Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Photo Voltaic IPM H-Bridge + 1 Chopper
50 Amperes/600 Volts
Description: Powerex Intellimod™ 5th genera- tion PV-IPMs are isolated base modules designed for power switching applications operating at frequencies to 30kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free-wheel diode power devices. Features: £ Complete Output Power Circuit £ Gate Drive Circuit £ Protection Logic – Short Circuit – Over Temperature Using On-chip Temperature Sensing – Under Voltage £ Low Loss Using 5th Generation IGBT Chip Applications: £ PV Inverters £ PV UPS £ PV Power Supplies Ordering Information: Example: Select the complete part number from the table below -i.e. PM50B5LA060 (Package A) is a 600V, 50 Ampere PV-IPM. Type Current Rating V CES Amperes Volts (x 10) PM 50 60 Dimensions Inches Millimeters A 4.72 120.0 B 2.17 55.0 C 0.63 16.0 D 4.17 106.0 E 0.28 7.0 F 0.78 19.75 G 2.62 66.5 H 0.13 3.25 J 0.63 16.0 K 0.08 2.0 L 0.10 2.5 M 2.81 71.5 N 0.20 5.0 P 0.43 11.0 Q 0.42 10.75 R 0.87 22.0 Dimensions Inches Millimeters S 0.46 11.75 T 0.59 15.0 U 0.91 23.0 V 0.57 14.5 W 1.26 32.0 X 1.22 31.0 Y 0.69 17.5 Z 1.14 29.0 AA 0.51 13.0 AB M5 Metric M5 AC 0.22 Dia. Dia. 5.5 AD 0.28 7.0 AE 0.08 2.0 AF 0.02 Sq. Sq. 0.5 AG 0.10 Dia. Dia. 2.5 Outline Drawing and Circuit Diagram 19 FO 17 VN
14 VN1
8 VVP1
2 UFO
6 VFO
5 VVPC
1 VUPC
4 VUP1
13 VNC
Q V Y Y W P A DE GF L H J J M J K K K K R U U U T S N B AA C Z X AB (6 PLACES) AC (2 PLACES) AE AF AG (2 PLACES) N P B U V W 1 5 9 19 VCC SI GND GND OT FO IN VCC SI GND GND OT FO IN VCC SI GND GND OUT FO IN PU NC VWNNC VCC SI GND GND OUT OT OT OUT OUT OT OUT FO IN VCC SI GND GND FO IN UNFO VNC WN VN1 VN NCNCNCNC VVPC VP VFO VVP1 VUPC UP UFO VUP1 OT OUT Package A
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Description: Powerex Intellimod™ 5th genera- tion PV-IPMs are isolated base modules designed for power switching applications operating at frequencies to 30kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free-wheel diode power devices. Features: £ Complete Output Power Circuit £ Gate Drive Circuit £ Protection Logic – Short Circuit – Over Temperature Using On-chip Temperature Sensing – Under Voltage £ Low Loss Using 5th Generation IGBT Chip Applications: £ PV Inverters £ PV UPS £ PV Power Supplies Ordering Information: Example: Select the complete part number from the table below -i.e. PM50B5LB060 (Package B) is a 600V, 50 Ampere PV-IPM. Type Current Rating V CES Amperes Volts (x 10) PM 50 60 Outline Drawing and Circuit Diagram Dimensions Inches Millimeters A 4.72 120.0 B 2.17 55.0 C 0.63 16.0 D 4.17 106.0 E 0.28 7.0 F 0.78 19.75 G 2.62 66.5 H 0.13 3.25 J 0.63 16.0 K 0.08 2.0 L 0.10 2.5 M 2.81 71.5 N 0.20 5.0 P 0.31 7.75 Q 3.87 98.25 R 0.87 22.0 S 0.10 2.5 T 0.77 19.5 U 0.91 23.0 Dimensions Inches Millimeters V 0.16 4.0 W 1.01 25.75 X 2.00 50.75 Y 0.69 17.5 Z 0.30 7.5 AA 0.98 25.0 AB 0.10 Dia. Dia. 2.5 AC 0.22 Dia. Dia. 5.5 AD 0.67 17.0 AE 0.10 