R16X002 GIACOMINI | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com R16, R17 Datasheet 0951EN 04/2019 Lockshields for radiators SERIES PRODUCT CODE CONNECTIONS FINISHING TYPE R16 R16X002 3/8” x 3/8” Iron pipe connection Chrome plated Angle R16X003 1/2” x 1/2” R16Y002 3/8” x 3/8” Brass finish R16Y003 1/2” x 1/2” R17 R17X002 3/8” x 3/8” Chrome plated StraightR17X003 1/2” x 1/2” R17Y003 1/2” x 1/2” Brass finish Versions and product codes Angle and straight lockshields for radiators, chrome plated brass or brass finish, iron pipe connection. Brass cap. R16 R17
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com Technical data Performance
- Fluid of use: water and glycol solutions (max. 30 %)
- Temperature range: 5÷110 °C
- Max. working pressure: 16 bar Materials
- Body, tail piece and nut: UNI EN 12165 CW617N brass
- Cap: UNI EN 12164 CW614N brass
- Gaskets: PTFE Hydraulic features R16X002, R16Y002 (3/8”) N° of opening turns of the lockshield, starting from Fully Closed position N° of turns 0,5 1 2 4 F.O. Kv 0,26 0,45 0,70 0,95 1,34 Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R16 (Kv) 3/8” POS.0,5 = 0,26 POS.1 = 0,45 POS.2 = 0,70 POS.3 = 0,94 POS.4 = 0,98 F .O. = 1,34 POS.0,5 POS.1 POS.2 POS.4F .O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R16 (Kv) 1/2” POS.0,5 = 0,35 POS.1 = 0,57 POS.2 = 0,70 POS.3 = 1,25 POS.4 = 1,56 F .O. = 2,50 POS.0,5 POS.1 POS.2 POS.4 F .O. R16X003, R16Y003 (1/2”) N° of opening turns of the lockshield, starting from Fully Closed position N° of turns 0,5 1 2 4 F.O. Kv 0,35 0,57 0,70 1,56 2,5 Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R16 (Kv) 3/8” POS.0,5 = 0,26 POS.1 = 0,45 POS.2 = 0,70 POS.3 = 0,94 POS.4 = 0,98 F .O. = 1,34 POS.0,5 POS.1 POS.2 POS.4F .O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R16 (Kv) 1/2” POS.0,5 = 0,35 POS.1 = 0,57 POS.2 = 0,70 POS.3 = 1,25 POS.4 = 1,56 F .O. = 2,50 POS.0,5 POS.1 POS.2 POS.4 F .O. R17X003, R17Y003 (1/2”) N° of opening turns of the lockshield, starting from Fully Closed position N° of turns 0,5 1 2 4 F.O. Kv 0,37 0,51 0,70 1,13 1,55 Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R17 (Kv) 3/8” POS.0,5 = 0,24 POS.1 = 037 POS.2 = 0,63 POS.4 = 0,88 F .O. = 0,96 POS.0,5POS.1 POS.2POS.4F .O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R17 (Kv) 1/2” POS.0,5 = 0,37 POS.1 = 0,51 POS.2 = 0,70 POS.3 = 0,89 POS.4 = 1,13 F .O. = 1,55 POS.0,5POS.1 POS.2 POS.4F .O. R17X002 (3/8”) N° of opening turns of the lockshield, starting from Fully Closed position N° of turns 0,5 1 2 4 F.O. Kv 0,24 0,37 0,63 0,88 0,96 Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R17 (Kv) 3/8” POS.0,5 = 0,24 POS.1 = 037 POS.2 = 0,63 POS.4 = 0,88 F .O. = 0,96 POS.0,5POS.1 POS.2POS.4F .O. Q [l/h] ∆p [mm H2O] 10 100 1000 100 1000 ∆p [kPa] 0,1 1,0 10,0 R17 (Kv) 1/2” POS.0,5 = 0,37 POS.1 = 0,51 POS.2 = 0,70 POS.3 = 0,89 POS.4 = 1,13 F .O. = 1,55 POS.0,5POS.1 POS.2 POS.4F .O.
Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia consulenza.prodotti@giacomini.com +39 0322 923372 - giacomini.com Dimensions PRODUCT CODE G x B H [mm] I [mm] J [mm] K [mm] L [mm] Y [mm] W [mm] R16X002 R16Y002 3/8” x 3/8” 35 47 18 21 59 19 27 R16X003 R16Y003 1/2” x 1/2” 41 52 21 25 66 22 30 R16 PRODUCT CODE G x B H [mm] I [mm] J [mm] K [mm] L [mm] Y [mm] W [mm] R17X002 3/8” x 3/8” 38 48 15 21 68 19 27 R17X003 R17Y003 1/2” x 1/2” 45 50 17 25 74 22 30 R17 W Y G J I L K H B WY G J H K B I L Package Disposal. Carton boxes: paper recycling. Plastic bags and bubble wrap: plastic recycling. Product Disposal. Do not dispose of product as municipal waste at the end of its life cycle. Dispose of product at a special recycling platform managed by local authorities or at retailers providing this type of service. Safety Warning. Installation, commissioning and periodical maintenance of the product must be carried out by qualified operators in compliance with national regulations and/or local standards. A qualified installer must take all required measures, including use of Individual Protection Devices, for his and others’ safety. An improper installation may damage people, animals or objects towards which Giacomini S.p.A. may not be held liable. Additional information. For more information, go to giacomini.com or contact our technical at any time, without notice and for technical or commercial reasons, the items included herewith. The information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force.