Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272Intellimod™ Module Single Phase IGBT Inverter Output

300 Amperes/1200 Volts

Description: Powerex Intellimod™ Intelligent Power Modules are isolated base modules designed for power switching applications operating at frequencies to 20kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free-wheel diode power devices. Features: □ Complete Output Power Circuit □ Gate Drive Circuit □ Protection Logic – Short Circuit – Over Temperature – Under Voltage Applications: □ Inverters □ UPS □ Motion/Servo Control □ Power Supplies Ordering Information: Example: Select the complete part number from the table below -i.e. PM300DVA120 is a 1200V,

300 Ampere Intellimod™ Intelligent

Power Module. Type Current Rating V CES Amperes Volts (x 10) PM 300 120 Outline Drawing and Circuit Diagram Dimensions Inches Millimeters A 4.72 120.0 B 3.54 90.0 D 4.17 ±0.010 106.0 ±0.25 E 2.99 ±0.010 76.0 ±0.25 F 1.52 38.5 G 0.16 4.0 H 0.16 4.01 J 0.40 10.16 K 0.71 18.0 L 1.22 31.0 M 1.73 44.0 N 0.12 3.0 Dimensions Inches Millimeters P 1.22 31.0 Q 1.10 28.0 R 0.12 3.0 S M8 Metric M8 T 0.26 Dia. Dia. 6.5 U 1.29 32.8 V 0.10 2.54 W 0.025 SQ 0.64 SQ X 0.14 Dia. 3.5 Dia. Y 0.26 Dia. Dia. 6.5 Z 1.79 45.5 AA 1.5 38.0 T - (4 TYP .) S - NUTS (3 TYP) C2E1 E2 C1 P A B C D E G L K K K Q Q P N F AA J V H R X (2 PLS) W SQ PIN (10 PLS) U Y M Z TEMP CC TH FSCV AMP RG OUT2 SINK GND SENS OUT1 V NI RSF O C C C2E1 C1 VFSCVV RREF SINK GND AMP RG OUT2 SENS OUT1 TEMP VC C NI RSF O NC NR N1 NO N1 i PC PO P1 PR P1 i RFO RFO 43 2 5 1 43 2 5 1

Intellimod™ Module Single Phase IGBT Inverter Output Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Absolute Maximum Ratings, Tj = 25°C unless otherwise specified Characteristics Symbol PM300DVA120 Units Power Device Junction Temperature T j -20 to 150 °C Storage Temperature T stg -40 to 125 °C Case Operating Temperature T C -20 to 100 °C Mounting Torque, M6 Mounting Screws (Typical) — 26 in-lb Mounting Torque, M6 Main Terminal Screws (Typical) — 26 in-lb Module Weight (T ypical) — 720 Grams Supply Voltage (Applied between C1-E2) V CC(surge) 1000 Volts Supply Voltage Protected by SC (VD = 13.5 ~16.5V, Inverter Part, Tj = 125°C Start) V CC(prot.) 800 Volts Isolation Voltage, AC 1 minute, 60Hz Sinusoidal V RMS 2500 Volts Control Sector Supply Voltage Applied between (VP1-VPC , VN1 -VNC )V D 20 Volts Input Voltage Applied between (CP1-VPC , CN1 -VNC )V CIN 10 Volts Fault Output Supply Voltage (Applied between FPO -VPC , FNO -VNC )V FO 20 Volts Fault Output Current (Sink Current at FO Terminals) I FO 20 mA IGBT Inverter Sector Collector-Emitter Voltage (VD = 15V, VCIN = 5V) V CES 1200 Volts Collector Current, ± (TC = 25°C) I C 300 Amperes Peak Collector Current, ± (TC = 25°C) I CP 600 Amperes Collector Dissipation (TC = 25°C) P C 1380 Watts

