TRUMPower 200 WATT SWITCHING POWER SUPPLIES ee eee ed DESCRIPTION pu200 SERIES C€ wyp) The PU200 series comprises single and multiple output models for 200 watts of continuous a output power, Auto-ranging input allows : them to operate from any line voltage through- ant te out the world without a selector strap. All J ; ut aot % auxiliary outputs are with magnetic amplifier 2 Ke >: or linear regulator to keep regulation. The poy sae units are constructed on a printed circuit ons ¥ ty board with a U-bracket for mechanical suppogt Fr ‘ and heat sinking. A cover-and-fan assembly can be added during manufacturing. n FEATURES Safety Standard Approvals: + Auto-ranging input Al UL 1950 * Overvoltage protection ® File No. E137410 * Short-circuit protection with auto-recovery Be C22.2 No. 950 * Power Fail Detect (PFD) signal File No. LR93632 ¢100% burn-in at full rated load * Optional cover-and-fan assembly EN 60950 (uv son Certificate No. R9452561 INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Input voltage: 90 to 130 VAC, or 180 to Operating temperature: 0 to +70°C

264 VAC (auto-ranging) Storage temperature: = -40C to +85°C

yaput frequency: 47 to 63 Hz Relative humidity: 5% to 95% non-condensing nput current: — 4.5A (rms) for 11SVAC ing: 2 C 2.6A (rms) for 230VAC Derating: Derate from 100% at +50 C inearly to 50% at +70 C Leakage current: 0.4mA max. @115VAC, 60Hz Cooling: 25 CFM forced air, provided 0.8mA max. @230VAC, 50Hz on "C" version, to be provided for "B" version by user OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Output voltage/current : See rating chart Switching frequency: 75KHz +/-SKHz Total output power: 200 watts maximum Efficiency : 70% minimum on all models Ripple and noise : 2% peak to peak maximum Hold-up time : 12 msec minimum at 110VAC Overvoltage protection : Provided on output #1 only; A oe 0.5% i 2 set at 112/135 % of ire Line regulation : +/-0.5% maximum at full load nominal output voltage Inrush current : 20 amps @ 115VAC, or 40 amps Overcurrent protection: All outputs protected to @ 230VAC, at 25 C cold start . short circuit conditions Withstand voltage: 3000VAC from input to output Temperature coefficient: All outputs +/-0.04%/ C 1500VAC from input to ground maximun 500VAC from output to ground Transient response : Maximum excursion of 4% . oe or better on all models: MTBF: 450.000 hours minimum at full recovering to 1% of final load at 25°C ambient, calculated value within 500us after a per MIL-HDBK-217F ; 25% step load change EMI requirements: Meets conducted limits of PED signal : TTL logic high for normal (a) FCC Level B operation and TTL logic low (b) EN 55022 Class B upon loss of input power. . “ This signal appears at least Safety requirements : Meets or exceeds: 1 ms prior to +5V output (a) UL 1950 dropping 5% below its (b) CSA C22.2 No. 950 nominal value. This signal (c) IEC 950 (EN 60950) also provides a minimum delay of 100 ms after +5V is within regulation. Ee Tumbler Technologies/TRUMPower - Palo Alto, CA + 650-494-3322 + info@trumpower.com - www. TRUMPower.com