Dia. Dia. 2.5 AF 0.33 8.5 AG 0.08 2.0 AH 0.41 10.5 AJ 1.08 27.5 AK 0.04 1.0 AL 0.02 Sq. Sq. 0.5 AM 0.06 1.5 AN 0.04 1.0 19 FO 17 VN A GF L M H J J J KK K K V AB (4 PLACES) V N W X B V V V V V V V V S T UU U R P Q AC (2 PLACES) AJ AHAF AG AL AN AK CAD AE (2 PLACES) AM V V Y Y Z AA N P 1 5 9 13 1 9 WVUB VCC SI GND GND OT FO IN VCC SI GND GND OT FO IN VCC SI GND GND OUT FO IN PU NC VWNNC VCC SI GND GND OUT OT OT OUT OUT OT OUT FO IN VCC SI GND GND FO IN UNFO VNC WN VN1 VN NCNCNCNC VVPC VP VFO VVP1 VUPC UP UFO VUP1 OT OUT Package B
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Absolute Maximum Ratings, Tj = 25°C unless otherwise specified Characteristics Symbol PM50B5LA060 / PM50B5LB060 Units Power Device Junction Temperature Tj -20 to 150 °C Storage Temperature Tstg -40 to 125 °C Module Case Operating Temperature (Note 1) TC -20 to 100 °C Mounting Torque, M5 Mounting Screws — 31 in-lb Mounting Torque, M5 Main Terminal Screws (Package A only) — 31 in-lb Package A Module Weight (Typical) — 380 Grams Package B Module Weight (Typical) — 340 Grams Supply Voltage, Surge (Applied between P-N) VCC(surge) 550 Volts Operation of Short Circuit Protections VCC(prot.) 400 Volts (Applied between P-N, VD = 13.5 ~ 16.5V, Inverter Part, Tj = 125°C Start) Isolation Voltage, AC 1 minute, 60Hz Sinusoidal VISO 2500 Volts IGBT Inverter Part Collector-Emitter Voltage (VD = 15V, VCIN = 15V) VCES 600 Volts Collector Current (TC = 25°C) ±IC 50 Amperes Peak Collector Current (TC = 25°C) ±ICP 100 Amperes Collector Dissipation (TC = 25°C) (Note 1) PC 131 Watts Converter Part Collector-Emitter Voltage (VD = 15V, VCIN = 15V) VCES 600 Volts Collector Current (TC = 25°C) ±IC 50 Amperes Peak Collector Current (TC = 25°C) ±ICP 100 Amperes Collector Dissipation (TC = 25°C) (Note 1) PC 131 Watts Diode Rated DC Reverse Voltage (TC = 25°C) VR(DC) 600 Volts Diode Forward Current IF 50 Amperes Control Part Supply Voltage (Applied between VUP1-VUPC, VVP1-VVPC, VN1-VNC) VD 20 Volts Input Voltage (Applied between UP-VUPC, VP-VVPC, UN- VN- WN-Br-VNC) VCIN 20 Volts Fault Output Supply Voltage VFO 20 Volts (Applied between UFO-VUPC, VFO-VVPC, FO-VNC) Fault Output Supply Current (Sink Current at UFO, VFO, FO Terminals) IFO 20 mA
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units IGBT Inverter Part Collector-Emitter Saturation Voltage V CE(sat) V D = 15V, VCIN = 0V, IC = 50A, — 1.5 — Volts Pulsed, Tj = 25°C VD = 15V, VCIN = 0V, IC = 50A, — 1.55 — Volts Pulsed, Tj = 125°C Diode Forward Voltage VEC -IC = 50A, VCIN = 15V, VD = 15V — 2.2 3.3 Volts Inductive Load Switching Times ton 0.3 0.7 1.4 µs trr VD = 15V, VCIN = 0 ↔ 15V — 0.1 0.2 µs tC(on) VCC = 300V, Tj = 125°C — 0.2 0.4 µs toff Inductive Load (Per 1 Arm) — 0.9 1.8 µs tC(off) — 0.2 0.4 µs Collector-Emitter Cutoff Current ICES V CE = VCES, VCIN = 15V, Tj = 25°C — — 1.0 mA V CE = VCES, VCIN = 15V, Tj = 125°C — — 10 mA Converter Part Collector-Emitter Saturation Voltage V CE(sat) V D = 15V, VCIN = 0V, IC = 50A, — 