Version 1.1 LP A676 Features: Besondere Merkmale:
- Package: white SMT package, colorless clear resin
- Gehäusetyp: weißes SMT Gehäuse, farbloser klarer Verguss
- Technology: InGaAlP • Technologie: InGaAlP
- Viewing angle at 50 % IV: 120° (Lambertian Emitter)
- Abstrahlwinkel bei 50 % IV: 120° (Lambertscher Strahler)
- Color: pure green (560 nm) • Farbe: pure green (560 nm)
- Corrosion Robustness: Improved corrosion robustness
- Korrosionsstabilität: Verbesserte Korrosionsstabilität Applications Anwendungen
- Optical Indicator • Optischer Indikator
- Coupling into light guides • Einkopplung in Lichtleiter
- Backlighting • Hinterleuchtung
- Automotive Interior Lighting • Automobilbeleuchtung innen
- Signal and Symbol Luminary • Signal- und Symbolleuchten
- Dashboard Backlighting • Instrumentenbeleuchtung
Version 1.1 LP A676
Ordering Information
Type: Luminous Intensity 1) page 18 Ordering Code Typ: Lichtstärke 1) Seite 18 Bestellnummer IF = 20 mA IV [mcd] LP A676-L1M2-25 11.2 ... 28 Q65110A2286 Note: The above Type Numbers represent the order groups which include only a few brightness groups (see page 5). Only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LP A676-L1M2-25 means that only one group L1, L2, M1, M2 will be shippable for any packing unit. In order to ensure availability, single brightness groups will not be orderable. In a similar manner for colors where wavelength groups are measured and binned, single wavelength groups will be shipped on any one packing unit. E. g. LP A676-L1M2-25 means that only one wavelength group 2,3,4,5 will be shippable. LP A676-L1M2-25 means that the device wil l be shipped within the specified limits as stated on page 5In order to ensure availability, single wavelength groups will not be orderable (see pa ge 5). Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LP A676-L1M2-25 bedeutet, dass in einer Verpack ungseinheit nur eine der Helligkeitsgruppen L1, L2, M1, M2 enhalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne Helligkeitsgruppe n nicht bestellt werden. Gleiches gilt für die Farben, bei denen Wellenlängengruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Wellenlängengruppe geliefert. Z. B. LP A676-L1M2-25 bedeutet, dass in einer Verpackungseinheit nur eine der Wellenlängengruppen 2,3,4,5 enthalten ist (siehe Seite 5). LP A676-L1M2-25 bedeutet, dass das Bauteil innerhalb der spezifizierten Grenzen geliefert wird. Um die Liefersicherheit zu gewährleisten, können einzelne Wellenlängengruppen nicht bestellt werden.
Version 1.1 LP A676 2013-08-30 3 Maximum Ratings Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating temperature range Betriebstemperatur Top -40 ... 100 °C Storage temperature range Lagertemperatur Tstg -40 ... 100 °C Junction temperature Sperrschichttemperatur Tj 125 °C Surge current Stoßstrom IFM 300 mA Reverse voltage 2) page 18 Sperrspannung 2) Seite 18 (TS = 25 °C) VR 12 V ESD withstand voltage ESD Festigkeit (acc. to ANSI/ESDA/JEDEC JS-001 - HBM) VESD up to 2 kV
Version 1.1 LP A676 Characteristics (TS = 25 °C; IF = 20 mA) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Wavelength at peak emission Wellenlänge d. emittierten Lichtes (typ.) λpeak 562 nm Dominant Wavelength 3) page 18 Dominantwellenlänge 3) Seite 18 (min.) (typ.) (max.) λdom λdom λdom 554 560 566.5 nm nm nm Spectral bandwidth at 50% Irel max Spektrale Bandbreite b. 50% Irel max (typ.) Δλ 22 nm Viewing angle at 50 % IV Abstrahlwinkel bei 50 % IV (typ.) 2 ϕ 120 ° Forward voltage 4) page 18 Durchlassspannung 4) Seite 18 (min.) (typ.) (max.) VF VF VF 1.80 2.00 2.40 V V V Reverse current Sperrstrom (VR = 12 V) (typ.) (max.) IR IR 0.01 μA µA Temperature coefficient of λpeak Temperaturkoeffizient von λpeak (typ.) TC λpeak 0.1 nm/K Temperature coefficient of λdom Temperaturkoeffizient von λdom (typ.) TC λdom 0.1 nm/K Temperature coefficient of VF Temperaturkoeffizient von VF (typ.) TC V -2.30 mV/K Real thermal resistance junction / ambient 5) page 18 , 6) page 18 Realer Wärmewiderstand Sperrschicht / Umgebung 5) Seite 18 , 6) Seite 18 (max.) R th JA real 530 K/W Real thermal resistance junction / solder point 6) page 18 Realer Wärmewiderstand Sperrschicht / Lötpad 6) Seite 18 (max.) R th JS real 300 K/W
