6 CAT-PM--E-04 ASM GmbH
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com Order code PMIS3 Model name Magnetic period 20 = 2 mm / 50 = 5 mm Resolution (in µm) with times 4 counting mode Mag. period 2 mm: 5 / 10 / 20 / 50 Mag. period 5 mm: 10 / 25 / 50 / 125 Max. pulse frequency (in kHz, standard 50 kHz) 50 / 20 / 10 Output HTL = HTL output with excitation 24 VDC, output 24 V TTL = TTL output with excitation 5 VDC, output TTL/RS422 TTL24V = TTL output with excitation 24 VDC, output TTL/10 mA Reference pulse/ end position signal/ status signal Z0 = A/B w/o reference pulse / Z1 = A/B with reference pulse Z Z2 = A/B with end position signal / *Z3 = A/B with reference pulse and status signal (Option Z3 only for non-diferential output, single ended) Cable length (in m, standard 2 m) Connection S = Cable output, open end P = Connector D-sub, 9 pin, at the cable end Very compact sensor for industrial applications Sensor head PMIS3
- Non-contact, no wear
- High velocity
- Robust shielded metal enclosure
- Protection class IP67
- Incremental encoder output A/B/Z
- Signal processing as usual with encoders
- Reference pulse and end position signal
- Indicator for velocity/position errors A POSIMAG measuring system consists of the sensor head PMIS3 and the magnetic scale PMIB3 with the same magnetic period. Specifi cations Output Incremental encoder output A/B with differential push-pull output, TTL/RS422 or HTL compatible Excitation voltage 10 ... 30 VDC or 5 VDC ±5 % Excitation current 50 mA to 300 mA, depending on pulse frequency, cable length and load Magnetic period of the sensor 2 mm 5 mm Side tracking tolerance of the sensor ±1 mm ±1 mm Linearity (sensor with mag. scale PMIB3) 15 µm ± 40 µm/m 30 µm ± 40 µm/m Repeatability ± 1 digit ± 1 digit Resolution with ext. times 4 counting mode [µm] 5 1 02 05 01 02 55 0 125 Max. velocity with fp=50 kHz [m/s] (20 kHz: x 0.4; 10 kHz: x 0.2) 0.8 1.6 3.2 8 1.6 4 8 20 Order example: PMIS3 - 50 - 25 - 50KHZ - HTL - Z1 - 2M - S PMIS3 POSIMAG® Magnetic Scale Position Sensor
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com Specifi cations (continued) Max. pulse frequency fp 50 kHz, 20 kHz, 10 kHz (standard 50 kHz) Outputs A, A, B, B, reference pulse Z, Z, end position signal E, E, status signal ERR Material of enclosure Zinc die casting Electrical connection Cable 8 wire, Ø 5 mm, open cable end, 9 pin D-sub connector as option Weight (w/o cable and connector) 30 ±5 g Protection class (EN 60529) IP67 Environmental EMC DIN EN 61326 Temperature -20 ...+85°C A POSIMAG measuring system consists of the sensor head PMIS3 and the magnetic scale PMIB3 with the same magnetic period. The subsequent counting device must be able to process the specifi ed maximum pulse frequency of the sensor. Output signals Saturation voltage UH, UL = 0,2 V I out = ±10 mA (UH = UB - U out) UH, UL = 0,4 V I out = ±30 mA Clast < 10 nF Short circuit current ISL, ISH < 800 mA (UH, UL = 0 V) ISL, ISH < 90 mA (UH, UL = 1,5 V) Rise time t r, tf < 200 ns with cable length 1 m, 10 % … 90 % Pulse frequency in dependence on the cable length Load/cable length Load/pulse frequency fp HTL single ended UB = 24 V TTL/RS422 differential UB = 5 V * TTL/24 V UB = 24 V Max. output current 50 mA 50 mA 10 mA Rlast min. 500 Ω 100 Ω 500 Ω Clast max. 10 nF 10 nF 1 nF 200 m 15 kHz — — 100 m 25 kHz 100 kHz — 50 m 50 kHz 200 kHz 50 kHz 10 m 100 kHz 300 kHz 100 kHz * = note the voltage loss of the connector; excitation voltage 5 V ± 5% of the sensor must be guaran teed Outline drawing Active measurement range Status signal (LED) Dimensions informative only. For guaranteed dimensions consult factory. Reference mark PMIS3 POSIMAG® Magnetic Scale Position Sensor Position tolerance of the active measurement range: dx = ±1 mm
8 CAT-PM--E-04 ASM GmbH
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com Output signals Option Z1 (Reference pulse) Option Z2 (End position signal) ±1 mm, sw. position independent from A,B End position mark Signal wiring / connection Signal name Open cable end Cable colour Conn. D-sub, 9 pin pin no.Option Z0 Z1 Z2 Z3* Excitation + white 1 Excitation GND (0V) brown 5 B B B B green 2 A A A A yellow 3 B B B ERR grey 7 A A A − pink 6 − Z E Z blue 4 − Z E − red 8 Shield black 9 Z = reference pulse E = end position signal ERR = status signal, periodical approx. 16 Hz, for side tracking and velocity errors * = status signal ERR available only with HTL (single ended) output Cable output dimensions Connector D-sub (Pin) View to connector pins PMIS3 POSIMAG® Magnetic Scale Position Sensor
