OPERATION & MAINTENANCE INSTRUCTIONS GC1124 ORIGINAL INSTRUCTIONS ENGINE DRIVEN SEMI TRASH 2” PUMP MODEL NO: PS50 PART NO: 7230167

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INTRODUCTION Thank you for choosing this CLARKE Pump. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. The function of this pump is to move clean /dirty water (with solids in suspension up to 15 mm in diameter). DO NOT use it to pump:

  • S e w a g e
  • Dangerous liquids - (Flammable or corrosive)
  • Salt water Before you use this pump read the manual fully. GUARANTEE This pump is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase. This guarantee is invalid if the pump has been abused, tampered with, or not used for its primary function. Faulty goods must be returned to their place of purchase, no pump can be returned to us without prior permission. This guarantee does not effect your statutory rights. INVENTORY You should find the items in the list below in the carton. Speak to your CLARKE dealer If items are missing or damaged. 1 x Petrol Powered 2" Water Pump 2 x Rubber Sealing Rings 2 x 2" BSP Inlet/outlet fittings 1 x Spark Plug Box Wrench 1 x Plastic x Inlet Strainer (in two pieces) 6 x Hose Clips

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com GENERAL SAFETY RULES 1. ALWAYS obey all safety precautions for the handling of fuel. 2. ALWAYS make sure that you are familiar with this pump, and follow all instructions in this manual. 3. ALWAYS make sure that the pump is positioned correctly to prevent it from moving during operation. 4. Keep the area adjacent to the pump clear. 5. ALWAYS connect the strainer to the suction hose to stop stones and other solids from being pulled into the pump. These can cause damage to the pump. 6. ALWAYS keep the pump dry and clear of discharge hose. 7. Only use parts supplied by the manufactu rer. Using non-standard parts can be dangerous. 8. ALWAYS use at least 300mm of flexible hose to make plumbing connections to the pump. Rigid piping can put stress on the pump, causing damage. If you use rigid piping, it must be supported to eliminate stress on the connections. 9. DO NOT refuel the engine while it is operating and let the engine cool sufficiently before refuelling. 10. DO NOT use to pump petrol (or other flammable liquids), or corrosive chemicals. The function of this pump is to pump WATER ONLY. 11. DO NOT operate this pump in an explosive atmosphere, near combustible materials, or where there is insufficient ventilation. 12. DO NOT let children use this pump. 13. DO NOT run the pump dry. ALWAYS fill the pump with water before starting. 14. DO NOT direct the discharge flow towards another person. 15. DO NOT over-tighten drain or filler plugs. Excessive force can damage the threads or the pump body. 16. DO NOT direct the water discharge towards electrical wiring or equipment. WARNING: WHEN USING PUMPS, ALWAYS FOLLOW BASIC SAFETY PRECAUTIONS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY. READ ALL INSTRUCTIONS BEFORE YOU OPERATE THIS PUMP AND SAVE THEM FOR FUTURE REFERENCE.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com GENERAL SAFETY IN THE WORKPLACE 1. ALWAYS keep work area clean & tidy. Cluttered work areas invite accidents. 2. NEVER over-reach. Keep proper footing and balance at all times. 3. ALWAYS make sure that the workplace is well lit. Make sure that that lighting is placed so that you will not be working in your own shadow. 4. Dress correctly. Loose clot hing or jewellery can get caught in moving parts. Non- slip footwear is recommended. Wear protective hair covering to contain long hair. 5. ALWAYS wear safety glasses. (Everyday glasses are not safety glasses). CARE OF PUMPS 1. The CLARKE service department can replace damaged components. 2. ALWAYS examine the pump for damage that can effect the operation of the pump. Repair any damaged parts. 3. Have your pump repaired by a qualified person. Repairs must only be carried out by qualified persons using original spare parts. Keep the instructions for future reference. SAFETY SYMBOLS The meanings of the markings and symbols on the pump are shown below Read this manual before use and keep it for future reference WARNING: Hot surfaces Wear ear protection when in operation WARNING: Adhere to safety information on label WARNING: Loud noise when in operation WARNING: Flammable substances