1.5 — Volts Pulsed, Tj = 25°C VD = 15V, VCIN = 0V, IC = 50A, — 1.55 — Volts Pulsed, Tj = 125°C Diode Forward Voltage VEC -IC = 50A, VCIN = 15V, VD = 15V — 2.2 3.3 Volts Diode Forward Voltage VFM IF = 50A — 1.7 2.7 Volts Collector-Emitter Cutoff Current ICES V CE = VCES, VCIN = 15V, Tj = 25°C — — 1.0 mA V CE = VCES, VCIN = 15V, Tj = 125°C — — 10 mA Note 1: TC (under the chip) Measurement Point Package A Y BOTTOM VIEW X Y X BOTTOM VIEW Package B
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units Control Part Control Supply Voltage VD Applied between 13.5 15.0 16.5 Volts VUP1-VUPC, VVP1-VVPC, VN1- VN Circuit Current ID VD = 15V, VCIN = 15V, VN1-VNC — 20 30 mA VD = 15V, VCIN = 15V, VXP1-VXPC — 5 10 mA Input ON Threshold Voltage Vth(on) Applied between UP-VUPC, 1.2 1.5 1.8 Volts Input OFF Threshold Voltage Vth(off) V P-VVPC, UN- VN- WN-Br-VNC 1.7 2.0 2.3 Volts Short Circuit Trip Level SC Inverter Part 100 — — Amperes (-20°C ≤ Tj ≤ 125°C, VD = 15V, Inductive Load per 1 Arm) Brake Part 100 — — Amperes Short Circuit Current Delay Time toff(SC) VD = 15V — 10 — µs Over Temperature Protection* OT Trip Level 135 145 — °C (VD = 15V) OTr Reset Level — 125 — °C Supply Circuit Under-voltage Protection UV Trip Level 11.5 12.0 12.5 Volts (Tj ≤ 125°C) UVr Reset Level 12.0 12.5 13.0 Volts Fault Output Current* IFO(H) VD = 15V, VFO = 15V — — 0.01 mA IFO(L) VD = 15V, VFO = 15V — 10 15 mA Fault Output Pulse Width* tFO VD = 15V 1.0 1.8 — ms *Fault output is given only when the internal SC, OT and UV protections schemes of either upper or lower devide operate to protect it. Fault output of SC protection given pulse. Fault output of OT, UV protection given pulse while over trip level. Thermal Characteristics, Tj = 25°C unless otherwise specified Characteristic Symbol Condition Min. Typ. Max. Units Junction to Case Thermal Resistance R th(j-c)Q Inverter IGBT (Per 1 Element) (Note 1) — — 0.95 °C/Watt Rth(j-c)D Inverter FWDi (Per 1 Element) (Note 1) — — 1.61 °C/Watt Rth(j-c)Q Converter IGBT (Per 1 Element) (Note 1) — — 0.95 °C/Watt Rth(j-c)D Converter FWDi Upper Arm — — 0.95 °C/Watt (Per 1 Element) (Note 1) Rth(j-c)D Converter FWDi Lower Arm — — 1.61 °C/Watt (Per 1 Element) (Note 1) Contact Thermal Resistance Rth(c-f) Case to Fin (Per 1 Element), — — 0.038 °C/Watt Thermal Grease Applied Recommended Conditions for Use Characteristic Symbol Condition Value Units Supply Voltage VCC Applied across P-N Terminals ≤400 Volts Control Supply Voltage VD Applied between VUP1-VUPC, 15.0 ± 1.5 Volts VVP1-VVPC, VN1-VNC Input ON Voltage VCIN(on) Applied between UP-VUPC, ≤0.8 Volts Input OFF Voltage VCIN(off) V P-VVPC, UN- VN- WN-Br-VNC ≥9.0 Volts PWM Input Frequency fPWM Using Application Circuit ≤30 kHz Arm Shoot-through Blocking Time tDEAD Using Application Circuit of IPM's ≥2.0 µs Input Signal of Each Arm