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com Specifi cations Solid measure Plastic bonded fl exible permanent magnet Base material Spring steel CK 85 Masking tape Stainless steel (non magnetic) Width 10 mm +0.1 mm / -0.2 mm Thickness (with masking tape) 1.7 mm ±0.1 mm Magnetic period 2 mm 5 mm Linearity at 25°C up to 30 m up to 50 m ±40 µm/m ±80 µm/m ±40 µm/m ±80 µm/m Reference mark (reference pulse) max. every 4 mm max. every 10 mm Measurement range must be divisible by 4 must be divisible by 10 Linear thermal expansion coeffi cient 11 x 10 -6 / K Operating temperature -10 ...+70°C An unmagnetic masking tape made of stainless steel is available (accessories). The magnetic scale is fl exible and can be glued to the surface of a cylinder with a minimum radius of 100 mm and used for angular measurements. Order code PMIB3 Model name Magnetic period 20 = 2 mm / 50 = 5 mm Mounting of the magnetic scale N = adhesive taping Measurement range (total length = range + X mm, refer to the table on page 12) Measurement ranges must be divisible by 4 (resp. by 10) Reference marks/end position marks (optional) R1 = reference mark on the left / R2 = on the right E1 = end position mark on the left / E2 = on the right Additional reference marks every 4 mm (period 2 mm) resp. 10 mm (period 5 mm) from the left Options FP = magnetic scale in fl at profi le HP = magnetic scale in high profi le AB = Masking tape (only with FP or HP) g( g g p g ) Order example: PMIB3 - 50 - N - 1500 - R1 Magnetic scale PMIB3 for Position Sensor PMIS3
- Easy splicing
- Resistant to moisture and many fl uids
- Extensive ruggedness against dust etc. The magnetic material is magnetised in defined and even dis- tances and works as a solid measure. Reference marks can be user defined in 4 mm resp. 10 mm steps. The magne- tic scale retains its firmness by means of a spring steel base (standard steel strip CK 85). PMIB3 POSIMAG® Magnetic Scale
10 CAT-PM--E-04 ASM GmbH
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com Specifi cations Solid measure Plastic bounded fl exible permanent magnet Base material Stainless steel CrNi 17 7 / PE Masking tape Stainless steel (non magnetic) Width 10 mm +0.1 mm / -0.2 mm Thickness (with masking tape) 1.7 mm ±0.1 mm Magnetic period 2 mm 5 mm Linearity at 25°C up to 30 m up to 50 m ±40 µm/m ±80 µm/m ±40 µm/m ±80 µm/m Reference mark (zero pulse) max. every 4 mm max. every 10 mm Measurement range must be divisible by 4 must be divisible by 10 Linear thermal expansion coeffi cient 11 x 10 -6 / K Operation temperature -10 ...+70°C An unmagnetic masking tape made of stainless steel is available (accessories). The magnetic scale is fl exible and can be glued to the surface of a cylinder with a minimum radius of 100 mm and used for angular measurements. Order example: PMIB3-ST - 50 - N - 1500 - R1 Magnetic scale PMIB3-ST for Position Sensor PMIS3
- Easy splicing
- Resistant to moisture and many fl uids
- Extensive ruggedness against dust, chipping etc.
- Magnetic scale with stainless steel base The magnetic material is magnetised in defined and even dis- tances and works as a solid measure. Reference marks can be user defined in 4 mm resp. 10 mm steps. The magne- tic scale retains its firmness by means of a spring steel base (stainless steel strip CrNi 17 7). Order code PMIB3-ST Model name Magnetic period 20 = 2 mm / 50 = 5 mm Mounting of the magnetic scale N = adhesive taping Measurement range (total length = range + X mm, refer to the table on page 12) Measurement ranges must be divisible by 4 (resp. by 10) Reference marks/end position marks (optional) R1 = reference mark on the left / R2 = on the right E1 = end position mark on the left / E2 = on the right Additional reference marks every 4 mm (period 2 mm) resp. 10 mm (period 5 mm) from the left Options FP = magnetic scale in fl at profi le HP = magnetic scale in high profi le AB = masking tape (only with FP or HP) PMIB3-ST POSIMAG® Magnetic Scale
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com PMIB3-HT POSIMAG® Magnetic Scale Magnetic scale PMIB3-HT for Position Sensor PMIS3
- Easy splicing
- Resistant to moisture and many fl uids
- Extensive ruggedness against dust etc.