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ASSEMBLY INSTALL THE SUCTION HOSE 1. Fit the rubber washer into the adaptor making sure that it is seated correctly. 2. Screw the adaptor onto the pump securely. 3. Slide the hose on to the adaptor and lock in position with the jubilee clip supplied. 4. Install the strainer on to the other end of the hose using the other clip supplied.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INSTALL THE DISCHARGE HOSE 1. Fit the rubber washer into the other adaptor making sure it is seated correctly. 2. Screw the adaptor onto the pump securely. 3. Slide the hose on to the adaptor and lock in position with the jubilee clip supplied.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com BEFORE USE PUMP PLACEMENT For best pump performance, place the pump near the water level, and use hoses that are no longer than necessary. That will enable the pump to produce the greatest output with the least self-priming time. As head (pumping height) increases, pump output decreases. The length, type, and size of the suction and discharge hoses can also significantly affect pump output. Discharge head capability is always greater than suction head capability, so it is important for suction head to be the shorter part of total head

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CHECKING/FILLING THE ENGINE OIL BEFORE USE NOTE: The pump will normally be shipped without oil in the engine and will require filling before use. 1. Turn the oil filler cap anti-clockwise and remove from the oil fill tube. 2. Clean the dipstick with a clean cloth. 3. Put the dipstick into the oil fill tube and then remove it again. DO NOT screw in the oil filler cap/dipstick when doing this. 4. If the oil level is at or below the ‘L’ mark on the dipstick, add oil to the crankcase.

  • Fill until the oil touches the threads in the oil fill tube.
  • Oil capacity (See page 20).
  • We recommend that you use CLARKE SAE10W30 oil (Part No: 3050845) in this pump available from your CLARKE dealer. 5. Replace the oil filler cap. WARNING: TO DO THIS CHECK, PUT THE PUMP ON LEVEL GROUND WITH THE ENGINE SWITCHED OFF. WARNING: TAKE CARE NOT TO TOUCH ANY HOT PARTS OF THE PUMP WHEN CHECKING THE OIL LEVEL.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ADD FUEL RECOMMENDED FUEL Only use unleaded petrol. 1. Remove the fuel tank cap.

  • In the fuel tank is a fuel filter which collects contaminants as you refuel. 2. Carefully add fuel to the fuel tank.
  • Make sure that the fuel filter is free of contamination.
  • The max capacity of fuel is 3.6L. 3. Replace the fuel tank cap. WARNING: REFUEL IN A VENTILATED AREA, AWAY FROM SOURCES OF IGNITION. WARNING: IF THE ENGINE IS HOT, LET IT COOL BEFORE REFUELING. WARNING: KEEP FUEL OUT OF THE REACH OF CHILDREN.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com OPERATION PRIME THE PUMP The pump must be primed before use. 1. Before starting the engine, remove the filler cap from the pump chamber. 2. Fill the pump chamber and inlet hose with water. NOTE: A foot valve (not supplied) connected to the lower end of the inlet hose between the hose and the strainer will help to maintain priming, 3. Replace the filler cap and tighten it securely. WARNING: WHEN YOU OPERATE THE PUMP, THE EXHAUST MUFFLER WILL BE VERY HOT. WARNING: DO NOT OPERATE THE ENGINE IN A CLOSED SPACE, MAKE SURE THAT THERE IS SUFFICIENT AIRFLOW AROUND THE PUMP DUE TO HARMFUL EMMISSIONS/ FUMES FROM THE ENGINE. WARNING: OPERATING THE PUMP DRY WILL DESTROY THE PUMP SEAL. IF THE PUMP IS OPERATED DRY, STOP THE ENGINE IMMEDIATELY AND LET THE PUMP COOL BEFORE PRIMING

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com STARTING THE ENGINE 1. Set the fuel valve to the ON position. 2. To start a cold engine, move the choke lever to the ‘ON’ position.