Intellimod™ Module Single Phase IGBT Inverter Output Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units Control Sector Short Circuit Trip Level SC -20 °C ≤ Tj ≤ 125°C, VD = 15V 380 —— Amperes Short Circuit Current Delay Time t off(SC) VD = 15V — 10 — µS Over Temperature Protection OT Trip Level 100 110 120 °C (VD = 15V, Lower Arm) OT r Reset Level 85 95 105 °C Supply Circuit Under Voltage Protection UV Trip Level 11.5 12.0 12.5 Volts (-20°C ≤ Tj ≤ 125°C) UV r Reset Level — 12.5 — Volts Circuit Current I D VD = 15V, VCIN = 5V, VN1 -VNC — 37 48 mA VD = 15V, VCIN = 5V, VP1-VPC — 37 48 mA Input ON Threshold Voltage V CIN(on) Applied between 1.2 1.5 1.8 Volts Input OFF Threshold Voltage V CIN(off) C P1-VPC , CN1 -VNC 1.7 2.0 2.3 Volts Fault Output Current I FO(H) VD = 15V, VFO = 15V —— 0.01 mA IFO(L) VD = 15V, VFO = 15V — 10 15 mA Minimum Fault Output Pulse Width t FO VD = 15V 1.0 1.8 — mS SXR Terminal Output Voltage V SXR Tj ≤ 125°C, Rin = 6.8kΩ (SPR , SNR ) 4.5 5.1 5.6 Volts

Intellimod™ Module Single Phase IGBT Inverter Output Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units IGBT Inverter Sector Collector-Emitter Cutoff Current I CES VCE = VCES , VD = 5V, Tj = 25°C —— 1.0 mA VCE = VCES , VD = 5V, Tj = 125°C —— 10.0 mA FWDi Forward Voltage V EC -IC = 300A, VD = 15V, VCIN = 5V — 2.50 3.50 Volts Collector-Emitter Saturation Voltage V CE(sat) VD = 15V, VCIN = 0V, IC = 300A, — 2.65 3.30 Volts Pulsed, Tj = 25°C VD = 15V, VCIN = 0V, IC = 300A, — 2.75 3.35 Volts Pulsed, Tj = 125°C Inductive Load Switching Times t on 0.4 0.9 2.3 µS trr VD = 15V, VCIN = 0V ~ 5V — 0.2 0.3 µS tC(on) VCC = 600V, IC = 300A, — 0.4 1.0 µS toff Tj = 125°C — 2.4 3.4 µS tC(off) — 0.7 1.2 µS Thermal Characteristics Characteristic Symbol Condition Min. Typ. Max. Units Junction to Case Thermal Resistance R th(j-c)Q Each Inverter IGBT —— 0.09 °C/Watt R th(j-c)D Each Inverter FWDi —— 0.13 °C/Watt Contact Thermal Resistance R th(c-f) Case to Fin Per Module, —— 0.033 °C/Watt Thermal Grease Applied Recommended Conditions for Use Characteristic Symbol Condition Value Units Supply Voltage V CC Applied across C1-E2 Terminals ≤ 800 Volts VCE(surge) Applied across C1-E1, C2-E2 Terminals ≤ 1000 Volts VD Applied between 15 ± 1.5 Volts VP1-VPC , VN1 -VNC Input ON Voltage V CIN(on) Applied between ≤ 0.8 Volts Input OFF Voltage V CIN(off) C P1-VPC , CN1 -VNC ≥ 4.0 Volts Arm Shoot-Through Blocking Time t DEAD For IPM's each Input Signal ≥ 3.5 µS