OUTPUT VOLTAGE/CURRENT RATING CHART Maximum (1)(5)(6) Output #1 Output #2 (2) Output #3 Output #4 (3) Output PU200-10 SV 3.0A 40A 2% (N/A) (N/A) (N/A) 200W PU200-12 BV 1.2A__16.7A_ 2% (N/A) (N/A) (N/A) 200W PU200-13 15SV 1.0A 134A 2% (N/A) (N/A) (N/A) 200W PU200-16 30V OSA 6.7A 2% (N/A) (N/A) (N/A) 200W PU200-18 48V_ 05A 4.2A 2% (N/A) (N/A) (N/A) 200W PU200-23 +SV 3.0A 30A 2% +12V OA 8A 4% (N/A) (N/A) 200W PU200-24 +5V__3.0A 30A_2% +15V OA 6A 4% N/A (N/A. 200W PU200-25 = =+SV 3.0A 30A 2% +24V 0A 4A 4% (N/A) (N/A) 200W PU200-31 +SV 3.0A 30A 2% +12V OA 8A 4% -12V 0A 4A 4% (N/A) 200W PU200-32 +5V_3.0A 30A_2% +15SV OA 6A 4% -15V. 0A 4A 4% (N/A) 200W PU200-33 +5V 3.0A 30A 2% +15V 0A 6A 4% -12V 0A 4A 4% (N/A) 200W PU200-40 +5V__3.0A 30A 2% +12V OA 8A 4% -12V. 0A 4A 4% SV OA 6A 4% 200W _ PU200-41 +5V 3.04 30A 2% +15V 0A 6A 4% -1SV 0A 4A 4% 24V 0A 4A 4% 200W PU200-42 +5V__3.0A 30A_2% +12V OA 8A 4% -2V 0A 4A 4% 12Vv OA 4A 4% 200W PU200-44 +5V 3.0A 30A 2% +12V OA 8A 4% -15SV 0A 4A 4% 1sV OA 4A 4% 200W PU200-45 +5V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% 24V 0A 4A 4% 200W Notes: (1) Add suffix "B" for U-bracket format and "C” for enclosed format, e.g. PU200-45C. (2) Peak current is 12A on +12V, 9A on +15V and 6A on +24V. (3) Output #4 is floating. It can be connected externally for positive or negative output. (4) 200 watts for "C" version with a cover-and-fan assembly. 150 watts for "B" version without moving air (maximum current of output #1 & #2 derated to 70%), or 200 watts with 25 CFM forced air provided by user. (5) When the remote Sense facility is not used, +Sense must be connected to +V. and -Sense to return, on P2 connector. (6) All models may be operated at no-load. At no-load, output voltage tolerance increases to 10%. MECHANICAL SPECIFICATIONS i NOTES: 21 33341| 1, Dimensions shown in inch [mm] { | o, to —o- ~~ = - = 3. Input connector PI is Beau Inc. P/N 72-5-03C, ! output connector P2 is Beau Inc. P/N 72-5-09C. a _ 7.00 177 8) + Screws are #6-32 on 0.375 inch centers | F079 12007 Le sP] 4. Connector P3 mates with Molex housing 22-01- LG TST 1043 and Molex 40445 series crimp terminal | C3) | “MOUNTING HOLE, THREADED _ 3), jg] 5- Connector P4 mates with Molex housing 22-01- | 3.53 [89.66] | INSERT FOR #8-32 OR M4 p4 Ed i [ell 1023 and Molex 40445 series crimp terminal | PI { — PU200-14, -16, -25), or 12V/0.2A (other models). fl i i aren | nap aye 7. Weight: | — <a -—-—--— 268 1.2 Kgs (2.65 Lbs.) approx. for "B" version t CGA a _| 1.5 Kgs (3.31 Lbs.) approx. for "C" version PIN CHART cs | MoDeL Pe fr fs fo fepe ts fe PU200-10 PU200-12 : : y : | PU200-13 PU200-14 | AC | AC ac | sense | rer ) OUTPUT | OUTPUT | OUTPUT | cece | pan | COM | COM | pep PUD00.16 PU200~8 | LIVE | NEUTRAL | GROUND “ " “1 RET. | RET | PU200-23 PU200-24 | ac AC AC OUTPUT CoM | OUTPUT C. C COM. COM. THE FERRET Soo) SE [PET [ET | se [ne [om LS [| PU200-32 PU200-33 | tive | NEUTRAL | GROUND. we RET. m2 rs RET RET PU200-40 PU200-41 C rr Pt - 7 B38 O ae POO ay] ac | ac ac] oureur | com, [our | ouwur | ourrur | ourmur | py | com | com | pu200-45 Live | NEUTRAL | GRounD | — #1 RET 2 3 RETURN ” RET. SE