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 COLLECTOR CURRENT, -IC, (AMPERES) REVERSE RECOVERY CURRENT, Irr, (AMPERES) REVERSE RECOVERY TIME, trr, (µs) 100 101 102 100 101 102 COLLECTOR CURRENT, -IC, (AMPERES) COLLECTOR CURRENT, IC, (AMPERES) SWITCHING LOSS, ESW(on), (mJ/PULSE) 100 101 102 SWITCHING LOSS (ON) VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART) COLLECTOR CURRENT, IC, (AMPERES) SWITCHING LOSS, ESW(off), (mJ/PULSE) SWITCHING LOSS (OFF) VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART) REVERSE RECOVERY CHARACTERISTICS (TYPICAL - INVERTER PART) EMITTER-COLLECTOR VOLTAGE, VEC, (VOLTS) COLLECTOR CURRENT, -IC, (AMPERES) FREE-WHEEL DIODE FORWARD CHARACTERISTICS (TYPICAL - INVERTER PART) 0 2.01.51.00.5 102 101 100 VD = 15V Tj = 25°C Tj = 125oC SUPPLY VOLTAGE, VD, (VOLTS) COLLECTOR-EMITTER SATURATION VOLTAGE, VCE(sat), (VOLTS) COLLECTOR-EMITTER SATURATION VOLTAGE VS. SUPPLY VOLTAGE CHARACTERISTICS (TYPICAL - INVERTER PART) 12 16 1 817 IC = 50A Tj = 25oC Tj = 125oC 1514130 60502010 30 40 REVERSE RECOVERY CHARACTERISTICS (TYPICAL - INVERTER PART) COLLECTOR-EMITTER VOLTAGE, VCE, (VOLTS) COLLECTOR CURRENT, IC, (AMPERES) OUTPUT CHARACTERISTICS (TYPICAL - INVERTER PART) VD = 17V Tj = 25°C 100 101 102 10-1 COLLECTOR CURRENT, IC, (AMPERES) SWITCHING TIMES, ton, (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART) 100 101 VCC = 300V VD = 15V Tj = 25°C Tj = 125oC INDUCTIVE LOAD COLLECTOR-CURRENT, IC, (AMPERES) COLLECTOR-EMITTER SATURATION VOLTAGE, VCE(sat), (VOLTS) COLLECTOR-EMITTER SATURATION VOLTAGE CHARACTERISTICS (TYPICAL - INVERTER PART) VD = 15V Tj = 25°C Tj = 125oC VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 1.5 0.5 1.0 2.0 1.5 0.5 1.0 2.0 101 100 10-1 10-2 102 101 100 10-1 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 101 100 10-1 10-2 100 101 102 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 101 100 10-1 10-2
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 TIME, (s) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (IGBT & FWDi - INVERTER PART) 101 10-110-210-3 100 101 100 10-1 10-3 10-2 Zth = Rth • (NORMALIZED VALUE) Single Pulse TC = 25°C Per Unit Base = Rth(j-c) = 0.95°C/W (IGBT) Rth(j-c) = 1.61°C/W (FWDi) NORMALIZED TRANSIENT THERMAL IMPEDANCE, Zth(j-c') 100 101 102 10-2 COLLECTOR CURRENT, IC, (AMPERES) SWITCHING TIMES, tc(on), (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART) 10-1 100 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 100 101 102 10-2 COLLECTOR CURRENT, IC, (AMPERES) SWITCHING TIMES, tc(off), (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART) 10-1 100 COLLECTOR CURRENT, IC, (AMPERES) SWITCHING TIMES, toff, (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL - INVERTER PART) 100 101 102 10-1 100 101 VCC = 300V VD = 15V Tj = 25°C Tj = 125oC INDUCTIVE LOAD VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD FORWARD CURRENT, IF, (AMPERES) REVERSE RECOVERY SWITCHING LOSS, Err, (mJ/PULSE) 100 101 102 REVERSE RECOVERY LOSS CHARACTERISTICS (TYPICAL - INVERTER PART) VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 100 10-1 10-2 10-3 FORWARD VOLTAGE