Components for boiler room Dynamic balancing valves R206a Versions and product codes Product codes Connections Working flow rate [m3/h] Differential pressure working range ∆p [kPa] R206AY013 G 1/2”F 0,276 - 0,825 17 - 200 R206ANY014 G 3/4”F 0,406 - 1,270 30 - 400 R206AY015 G 1”F 0,535 - 5,830 17 - 400 R206AY016 G 1-1/4”F 0,535 - 5,830 17 - 400 R206AY017 G 1-1/2”F 3,180 - 16,100 20 - 400 R206AY018 G 2”F 3,180 - 16,100 20 - 400 R206AY033 G 1/2”F 0,100 - 0,412 17 - 210 R206ANY034 G 3/4”F 0,100 - 0,412 17 - 210 Accessories

  • P206A: spare part cartridge for R206A valves Cartridge codes R206A which is installed Cartridge colour (1) Indicator colour (2) Plug colour (3) Legend P206AY001 R206AY013 Red White Red P206AY002 R206ANY014 Red Grey Red P206AY003 R206AY015 R206AY016 Black White Green P206AY004 R206AY017 R206AY018 White Grey Black P206AY005 R206AY033 R206ANY034 Black White Black
  • P206Y001: probe holder (n.2) kit for the flow rate determination through measurement of the differential pressure, 1/4” M connections
  • R225EY001: differential pressure manometer Technical data
  • Compatible fluids: water and glycol solutions (max. 50 % of glycol)
  • Max. working temperature: 120 °C
  • Max. working pressure: 25 bar
  • Max. differential pressure: 4 bar (2 bar for R206AY013, R206AY033, R206ANY034) Materials
  • Body: brass CW617N - UNI EN 12165
  • Cartridge: PSU e PPS
  • Spring: stainless steel
  • Gaskets: EPDM Installation The R206A dynamic balancing valve should be installed on the return side of the system. It is recommended to install a filter prior the R206A valve to prevent damage or blockage due to debris. Further, it is recommended not to exceed maximum differential pressure control range of the cartridge. Note. Failure to abide by all recommendations as per this installation and operation instruction will void warranty. R206A Cartridge setting adjustment To adjust the setting of the cartridge according to the desired flow rate, proceed as follows: 1) Remove the cartridge plug; 2) Using a 8 mm wrench, rotate the stem of the cartridge clockwise to decrease the setting; counterclockwise to increase the setting; 3) Replace the cartridge plug. 1 2 3 8 mm8 mm8 mm R206A

Description

R206A balancing valves maintain a constant flow rate of the fluid as the upstream/downstream pressure difference varies. The set flow rate is guaranteed inside the declared range of differential pressure, with a maximum mistake of ± 5 % on controlled flow rate values, or ± 2 % on the maximum flow. The balancing valves automatically balance the hydraulic circuit and ensure the design flow rate. They are composed of a brass body, with female- female connections and prearranged for the connection of sensor holder, to measure the differential pressure, and they have a cartridge that can be replaced if needed. It can be calibrated through a key that compensates the differential pressure by guaranteeing the flow rate constancy. A double indicator, having 1 to 5 scale and decimal decision from 1 to 9, permits precise flow rate regulations (please refer to the “Flow rate diagrams” paragraph for the complete regulation tables for the different valve types).

Components for boiler room Dynamic balancing valves R206a Flow rate check To calculate the flow rate of the R206A, you just have to measure the differential pressure, by installing in the housings of the valve the probe holder P206Y001 and by using a differential pressure manometer. If the measured differential pressure value falls within the nominal operating range, then the flow rate through the valve corresponds to the setting set on the cartridge (see “Flow rate diagrams”). Balancing valve R206A + probe holder P206Y001 + differential pressure manometer R225E Probe Differential pressure manometer Warning. Leakage of hot water can occur through the pressure outlets during the sensor introduction of the sensors. Wear protective clothes and glasses in order to prevent personal physical damages during the pressure measure. Do not use lubricants on the sensors to ease the outlet insertion. If needed simply wet the sensors with clean water. Do not leave the measure needle too much time in the pressure outlet, as it could cause leakages. Dimensions 1/4”F CB A E D 1/4”F Product codes Connec- tion A [mm] B [mm] C [mm] D [mm] E [mm] R206AY013 G 1/2”F 82 31 78 22 36 R206ANY014 G 3/4”F 85 31 78 22 36 R206AY015 G 1/2”F 128 47 99 22 65 R206AY016 G 3/4”F 128 47 99 22 65 R206AY017 G 1/2”F 169 54,5 117 22 100 R206AY018 G 3/4”F 169 54,5 117 22 100 R206AY033 G 1/2”F 82 31 78 22 36 R206ANY034 G 3/4”F 85 31 78 22 36 Flow rate diagrams Accuracy: ± 5 % on controlled flow rate. R206AY013 - ∆p: 17-200 kPa Setting l / sec l / h 1.0 0,0767 276 1.1 0.0813 293 1.2 0.0860 310 1.3 0.0907 326 1.4 0.0953 343 1.5 0.100 360 1.6 0.105 377 1.7 0.109 393 1.8 0.114 410 1.9 0.118 426 2.0 0.123 443 2.1 0.128 459 2.2 0.132 475 2.3 0.136 491 2.4 0.141 507 2.5 0.145 523 2.6 0.150 539 2.7 0.154 554 2.8 0.158 569 2.9 0.162 584 3.0 0.166 599 3.1 0.170 614 3.2 0.174 628 3.3 0.178 642 3.4 0.182 655 3.5 0.186 669 3.6 0.189 682 3.7 0.193 695 3.8 0.196 707 3.9 0.200 719 4.0 0.203 731 4.1 0.206 742 4.2 0.209 753 4.3 0.212 764 4.4 0.215 774 4.5 0.218 784 4.6 0.220 793 4.7 0.223 802 4.8 0.225 810 4.9 0.227 818 5.0 0.229 825