  • To restart a warm engine, move the choke lever to the ‘OFF’ position. 3. Move the throttle lever away from Slow about 1/3 of the way. 4. Set the engine switch to ‘ON’.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 5. Pull the starting handle lightly until you start to feel resistance. Then pull up and away suddenly to start the engine. NOTE: You might need to do this more than once. 6. Once the engine has warmed up from a cold start, move the choke lever to the ‘OFF’ position. SETTING THE ENGINE SPEED After starting the engine, move the throttle lever to the FAST position for self-priming and check pump output. Pump output is controlled by adjusting engine speed.

  • Moving the throttle lever in the FAST direction will increase pump output.
  • Moving the throttle lever in the SLOW direction will decrease pump output. WARNING: WHEN THE PUMP HAS STARTED, RELEASE THE STARTING HANDLE SLOWLY TO PREVENT INJURY/DAMAGE AS IT RETURNS.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SHUTTING DOWN THE PUMP To stop the pump in an emergency, set the engine switch to ‘OFF’. 1. Use the throttle lever to decrease engine speed to minimum. 2. Set the engine switch to “OFF”. 3. Turn the fuel valve to “OFF”. AFTER USE 1. Remove the pump drain plug and drain the pump chamber. 2. Remove the filler cap and flush the pump chamber with clean, fresh water.

  • Allow the water to drain from the pump chamber. 3. Reinstall the filler cap and drain plug.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com MAINTENANCE CLEARING BLOCKAGES 1. Remove the hoses and adaptors from the pump. 2. Remove the four bolts shown in the picture. 3. Remove the front cover. 4. Clear debris and clean the inner parts using clean water. 5. Replace the front cover and secure using the four bolts removed in step CHANGING THE ENGINE OIL Change the oil in the engine after the first 20 hours use and thereafter every 6 months or 100 running hours. 1. Unscrew and remove the oil filler cap/dipstick. CAUTION: PROLONGED EXPOSURE TO USED ENGINE OIL IS DANGEROUS, ALWAYS WASH YOUR HANDS THOROUGHLY AFTER HANDLING USED ENGINE OIL.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 2. Put a oil collection tray below the drain plug. 3. Unscrew the drain plug and let the used engine oil drain from the crankcase into the oil collection tray. NOTE: Drain the engine oil when the engine is warm, this will make sure that the oil flows out faster. 4. Replace the drain plug. 5. Fill the crankcase with engine oil.

  • Fill until the oil touches the threads in the oil fill tube.
  • Oil capacity (0.6 L).
  • We recommend that you use CLARKE SA E10W30 oil (Part No: 3050845) in this pump available from your CLARKE dealer. 6. Replace the oil f iller cap/dipstick. ENVIRONMENTAL PROTECTION One of the most damaging sources of pollution is oil, DO NOT throw away or pour it down drains. Put it in a leak proof container and take it to your local waste disposal site. CHANGING THE SPARK PLUG Replace the spark plug after the first month or every 50 hours of use. 1. Remove the spark plug cap from the spark plug.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 2. Use the spark plug spanner supplied to remove the spark plug. 3. Remove any carbon that has collected around the electrode. 4. Check the spark plug gap (a), it should be between 0.7 and 0.8 mm, adjust if necessary. 5. Check the overall condition of the spark plug for erosion or pitting and replace if necessary. 6. Reinstall the spark plug and replace the spark plug cap. CHANGING THE AIR FILTER Clean the air filter after 50 hours of operation (or more often in unusually dusty conditions) as follows. 1. Unscrew the wingnut and lift off the air filter cover. 2. Remove the air filter element. 3. Clean the air filt er or replace if necessary.