Version 1.1 LP A676 2013-08-30 5 Brightness Groups Helligkeitsgruppen Dominant Wavelength Groups 3) page 18 Dominant Wellenlängengruppen 3) Seite 18 Group Luminous Intensity 1) page 18 Luminous Intensity 1) page 18 Luminous Flux 7) page 18 Gruppe Lichtstärke 1) Seite 18 Lichtstärke 1) Seite 18 Lichtstrom 7) Seite 18 (min.) Iv [mcd] (max.) Iv [mcd] (typ.) ΦV [mlm] L1 11.2 14 40 L2 14 18 50 M1 18 22.4 60 M2 22.4 28 75 Note: The standard shipping format for serial types includes either a lower family group, an upper family group or a grouping o f all individual brightness groups of only a few brightness groups. Individual brightness groups cannot be ordered. Anm.: Die Standardlieferform von Serientypen beinhaltet entweder eine untere Familiengruppe, eine obere Familiengruppe oder ein e Sammelgruppe, die aus nur wenigen Helligkeitsgruppen besteht. Einzelne Helligkeitsgruppen sind nicht bestellbar. Group pure green Gruppe (min.) λdom [nm] (max.) λdom [nm] 2 554 557 3 557 560 4 560 563 5 563 566.5 Note: No packing unit / tape ever contains more than one color group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Farbe enthalten.
Version 1.1 LP A676 Group Name on Label Gruppenbezeichnung auf Etikett Example: L1-2 Beispiel: L1-2 Brightness Helligkeit Wavelength Wellenlänge L1 2 Note: No packing unit / tape ever contains more than one group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
Version 1.1 LP A676 2013-08-30 7 Relative Spectral Emission - V( λ) = Standard eye response curve 7) page 18 Relative spektrale Emission - V( λ) = spektrale Augenempfindlichkeit 7) Seite 18 Irel = f (λ); TS = 25 °C; IF = 20 mA Radiation Characteristics 7) page 18 Abstrahlcharakteristik 7) Seite 18 Irel = f (ϕ); TS = 25 °C 400 relI 100 nm λ OHL00570 Vλ 450 500 550 600 650 700 greenpure-green 0.2 0.4 1.0 0.8 0.6 ϕ 1.0 0.8 0.6 0.4 50˚ 60˚ 70˚ 80˚ 90˚ 100˚
Version 1.1 LP A676 Forward Current 7) page 18 Durchlassstrom 7) Seite 18 IF = f (VF); TS = 25 °C Relative Luminous Intensity 7) page 18 , 8) page 18 Relative Lichtstärke 7) Seite 18 , 8) Seite 18 IV/IV(20 mA) = f(IF); TS = 25 °C Relative Luminous Intensity 7) page 18 Relative Lichtstärke 7) Seite 18 IV/IV(25)°C = f(Tj); IF = 20 mA OHL00457 1.4 IF VF mA 10-1 100 101
102 OHL03883
(20 mA) V VI I IF 100 51 0 1 10mA 2 -110 10-2 100 110 pure green green pure green green T OHL00568 V (25 ˚C)I -40 ˚C j IV 0.5 1.0 1.5 2.0 2.5 3.0 pure-green green -20 02 0 4 0 60 100
Version 1.1 LP A676 2013-08-30 9 Max. Permissible Forward Current Max. zulässiger Durchlassstrom IF = f (T) Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit I F = f(tp) D: Duty cycle, TA = 25 °C Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit I F = f(tp) D: Duty cycle, TA = 85 °C OHL01031 00 20 40 60 80 ˚C 100 T IF temp. ambient temp. solder point A ST mA AT ST OHL00316 FI 10 10-5 -4 -3 10 10 -2 10-1 100 s101 102 pt 0.05 0.5 0.2 0.1D 0.02 0.01 0.005 -210 -110 010 A D T t = P t T P IF OHL01432 FI 10 10-5 -4 -3 10 10 -2 10-1 100 s101 102 pt 0.05 0.5 0.2 0.1D 0.02 0.01 0.005 D T t = P t T P IF 10-1 10-2 A
Version 1.1 LP A676 Package Outline 9) page 18 Maßzeichnung 9) Seite 18 Approximate Weight: 67 mg Gewicht: 67 mg Mark: bevelled edge (Cathode) Markierung: abgeschrägte Ecke (Kathode) Corrosion robustness: Test conditions: 40 °C / 90 % rh / 15 ppm H2S / 336 h = Stricter than IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 days] = Regarding relevant gas (H2S) stricter than EN 60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb SO 2, 200 ppb NO2,10 ppb Cl2 / 21 days] Korrosionsfestigkeit: Test Kondition: 40°C / 90 % rh / 15 ppm H 2S / 336 h = Besser als IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 Tage] = Bezogen auf das Gas (H2S) besser als EN 60068-2-60 (method 4) [25°C / 75 % rh / 200ppb SO2, 200ppb NO2,10ppb Cl2 / 21 Tage] GPLY6880 (R1) Cathode marking Cathode Anode (2.4 (0.094)) 2.8 (0.110) 2.4 (0.094) 4.2 (0.165) 3.8 (0.150) 0.9 (0.035) 1.1 (0.043) spacing 2.54 (0.100) (1.4 (0.055)) (0.3 (0.012)) 3.4 (0.134) 3.8 (0.150) 3.8 (0.150) 4.2 (0.165) (2.9 (0.114)) AC