- High temperature durability
- Magnetic scale with stainless steel base The magnetic material is magnetised in defined and even dis- tances and works as a solid measure. Reference marks can be user defined in 4 mm resp. 10 mm steps. The magne- tic scale retains its firmness by means of a spring steel base (stainless steel strip CrNi 17 7). Specifi cations Solid measure Plastic bonded fl exible permanent magnet Base material Stainless steel CrNi 17 7 / elastomer Masking tape Stainless steel (non magnetic) Width 10 mm +0.1 mm / -0.2 mm Thickness (with masking tape) 1.7 mm ±0.1 mm Magnetic period 2 mm 5 mm Linearity at 25°C up to 30 m up to 50 m ±40 µm/m ±80 µm/m ±40 µm/m ±80 µm/m Reference mark (reference pulse) max. every 4 mm max. every 10 mm Measurement range must be divisible by 4 must be divisible by Linear thermal expansion coeffi cient 11 x 10 -6 / K Operating temperature -20 ...+120°C An unmagnetic masking tape made of stainless steel is available (accessories). The magnetic scale is fl exible and can be glued to the surface of a cylinder with a minimum radius of 100 mm and used for angular measurements Order code PMIB3-HT Model name Magnetic period 20 = 2 mm / 50 = 5 mm Mounting of the magnetic scale N = adhesive taping Measurement range (total length = range + X mm, refer to the table on page 12) Measurement ranges must be divisible by 4 (resp. by 10) Reference marks/end position marks (optional) R1 = reference mark on the left / R2 = on the right E1 = end position mark on the left / E2 = on the right Additional reference marks every 4 mm (period 2 mm) resp. 10 mm (period 5 mm) from the left Options FP = magnetic scale in fl at profi le HP = magnetic scale in high profi le AB = masking tape (only with FP + HP) PMIB3-HT Order example: PMIB3-HT - 50 - N - 1500 - R1
12 CAT-PM--E-04 ASM GmbH
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com PMIS3/ PMIB3/-HT/-ST POSIMAG® Magnetic Scale Position of the standard reference marks ERR Z A A Dimensions reference Magnetic period Switching position A Total length B 2 mm 20.0 ±1 mm measurement range + 40 mm 5 mm 2 mm with high profi le 60.0 ±1 mm measurement range + 120 mm 5 mm with high profi le Additional reference marks every 4 mm (period 2 mm) resp. 10 mm (period 5 mm) from the left h. s. Position of the end position marks Dimensions end positions Magnetic period Switching position A Total length B 2 mm 21.0 ±1 mm measurement range + 50 mm 5 mm 22.5 ±1 mm measurement range + 50 mm 2 mm with high profi le 61.0 ±1 mm measurement range + 130 mm 5 mm with high profi le 62.5 ±1 mm measurement range + 130 mm E A A B B
PMAB 10MM— — ASM GmbH CAT-PM-E-04 13 Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com PMIS3/ PMIB3/-HT/-ST POSIMAG® Magnetoresistive Position Sensor Accesories Masking tape PMAB: Masking tape made of stainless steel for POSIMAG magnetic scale PMIB3, width 10 mm, thickness 0.2 mm Order code: Length in mm Outline drawing fl at profi le PMFP Outline drawing high profi le PMHP Mounting set PMFP-BFS1 Mounting set PMHP-BFS1 Slider for high profi le PMGW3 Mounting element PMFP Magnetic scale (w/o masking tape) Mounting element PMFP Mounting element P Magnetic scale (w/o masking tape) Mounting element P Dimensions informative only. For guaranteed dimensions consult factory.
14 CAT-PM--E-04 ASM GmbH
Tel.: 08123/986-0 Fax: 08123/986-500 www.asm-sensor.com PMIB3/-HT/-ST POSIMAG® Magnetic Scales – overview Magnetic Scales – Technical Information Types of magnetic scales / Application recommendation Type Standard scale PMIB3 Stainless steel scale PMIB3-ST Stainless steel elastomer scale PMIB3-HT base strip CK 85 stainless steel CrNi 17 7 stainless steel CrNi 17 7 stainless steel magnetic scale PE magnetic scale PE magnetic scale Elastomer magnetic scale environmental conditions normal diffi cult very diffi cult corrosion resistance normal high high temperature resistance normal normal high media resistance normal normal high Chemical durability – PE magnetic scales (PMIB3, PMIB3-ST) no / little infl uence weak / middle infl uence strong infl uence some mineral oils vegetable oils methyl / isopropanol weak organic acids formaldehyde anhydrous ammonia acetylene benzin kerosene steam, vapour acetic acid 20% / 30% sea water olein acid benzene nitrobenzene paint solvents turpentine nitric acid 70% hydrochloric acid 37% toluene xylene tetrachloromethane trichloroethylene Chemical durability – Elastomer magnetic scales (PMIB3-HT) no / little infl uence weak / middle infl uence strong infl uence motor oils gear oils ATF (automatic transmission fl uid) hydraulic fl uid kerosene antifreeze agent purifying agent turpentine water sea water/salt water JP-4 fuel (Jet fuel) gasoline/petrol heptane alcohol aromatic hydrocarbon (benzene, toluene, xylene) ketone anorganic acids (HCl, H 2SO4)