Intellimod™ Module Single Phase IGBT Inverter Output Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 COLLECTOR CURRENT, I C , (AMPERES) COLLECTOR-EMITTER VOLTAGE, V CE(SAT), (VOLTS) SATURATION VOLTAGE CHARACTERISTICS (TYPICAL) 0 200 400 600 2.0 VD = 15V 4.0 6.0 Tj = 25°C Tj = 125°C CONTROL SUPPLY VOLTAGE, V D , (VOLTS) COLLECTOR-EMITTER SATURATION VOLTAGE, VCE(SAT), (VOLTS) COLLECTOR-EMITTER SATURATON VOLTAGE CHARACTERISTICS (TYPICAL) 0 1 31 51 7 2.0 4.0 6.0 IC = 200A Tj = 25°C Tj = 125°C COLLECTOR-EMITTER VOLTAGE, V CE(sat), (VOLTS) COLLECTOR CURRENT, I C , (AMPERES) OUTPUT CHARACTERISTICS (TYPICAL) 200 VD = 17V Tj = 25oC 400 600 COLLECTOR CURRENT, I C , (AMPERES) SWITCHING TIMES, ton, toff, (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) 101 101 102 103 100 10-1 ton VCC = 600V VD = 15V toff Tj = 25°C Tj = 125°C COLLECTOR CURRENT, I C , (AMPERES) SWITCHING TIMES, tc(on), tc(off), (µs) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) 101 101 102 103 100 10-1 VCC = 600V VD = 15V Tj = 25°C Tj = 125°C tc(on) tc(off) COLLECTOR CURRENT, I C , (AMPERES) SWITCHING ENERGY, P SW(on), PSW(off), (mJ/PULSE) SWITCHING LOSS CHARACTERISTICS (TYPICAL) 103 101 102 103 101 102 100 PSW(off) PSW(on) VCC = 600V VD = 15V Tj = 25°C Tj = 125°C COLLECTOR CURRENT, I C , (AMPERES) REVERSE RECOVERY TIME, t rr, (µS) REVERSE RECOVERY CURRENT VS. COLLECTOR CURRENT (TYPICAL) 101 101 102 103 10-1 10-2 Irr trr VCC = 600V VD = 15V Tj = 25°C Tj = 125°C 103 101 100 REVERSE RECOVERY CURRENT, I rr, (AMPERES) 100 102 DIODE FORWARD VOLTAGE, V EC , (VOLTS) DIODE FORWARD CURRENT, I E, (AMPERES) DIODE FORWARD CHARACTERISTICS 103 102 101 Tj = 25°C Tj = 125°C VD = 15V 0 1.0 2.0 3.0 CARRIER FREQUENCY, f C , (kHz) CIRCUIT CURRENT, ID , (mA) CIRCUIT CURRENT VS. CARRIER FREQUENCY 0 1 02 03 0 VD = 15V Tj = 25°C

Intellimod™ Module Single Phase IGBT Inverter Output Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 -60 -60 -60 TIME, (s) TRANSIENT IMPEDANCE, Z th(j-c), (NORMALIZED VALUE) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (IGBT) 101 10-1 100 10 1 100 10-1 10-2 10-3 10-210-3 SINGLE PULSE STANDARD VALUE = R th(j-c)Q = 0.09°C/W TIME, (s) TRANSIENT IMPEDANCE, Z th(j-c), (NORMALIZED VALUE) TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (FWDi) 101 10-1 100 10 1 100 10-1 10-2 10-3 10-210-3 SINGLE PULSE STANDARD VALUE = R th(j-c)D = 0.13°C/W CONTROL SUPPLY VOLTAGE, V D, (VOLTS) SHORT CIRCUIT CURRENT TRIP LEVEL, (V D = 1EV) = 1.0 OVER CURRENT TRIP LEVEL VS. SUPPLY VOLTAGE (TYPICAL) 0 1 31 51 7 0.8 1.0 1.2 Tj = 25°C JUNCTION TEMPERATURE, T j, (°C) SHORT CIRCUIT CURRENT TRIP LEVEL, (T j = 25°C) = 1.0 OVER CURRENT TRIP LEVEL TEMPERATURE DEPENDENCY (TYPICAL) 20 100 180 0.8 1.0 1.2 VD = 15V JUNCTION TEMPERATURE, T j, (°C) FAULT OUTPUT PULSE WIDTH TRIP LEVEL, tFO (Tj = 25°C) = 1.0 FAULT OUTPUT PULSE WIDTH VS. TEMPERATURE (TYPICAL) 20 100 180 0.8 1.0 1.2 VD = 15V JUNCTION TEMPERATURE, T j, (°C) SUPPLY CIRCUIT UNDER VOLTAGE PROTECTION, TRIP RESET LEVEL, UVt, UVr, (VOLTS) CONTROL SUPPLY VOLTAGE TRIP-RESET LEVEL TEMPERATURE DEPENDENCY (TYPICAL) 20 100 180 VD = 15V UV t UV r