Version 1.1 LP A676 2013-08-30 11 Recommended Solder Pad 9) page 18 Reflow soldering Empfohlenes Lötpaddesign 9) Seite 18 Reflow-Löten 3.7 (0.146) 1.2 (0.047) 3.0 (0.118) Cu-area > 16 mm Cu-Fläche > 16 mm Paddesign for improved heat dissipation Wärmeableitung für verbesserte Padgeometrie Lötstopplack Solder resist OHLPY965
Version 1.1 LP A676 Reflow Soldering Profile Reflow-Lötprofil Preconditioning: JEDEC Level 2 acc. to JEDEC J-STD-020D.01 00 s OHA04525 100 150 200 250 300 50 100 150 200 250 300 t T St t Pt Tp240 ˚C 217 ˚C 245 ˚C 25 ˚C L Profil-Charakteristik Profile Feature Ramp-up Rate to Preheat*) 25 °C to 150 °C 2 3 K/s Time tS TSmin to TSmax tS tL tP TL TP 100 12060 10 20 30 80 100 217 2 3 245 250 3 4 Time 25 °C to TP Time within 5 °C of the specified peak temperature TP - 5 K Ramp-down Rate* TP to 100 °C All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range Ramp-up Rate to Peak*) TSmax to TP Liquidus Temperature Peak Temperature Time above Liquidus temperature Symbol Symbol Einheit Unit Pb-Free (SnAgCu) Assembly Minimum MaximumRecommendation K/s K/s s s s s 480
Version 1.1 LP A676 2013-08-30 13 Method of Taping 9) page 18 Gurtung 9) Seite 18 OHAY2273 1.5 (0.059) 4 (0.157) 2 (0.079) 3.95 (0.156) 5.5 (0.217) 1.75 (0.069) 12 (0.472) Cathode/Collector Marking
Version 1.1 LP A676 Tape and Reel Gurtverpackung 12 mm tape with 2000 pcs. on ∅ 330 mm reel Tape dimensions in mm (inch) Tape dimensions in mm (inch) Reel dimensions in mm (inch) Ree l di mens ions i n mm (i nch) W P0 P1 P2 D0 E F (0.157 ± 0.004) 4 ± 0.1 (0.157 ± 0.004) or 8 ± 0.1 (0.315 ± 0.004) 2 ± 0.05 (0.079 ± 0.002) 1.5 ± 0.1 (0.059 + 0.004) 1.75 ± 0.1 (0.069 ± 0.004) 5.5 ± 0.05 (0.217 ± 0.002) A W Nmin W1 W2max 0.079) 18.4 (0.724) W FE Direction of unreeling N A OHAY0324 Label Leader: Trailer: 13.0 Direction of unreeling ±0.25 min. 160 mm * min. 400 mm * *) Dimen sions acc. to IEC 602 86-3; EIA 481-D
Version 1.1 LP A676 2013-08-30 15 Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) Dry Packing Process and Materials Trockenverpackung und Materialien Note: Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC. Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten. OHA04563 (G) GROUP: 1234567890(1T) LOT NO: (9D) D/C: 1234 (X) PROD NO: 123456789 (6P) BATCH NO: 1234567890 LX XXXX RoHS Compliant BIN1: XX-XX-X-XXX-X ML Temp ST 260 °C R Pack: R18 DEMY 022 B_R999_1880.1642 R 9999(Q)QTY: Semiconductors OSRAM Opto XX-XX-X-X OHA00539 OSRAM Moisture-sensitive label or print Barcode label Desiccant Humidity indicator Barcode label OSRAM Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. WET Do not eat. Comparator check dot parts still adequately dry. examine units, if necessary examine units, if necessary 15% 10%bake units bake units If wet, change desiccant If wet, Humidity Indicator MIL-I-8835 If wet, M oisture Level 3 Floor tim e 168 Hours M oisture Level 6 Floor tim e 6 Hours a) Hum idity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package 2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 m onths at < 40 ˚C and < 90% relative hum idity (RH). M oisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) M ounted within b) Stored at body tem 3. Devices require baking, before m ounting, if: Bag seal date M oisture Level 1 M oisture Level 2 M oisture Level 2a4. If baking is required, b) 2a or 2b is not m et. Date and tim e opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor tim e see below If blank, see bar code label Floor tim e > 1 Year Floor tim e 1 Year Floor tim e 4 W eeks10% RH. M oisture Level 4 M oisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag contains CAUTION Floor tim e 72 Hours Floor tim e 48 Hours Floor tim e 24 Hours 30 ˚C/60% RH. LEVEL If blank, see bar code label
Version 1.1 LP A676 Transportation Packing and Materials Kartonverpackung und Materialien Dimensions of transportation box in mm (inch): Width / Breite Length / Länge Height / Höhe 349 ± 5 (13.740 ± 0.196) 349 ± 5 (13.740 ± 0.196) Notes Hinweise The evaluation of eye safety occurs according to the standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Exempt group (exposure time 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Exempt group (Expositionsdauer 10000 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen. OHA02044 PACKVAR:R077Additional TEXT P-1+Q-1 Multi TOPLED Muster OSRAM Opto Semiconductors (6P) BAT CH NO: (X) PROD NO: (9D) D/C: 11(1T) LOT NO: 210021998 123GH1234 0 245 (Q)QTY: 2000 0144 (G) GROUP:
260 C RT240
220 C RML
Bin3:Bin2: Q -1-20 Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY PACKVAR: R077Additional TEXT P-1+Q Multi T OPLED Muster OSRAM Opto Semiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 11(1T) LOT NO: 210021998 123G H1234 0 245 (Q)QTY: 2000 0144 (G) GROUP:
260 C RT
240 C R
220 C R
MLBin3:Bin2: Q-1-20 Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY OSRAM Packing Sealing label Barcode label M oisture Level 3 Floor tim e 168 Hours M oisture Level 6 Floor tim e 6 Hours a) Hum idity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package 2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 m onths at < 40 ˚C and < 90% relative hum idity (RH). M oisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) M ounted within b) Stored at body tem 3. Devices require baking, before m ounting, if: Bag seal date M oisture Level 1 M oisture Level 2 M oisture Level 2a4. If baking is required, b) 2a or 2b is not m et. Date and tim e opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor tim e see below If blank, see bar code label Floor tim e > 1 Year Floor tim e 1 Year Floor tim e 4 W eeks10% RH. M oisture Level 4 M oisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag contains CAUTION Floor tim e 72 Hours Floor tim e 48 Hours Floor tim e 24 Hours 30 ˚C/60% RH. LEVEL If blank, see bar code label Barcode label
Version 1.1 LP A676 2013-08-30 17 Disclaimer Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered. Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist.
Version 1.1 LP A676 Glossary Glossar 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of ± 8 % and an expanded uncertainty of ± 11 % (acc. to GUM with a coverage factor of k = 3). 1) Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 8 % und einer erweiterten Messunsicherheit von ± 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 2) Reverse Voltage: Driving the LED in reverse direction is suitable for short term application. 2) Sperrspannung: Die LED kann kurzzeitig in Sperrrichtung betrieben werden. 3) Wavelength: The wavelength is measured at a current pulse of typically 25 ms, with an internal reproducibility of ± 0.5 nm and an expanded uncertainty of ± 1 nm (acc. to GUM with a coverage factor of k = 3). 3) Wellenlänge: Die Wellenläge wird während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 0,5 nm und einer erweiterten Messunsicherheit von ± 1 nm gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 4) Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of ± 0.05 V and an expanded uncertainty of ± 0.1 V (acc. to GUM with a coverage factor of k = 3). 4) Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von ± 0,05 V und einer erweiterten Messunsicherheit von ± 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 5) Thermal Resistance: RthJA results from mounting on PC board FR 4 (pad size 16mm² per pad) 5) Wärmewiderstand: RthJA ergibt sich bei Montage auf PC-Board FR 4 (Padgröße 16mm² je pad) 6) Thermal Resistance: Rth max is based on statistic values (6σ). 6) Wärmewiderstand: Rth max basiert auf statistischen Werten (6σ). 7) Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 7) Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 8) Relative Brightness Curve: In the range where the line of the graph is broken, you must expect higher brightness differences between single LEDs within one packing unit. 8) Relative Helligkeitskurve: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Helligkeitsunterschieden zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden. 9) Tolerance of Measure: Dimensions are specified as follows: mm (inch). 9) Maßtoleranz: Maße werden wie folgt angegeben: mm (inch).
Version 1.1 LP A676 2013-08-30 19 Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.