SFH2701 AMSCO | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 17
Technical content
1 Version 1.3 | 2021-09-30 Discontinued Produktdatenblatt | Version 1.1 www.osram-os.com
Applications
Industrial Automation (Machine Controls, Light Barriers, Vision Controls) Features: Package: Epoxy, diffuse ESD: 2 kV acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 2) Especially suitable for applications from 400 nm to 1050 nm Fast switching time within the specified wavelength Fast switching time at low reverse voltage (<5V) Ultra short decay time (“slow tail”) IEC Standard 3216 Chipled package
Ordering Information
Type Photocurrent 1) Photocurrent Ordering Code typ. Ee = 0.5 mW/cm²; λ = 650 nm; VR = 5 V Ee = 0.5 mW/cm²; λ = 650 nm; VR = 5 V IP IP SFH 2701 ≥ 0.9 µA 1.2 µA Q65110A2960
2 Version 1.3 | 2021-09-30 Discontinued Maximum Ratings TA = 25 °C Parameter Symbol Values Operating Temperature Top min. max. -40 °C 85 °C Storage temperature Tstg min. max. -40 °C 85 °C Reverse voltage VR max. 15 V Reverse voltage t ≤ 120 s; TA = 0 °C VR max. 20 V ESD withstand voltage acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 2) VESD max. 2 kV
3 Version 1.3 | 2021-09-30 Discontinued Characteristics TA = 25 °C Parameter Symbol Values Spectral sensitivity λ = 650 nm S typ. 0.45 A / W Spectral sensitivity λ = 780 nm S typ. 0.5 A / W Wavelength of max sensitivity λS max typ. 820 nm Spectral range of sensitivity λ10% typ. 400 ... 1050 nm Photocurrent Ee = 0.5 mW/cm²; λ = 780 nm; VR = 5 V IP typ. 1.4 µA Radiant sensitive area A typ. 0.36 mm² Dimensions of active chip area L x W typ. 0.6 x 0.6 mm x mm Distance chip front to case surface H typ. 0.3 mm Half angle φ typ. 60 ° Dark current VR = 5 V IR typ. max. 0.045 nA 5 nA Rise time VR = 5 V; RL = 50 Ω; λ = 650 nm; IP = 1 mA tr typ. 1.8 ns Rise time VR = 5 V; RL = 50 Ω; λ = 780 nm; IP = 1 mA tr typ. 2 ns Fall time VR = 5 V; RL = 50 Ω; λ = 650 nm; IP = 1 mA tf typ. 1.8 ns Fall time VR = 5 V; RL = 50 Ω; λ = 780 nm; IP = 1 mA tf typ. 2 ns Forward voltage λ = 0 nm VF typ. 0.8 V Capacitance VR = 0 V; f = 1 MHz; E = 0 C0 typ. max. 3 pF 5 pF Noise equivalent power NEP = 17.9 x 10-15 x (IR)1/2 /Sλ VR = 5 V, λ = 650 nm NEP typ. 0.009 pW / Hz1/2 Temperature coefficient of sensitivity λ = 650 nm TCI typ. -0.03 % / K Temperature coefficient of sensitivity λ = 780 nm TCI typ. -0.01 % / K
4 Version 1.3 | 2021-09-30 Discontinued Relative Spectral Sensitivity 2), 3) Srel = f (λ) OHF00815 λ relS 400 500 600 700 800 900 nm 1100 100 Directional Characteristics 2), 3) Srel = f (φ) OHF01402 40 30 20 10 20 40 60 80 100 1200.40.60.81.0 ϕ 0.2 0.4 0.6 0.8 1.0 100
5 Version 1.3 | 2021-09-30 Discontinued Dark Current 2), 3) IR = f (VR); E = 0 OHF03904 VR RI nA 0V0 0.02 0.04 0.06 0.08 0.12 5 10 15 20 Switching Time 2), 3) tr, tf = f (VR); IP = 200 µA; RL = 50 Ω; λ = 650 nm OHF03917 VR rt ns 0V0 , ft 2 4 6 8 10 12 16 Capacitance 2), 3) C = f (VR); f = 1MHz; E = 0; TA = 25°C OHF03901 RV -310 -210 -110 010 110 210V pF C
6 Version 1.3 | 2021-09-30 Discontinued Dark Current 2) IR = f (TA); E = 0; VR = 5 V OHF03831 RI 10-2 35 45 55 65 75 ˚C85 102 nA AT 110 100
7 Version 1.3 | 2021-09-30 Discontinued Dimensional Drawing 4) 1.25 (0.049) 0.92 (0.036) 0.5 (0.020) 0.9 (0.035) 0.7 (0.028) 0.4 (0.016) 1.35 (0.053) 1.65 (0.065) 3.05 (0.120) 3.35 (0.132) 1.85 (0.073) 2.15 (0.085) Center of GPLY7034 active area ø0.7 (0.028) ø0.9 (0.035) Cathode mark Further Information: Approximate Weight: 7.6 mg Package marking: Cathode Pin Description
1 Cathode
2 Anode
8 Version 1.3 | 2021-09-30 Discontinued Recommended Solder Pad 4) OHF03896 4.7 1.5 1.5
9 Version 1.3 | 2021-09-30 Discontinued Reflow Soldering Profile Product complies to MSL Level 3 acc. to JEDEC J-STD-020E 00 s OHA04525 100 150 200 250 300 50 100 150 200 250 300 t T St t Pt Tp240 ˚C 217 ˚C 245 ˚C 25 ˚C L Profile Feature Symbol Pb-Free (SnAgCu) Assembly Unit Minimum Recommendation Maximum Ramp-up rate to preheat*) 25 °C to 150 °C 2 3 K/s Time tS TSmin to TSmax tS 60 100 120 s Ramp-up rate to peak*) TSmax to TP 2 3 K/s Liquidus temperature TL 217 °C Time above liquidus temperature tL 80 100 s Peak temperature TP 245 260 °C Time within 5 °C of the specified peak temperature TP - 5 K tP 10 20 30 s Ramp-down rate* TP to 100 °C 3 6 K/s Time 25 °C to TP 480 s All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range
10 Version 1.3 | 2021-09-30 Discontinued Taping 4)
11 Version 1.3 | 2021-09-30 Discontinued Tape and Reel 5) Reel Dimensions A W Nmin W1 W2 max Pieces per PU 180 mm 8 + 0.3 / - 0.1 mm 60 mm 8.4 + 2 mm 14.4 mm 3000