  • If the filter is dirty, wash the filter in a solution of warm water and mild detergent and rinse thoroughly. Leave the filter to dry completely,

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 4. Once it is dry, Dip in clean engine oil and squeeze out excess oil.

  • DO NOT operate the pump without the air cleaner installed as this will cause premature wear to the engine. STORAGE 1. Always keep the pump in a dust and da mp free environment away from children. MAINTENANCE RECORD OIL CHANGE: SPARK PLUG CHANGE: AIR FILTER CHANGE: MISCELLANEOUS:

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com TROUBLESHOOTING PROBLEM CAUSE SOLUTION The engine does not start. No fuel in tank. Add fuel. Fuel valve is set to OFF S et the fuel valve to ON. Engine switch is in the OFF position. Set engine switch to the ON position. Lack of spark at the spark plug. Make sure that the spark plug cover is fitted on to the plug. With the engine switch in the ON position, hold the spark plug electrode against the engine and pull the starter cord. If a spark is present but engine will not start, consult your CLARKE dealer. The engine stops and will not restart. No fuel in tank. Add fuel to the tank. The pump fails to prime. Priming chamber not filled correctly. Fill priming chamber leaving no air gap. Air leaking due to damaged hose, broken hose clamps, split/ill- fitting gasket. Repair as necessary. Blocked inlet hose. Clean strainer and make sure that it is not submerged in mud or sediment. Make sure that there are no kinks in the delivery hose. Engine speed too low. In crease engine speed. Damaged impeller. Disassemble the pump and replace the impeller. Air leaking through damaged seal. Replace seal.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com If you cannot correct the fault, speak to your local dealer or the CLARKE International service department. ENVIRONMENTAL PROTECTION At the end of its working life, DO NOT discard this pump or its components with general household waste. Packaging must be taken to a recycling centre and discarded appropriately. One of the most dangerous sources of pollution is oil. DO NOT discard used oil with domestic refuse or flush down a sink or drain. Collect the oil in a leak-proof container and take it to your local waste disposal site. Low output from pump. The engine speed is too low. Increase the engine speed. Pickup or delivery hose obstructed. Clear obstruction and make sure that there are no kinks in hose. Suction lift too high. Set the pump nearer to the water level. Congested material inside pump. Disassemble the pump and clean out. Damaged impeller. Disassemble the pump and replace the impeller. PROBLEM CAUSE SOLUTION

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SPECIFICATION Item Specification Model No PS50 Pump Dimensions (L X W X H) 505 x 405 x 440 mm Pump Weight (Kgs) 22 kg Water Classification Semi-dirty water Max Solids In Suspension 15 mm Inlet/outlet Size 2” BSP Maximum Flow 450l/min Rated Head 28 m Suction Head 7-8 m Max Pressure 2.8 bar Engine power 5.4HP Fuel Tank Capacity (Petrol) 3.6 L Fuel consumption 1.8L/hr Lubrication Oil Capacity/grade 0.6 L (SAE 15W40) Sound Pressure Level 87.95 dB LpA Sound Power Level 101.1 dB LWA Guaranteed Sound Power Level 104 dB LWA Uncertainty Factor (K) 2.5 dB

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com COMPONENT PARTS A full set of engine parts list and diagrams are available from the CLARKE International service department. WATER PUMP ASSEMBLY No Description No Description

1 Hose clip 16 Pump body

2 Filter cover 17 Case sealing

3 Filter body 18 Casing

6 Washer 21 Impeller

7 Adaptor ring nut 22 n/a

8 Hose seal connector 23 Pump joint gasket

9 2” pipe connector 24 Seal

10 Water inlet 25 Porcelain seal

11 Water inlet gasket 26 Seal assembly

12 Plug 27 Pump end plate

13 Washer for plug 28 Washer

14 Water outlet elbow 29 Bolt

15 Outlet gasket 30 Pump assembly complete

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATIONS OF CONFORMITY -UK