Components for boiler room Dynamic balancing valves R206a R206ANY014 - ∆p: 30-400 kPa Setting l / sec l / h 1.0 0.113 406 1.1 0.119 427 1.2 0.125 449 1.3 0.131 470 1.4 0.137 492 1.5 0.143 513 1.6 0.149 535 1.7 0.155 556 1.8 0.161 578 1.9 0.167 599 2.0 0.172 621 2.1 0.178 642 2.2 0.184 664 2.3 0.190 685 2.4 0.196 707 2.5 0.202 728 2.6 0.208 750 2.7 0.214 771 2.8 0.220 793 2.9 0.226 814 3.0 0.232 836 3.1 0.238 857 3.2 0.244 879 3.3 0.250 900 3.4 0.256 922 3.5 0.262 943 3.6 0.268 965 3.7 0.274 987 3.8 0.280 1010 3.9 0.286 1030 4.0 0.292 1050 4.1 0.298 1070 4.2 0.304 1090 4.3 0.310 1120 4.4 0.316 1140 4.5 0.322 1160 4.6 0.328 1180 4.7 0.334 1200 4.8 0.340 1220 4.9 0.346 1240 5.0 0.352 1270 R206AY015, R206AY016 - ∆p: 17-400 kPa Setting l / sec l / h 1.0 0.149 535 1.1 0.220 793 1.2 0.289 1040 1.3 0.355 1280 1.4 0.418 1510 1.5 0.479 1730 1.6 0.538 1940 1.7 0.594 2140 1.8 0.647 2330 1.9 0.699 2520 2.0 0.748 2690 2.1 0.795 2860 2.2 0.841 3030 2.3 0.884 3180 2.4 0.925 3330 2.5 0.965 3470 2.6 1.00 3610 2.7 1.04 3740 2.8 1.07 3870 2.9 1.11 3990 3.0 1.14 4100 3.1 1.17 4220 3.2 1.20 4320 3.3 1.23 4420 3.4 1.26 4520 3.5 1.28 4620 3.6 1.31 4710 3.7 1.33 4800 3.8 1.36 4890 3.9 1.38 4970 4.0 1.40 5050 4.1 1.43 5130 4.2 1.45 5210 4.3 1.47 5290 4.4 1.49 5370 4.5 1.51 5440 4.6 1.53 5520 4.7 1.55 5600 4.8 1.58 5670 4.9 1.60 5750 5.0 1.62 5830

Components for boiler room Dynamic balancing valves R206a R206AY017, R206AY018 - ∆p: 20-400 kPa Setting l / sec l / h 1.0 0.883 3180 1.1 1.14 4100 1.2 1.37 4940 1.3 1.59 5710 1.4 1.78 6420 1.5 1.96 7070 1.6 2.13 7660 1.7 2.28 8200 1.8 2.42 8700 1.9 2.54 9150 2.0 2.66 9570 2.1 2.77 9960 2.2 2.86 10300 2.3 2.95 10600 2.4 3.04 10900 2.5 3.12 11200 2.6 3.19 11500 2.7 3.26 11700 2.8 3.32 12000 2.9 3.39 12200 3.0 3.45 12400 3.1 3.51 12600 3.2 3.56 12800 3.3 3.62 13000 3.4 3.67 13200 3.5 3.73 13400 3.6 3.78 13600 3.7 3.83 13800 3.8 3.89 14000 3.9 3.94 14200 4.0 3.99 14400 4.1 4.05 14600 4.2 4.10 14800 4.3 4.15 14900 4.4 4.20 15100 4.5 4.25 15300 4.6 4.30 15500 4.7 4.35 15700 4.8 4.39 15800 4.9 4.44 16000 5.0 4.48 16100 R206AY033, R206ANY034 - ∆p: 17-210 kPa Setting l / sec l / h 1.0 0.028 100 1.1 0.030 108 1.2 0.032 116 1.3 0.034 123 1.4 0.036 131 1.5 0.039 139 1.6 0.041 147 1.7 0.043 155 1.8 0.045 162 1.9 0.047 170 2.0 0.049 178 2.1 0.052 186 2.2 0.054 194 2.3 0.056 201 2.4 0.058 209 2.5 0.060 217 2.6 0.062 225 2.7 0.064 233 2.8 0.067 240 2.9 0.069 248 3.0 0.071 256 3.1 0.073 264 3.2 0.075 272 3.3 0.077 279 3.4 0.080 287 3.5 0.082 295 3.6 0.084 303 3.7 0.086 311 3.8 0.088 318 3.9 0.091 326 4.0 0.093 334 4.1 0.095 342 4.2 0.097 350 4.3 0.099 357 4.4 0.101 365 4.5 0.104 373 4.6 0.106 381 4.7 0.108 389 4.8 0.110 396 4.9 0.112 404 5.0 0.114 412 Additional information For more information, go to www.giacomini.com or contact our technical assistance service: ' +39 0322 923372 6 +39 0322 923255 * consulenza.prodotti@giacomini.com The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Giacomini S.p.A. Via per Alzo, 39 - 28017 San Maurizio d’Opaglio (NO) Italy