve and drain cock. Replace the handwheel with thermo-electric actuators normally closed for automatic setting of the circuits.