PHE840EA5100MA01R17 KEMET | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
rated voltage 300 VAC 50/60 Hz capacitance range 0.01 – 10 µF capacitance tolerance ± 20% standard, ± 10% option temperature range –55 to +105°C climatic category 55/105/56/B approvals ENEC, UL, cUL related to rated voltage and climatic category dissipation factor tanδ Maximum values at +23°C C ≤ 0.1 µF 0.1µF < C ≤ 1 µF C > 1 µF 100 kHz 0.6% – – test voltage between The 100% screening factory test is carried out at terminals 2200 VDC. The voltage level is selected to meet the requirements in applicable equipment standards. All electrical characteristics are checked after the test. resonance frequency Tabulated self-resonance frequencies f0 refer to 5 mm lead length. insulation resistance C ≤ 0.33 µF: ≥ 30 000 MΩ C > 0.33 µF: ≥ 10 000 ΩF in dc applications Recommended voltage ≤ 760 VDC pHE840E
- Emi suppressor, class x2, metallized polypropylene
- 0.01 – 10 µf, 300 vac, +105°c
- new improved design: small dimensions including low profile capacitors tYpiCaL appLiCations ConstRuCtion tECHniCaL data For worldwide use as electromagnetic interference suppressor in all X2 and across-the-line applications. encapsulated in self-extinguishing material meeting the requirements of UL 94 V–0. EnViRonmEntaL tEst data Endurance EN/IEC 60384-14:2005 1.25 x UR VAC 50 Hz, once every hour increased to 1000 VAC for 0.1 s, 1000 h at upper rated temperature vibration IEC 60068–2–6 3 directions at 2 hours each, No visible damage Test Fc 10–55 Hz at 0.75 mm or 98 m/s2 No open or short circuit Bump IEC 60068–2–29 1000 bumps at No visible damage Test Eb 390 m/s2 No open or short circuit change of temperature IEC 60068–2–14 Upper and lower rated No visible damage Test Na temperature 5 cycles active flammability EN/IEC 60384-14:2005 Passive flammability EN/IEC 60384-14:2005 Enclosure material of UL1414 UL94V–0 flammability class humidity IEC 60068-2-3 +40°C and 56 days Test Ca 90 – 95% R.H. P d std l max l b 10.0 ± 0.4 0.6 17 30 ±0.4 15.0 ± 0.4 0.8 17 30 ±0.4 22.5 ± 0.4 0.8 6 30 ±0.4 27.5 ± 0.4 0.8 6 30 ±0.4 37.5 ± 0.5 1.0 6 30 ±0.7 Tolerance in lead length < 30 mm mm 30 mm mm L H B p l∅ d 0.5 b Not for use in series with the mains. See www.kemet.com for more information. Metallized polypropylene winding,
certification Body specification ENEC EN/IEC 60384-14:2005 UL UL 1283 UL 1414 (UR = 250 VAC) cUL recognition C 22.2 No. 8 C 22.2 No. 1
oRdERing inFoRmation
- RIFA
- RIFA article code
- Rated capacitance
- Capacitance tolerance code
- Rated voltage
- X2
- Approval marks
- Manufacturing date code
- IEC climatic category
- Passive flammability class The article code for the standard part is given in the article table. For other options, see page 11. PhE840E aRtiCLE taBLE capaci- Box max dimensions max tance code in mm fo du/dt article code µf B h l mhz v/µs capaci- Box max dimensions max tance code in mm fo du/dt article code µf B h l mhz v/µs lEad sPacinG 10 mm 0.010 A01 4.0 9.0 13.0 11 100 PHE840EA5100MA01R17 0.012 A01 4.0 9.0 13.0 10 100 PHE840EA5120MA01R17 lEad sPacinG 15 mm lEad sPacinG 22.5 mm lEad sPacinG 22.5 mm lEad sPacinG 27.5 mm lEad sPacinG 37.5 mm 10 R08 28.0 43.0 41.0 0.26 100 PHE840ER8100MR08R06L2 * Only ± 20% tolerance Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applic ations, but are not intended to constitute – and we specifically disclaim – any warranty concerning suitabi lity for a specific customer application or use. This Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice in ferred from this Inform ation or otherwise provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the ad vice given or results obtained.