DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

rated voltage 275 VAC 50/60 Hz (ENEC)

280 VAC 50/60 Hz (UL, cUL)

capacitance range 0.01 – 10.0 µF capacitance tolerance ± 20% standard, ± 10% option, ± 5% on request temperature range –55 to +105°C climatic category 55/105/56/B approvals ENEC, UL, cUL dissipation factor Maximum values at +23°C C ≤ 0.1 µF 0.1µF < C ≤ 1 µF C > 1 µF 100 kHz 0.6% – – test voltage between The 100% screening factory test is carried out at 2200 terminals VDC. The voltage level is selected to meet the requirements in applicable equipment standards. All electrical characteristics are checked after the test. insulation resistance C ≤ 0.33 µF: ≥ 30 000 MΩ C > 0.33 µF: ≥ 10 000 s in dc applications Recommended voltage ≤ 760 VDC pHE840m

  • Emi suppressor , class x2, metallized polypropylene
  • 0.01 – 10.0 µf, 275/280 vac, +105°c
  • small dimensions including low profile capacitors tYpiCaL appLiCations ConstRuCtion tECHniCaL data For worldwide use as electromagnetic interference suppressor in all X2 and across-the-line applications. Metallized polypropylene film encapsulated with selfextinguishing epoxy resin in a box of material recognized to UL 94 V–0. p d std l max l b 7.5 ± 0.4 0.6 17 20 ±0.4 10.0 ± 0.4 0.6 17 30 ±0.4 15.0 ± 0.4 0.8 17 30 ±0.4 22.5 ± 0.4 0.8 6 30 ±0.4 27.5 ± 0.4 0.8 6 30 ±0.4 37.5 ± 0.5 1.0 6 30 ±0.7 Tolerance in lead length < 30 mm mm 30 mm mm L H B p l∅ d 0.5 b EnViRonmEntaL tEst data Endurance EN/IEC 60384-14:2005 1.25 x UR VAC 50 Hz, once every hour increased to 1000 VAC for 0.1 s, 1000 h at upper rated temperature vibration IEC 60068–2–6 3 directions at 2 hours each, No visible damage Test Fc 10–55 Hz at 0.75 mm or 98 m/s2 No open or short circuit Bump IEC 60068–2–29 1000 bumps at No visible damage Test Eb 390 m/s2 No open or short circuit change of temperature IEC 60068–2–14 Upper and lower rated No visible damage Test Na temperature 5 cycles active flammability EN/IEC 60384-14:2005 Passive flammability Enclosure material ofEN/IEC 60384-14:2005 UL94V–0 flammability class humidity IEC 60068-2-3 +40°C and 56 days Test Ca 90 – 95% R.H. Not for use in series with the mains. See www.kemet.com for more information.

lEad sPacinG 7.5 mm 0.010 K01 4.0 8.0 10.0 14 100 PHE840MK5100MK01R17 0.012 K01 4.0 8.0 10.0 13 100 PHE840MK5120MK01R17 0.015 K01 4.0 8.0 10.0 12 100 PHE840MK5150MK01R17 0.018 K03 5.0 11.0 10.0 11 100 PHE840MK5180MK03R17 0.022 K03 5.0 11.0 10.0 10 100 PHE840MK5220MK03R17 lEad sPacinG 10 mm lEad sPacinG 15 mm appRoVaLs certification Body specification ENEC EN/IEC 60384-14:2005 UL UL 60384-14 CAN/CSA-E60384-14:09

oRdERing inFoRmation

  • RIFA
  • RIFA article code
  • Rated capacitance
  • Capacitance tolerance code
  • Rated voltage
  • X2
  • Approval marks
  • Manufacturing date code
  • IEC climatic category
  • Passive flammability class The article code for the standard part is given in the article table. lEad sPacinG 22.5 mm lEad sPacinG 27.5 mm lEad sPacinG 37.5 mm * Only ± 20% tolerance capaci- Box max dimensions max tance code in mm fo du/dt article code µf B h l mhz v/µs capaci- Box max dimensions max tance code in mm fo du/dt article code µf B h l mhz v/µs Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applic ations, but are not intended to constitute – and we specifically disclaim – any warranty concerning suitabi lity for a specific customer application or use. This Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice in ferred from this Inform ation or otherwise provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the ad vice given or results obtained. (UR = 280 VAC) (UR = 280 VAC)