12 Version 1.3 | 2021-09-30 Discontinued Barcode-Product-Label (BPL) Dry Packing Process and Materials 4) OHA00539 OSRAM Moisture-sensitive label or print Barcode label Desiccant Humidity indicator Barcode label OSRAM Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. WET Do not eat. Comparator check dot parts still adequately dry. examine units, if necessary examine units, if necessary 15% 10%bake units bake units If wet, change desiccant If wet, Humidity Indicator MIL-I-8835 If wet, M oisture Level 3 Floor tim e 168 Hours M oisture Level 6 Floor tim e 6 Hours a) Hum idity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package 2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 m onths at < 40 ˚C and < 90% relative hum idity (RH). M oisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) M ounted within b) Stored at body tem 3. Devices require baking, before m ounting, if: Bag seal date M oisture Level 1 M oisture Level 2 M oisture Level 2a4. If baking is required, b) 2a or 2b is not m et. Date and tim e opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor tim e see below If blank, see bar code label Floor tim e > 1 Year Floor tim e 1 Year Floor tim e 4 W eeks10% RH. M oisture Level 4 M oisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag contains CAUTION Floor tim e 72 Hours Floor tim e 48 Hours Floor tim e 24 Hours 30 ˚C/60% RH. LEVEL If blank, see bar code label Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card according JEDEC-STD-033.
13 Version 1.3 | 2021-09-30 Discontinued Notes The evaluation of eye safety occurs according to the standard IEC 62471:2006 (photo biological safety of lamps and lamp systems). Within the risk grouping system of this IEC standard, the device specified in this data sheet fall into the class exempt group (exposure time 10000 s). Under real circumstances (for expo- sure time, conditions of the eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. When looking at bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irrita- tion, annoyance, visual impairment, and even accidents, depending on the situation. Subcomponents of this device contain, in addition to other substances, metal filled materials including silver. Metal filled materials can be affected by environments that contain traces of aggressive substances. There- fore, we recommend that customers minimize device exposure to aggressive substances during storage, production, and use. Devices that showed visible discoloration when tested using the described tests above did show no performance deviations within failure limits during the stated test duration. Respective failure limits are described in the IEC60810. For further application related information please visit www.osram-os.com/appnotes
14 Version 1.3 | 2021-09-30 Discontinued Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version on the OSRAM OS website. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Product and functional safety devices/applications or medical devices/applications OSRAM OS components are not developed, constructed or tested for the application as safety relevant component or for the application in medical devices. OSRAM OS products are not qualified at module and system level for such application. In case buyer – or customer supplied by buyer – considers using OSRAM OS components in product safety devices/applications or medical devices/applications, buyer and/or customer has to inform the local sales partner of OSRAM OS immediately and OSRAM OS and buyer and /or customer will analyze and coordi- nate the customer-specific request between OSRAM OS and buyer and/or customer.
15 Version 1.3 | 2021-09-30 Discontinued Glossary 1) Photocurrent: The photocurrent values are measured (by irradiating the devices with a homogenous light source and applying a voltage to the device) with a tolerance of ±11 %. 2) Typical Values: Due to the special conditions of the manufacturing processes of semiconductor devic- es, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could dif- fer from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 3) Testing temperature: TA = 25°C (unless otherwise specified) 4) Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and dimensions are specified in mm. 5) Tape and Reel: All dimensions and tolerances are specified acc. IEC 60286-3 and specified in mm.
16 Version 1.3 | 2021-09-30 Discontinued
Revision History
1.3 2021-09-30 Schematic Transportation Box Dimensions of Transportation Box Brand Discontinued
17 Version 1.3 | 2021-09-30 Discontinued Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.