DROP, VFM, (VOLTS) FORWARD CURRENT, IF, (AMPERES) FREE-WHEEL DIODE FORWARD CHARACTERISTICS (TYPICAL - UPPER ARM OF CONVERTER PART) 102 101 100 VD = 15V Tj = 25°C Tj = 125oC REVERSE RECOVERY TIME, Irr, (µs) 100 101 102 FORWARD CURRENT, IF, (AMPERES) REVERSE RECOVERY CHARACTERISTICS (TYPICAL - UPPER ARM OF CONVERTER PART) 102 101 100 10-1 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD REVERSE RECOVERY TIME, trr, (µs) 100 101 102 FORWARD CURRENT, IF, (AMPERES) REVERSE RECOVERY CHARACTERISTICS (TYPICAL - UPPER ARM OF CONVERTER PART) 101 100 10-1 10-2 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD FORWARD CURRENT, IF, (AMPERES) REVERSE RECOVERY EMMITER CURRENT, Err, (mJ/PULSE) 100 101 102 REVERSE RECOVERY LOSS CHARACTERISTICS (TYPICAL - UPPER ARM OF CONVERTER PART) VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 100 10-1 10-2 10-3
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM50B5LA060 / PM50B5LB060 Photo Voltaic IPM H-Bridge + 1 Chopper COLLECTOR CURRENT, IC, (AMPERES) SWITCHING LOSS, ESW(on), (mJ/PULSE) 100 101 102 SWITCHING LOSS (ON) VS. COLLECTOR CURRENT (TYPICAL - LOWER ARM OF CONVERTER PART) 101 100 10-1 10-2 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD COLLECTOR CURRENT, IC, (AMPERES) SWITCHING LOSS, ESW(off), (mJ/PULSE) 100 101 102 SWITCHING LOSS (ON) VS. COLLECTOR CURRENT (TYPICAL - LOWER ARM OF CONVERTER PART) 101 100 10-1 10-2 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 100 101 102 10-2 COLLECTOR CURRENT, IC, (AMPERES) SWITCHING TIMES, tc(on), (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL - LOWER ARM OF CONVERTER PART) 10-1 100 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 100 101 102 10-2 COLLECTOR CURRENT, IC, (AMPERES) SWITCHING TIMES, tc(off), (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL - LOWER ARM OF CONVERTER PART) 10-1 100 VCC = 300V VD = 15V Tj = 25°C Tj = 125°C INDUCTIVE LOAD 100 101 102 10-1 COLLECTOR CURRENT, IC, (AMPERES) SWITCHING TIMES, ton, (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL - LOWER ARM OF CONVERTER PART) 100 101 VCC = 300V VD = 15V Tj = 25°C Tj = 125oC INDUCTIVE LOAD 100 101 102 10-1 COLLECTOR CURRENT, IC, (AMPERES) SWITCHING TIMES, toff, (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL - LOWER ARM OF CONVERTER PART) 100 101 VCC = 300V VD = 15V Tj = 25°C Tj = 125oC INDUCTIVE LOAD TIME, (s) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (IGBT & FWDi UPPER ARM CONVERTER PART) 101 10-110-210-3 100 101 100 10-1 10-3 10-2 Zth = Rth • (NORMALIZED VALUE) Single Pulse TC = 25°C Per Unit Base = Rth(j-c) = 0.95°C/W (IGBT) Rth(j-c) = 0.95°C/W (FWDi) NORMALIZED TRANSIENT THERMAL IMPEDANCE, Zth(j-c') TIME, (s) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (IGBT & FWDi LOWER ARM CONVERTER PART) 101 10-110-210-3 100 101 100 10-1 10-3 10-2 Zth = Rth • (NORMALIZED VALUE) Single Pulse TC = 25°C Per Unit Base = Rth(j-c) = 0.95°C/W (IGBT) Rth(j-c) = 1.61°C/W (FWDi) NORMALIZED TRANSIENT THERMAL IMPEDANCE, Zth(j-c')