OPERATION & MAINTENANCE INSTRUCTIONS DL1225 3KVA PETROL GENERATOR MODEL NO: PG3800A PART NO: 8857852
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INTRODUCTION Thank you for purchasing this CLARKE 3kVA Petrol Generator. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights. ENVIRONMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com GENERAL SAFETY RULES WORK AREA
- Always use in a well ventilated area.
- Always position the exhaust outlet away from people.
- Never use indoors or in a confined space.
- Read these safety instructions before using the equipment.
- Keep children away from the generator. POSITIONING THE GENERATOR 1. Always leave a least a 1m gap between the generator and any surrounding building or structures. 2. Always ensure the generator is on a solid, flat surface. 3. Always ensure the surrounding area is free from any material that could burn or be damaged by heat. 4. Never move or tilt the generator whilst it is switched on. FIRE PREVENTION 1. Always switch the engine OFF when refuelling. 2. Always refuel away from any source of heat. 3. Always refuel in a well ventilated area. 4. Only use standard unleaded petrol. 5. Never smoke whilst refuelling and avoid smoking or using a naked flame near the generator. 6. Never start the engine if there is spilled fuel. Any spillage must be wiped clean and the generator allowed to dry before attempting to start the engine. WARNING: EXHAUST FUMES CAN BE EXTREMELY DANGEROUS IF INHALED
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com PREVENTION OF ELECTRIC SHOCK 1. Never use the generator in wet conditions unless it is well protected/covered. Under these conditions, adequate ventilation MUST be provided. 2. Never operate the generator with wet hands. 3. Never use water or any other liquids to clean the generator. ADDITIONAL SAFETY RULES FOR GENERATORS 1. Always ensure the applied load does not exceed the generator rating. Overloading the generator is dangerous and could cause serious damage. 2.Always disconnect the generator when carrying out any maintenance. 3. Always ensure the generator reaches operating speed before connecting a load. 4. Never allow the generator to run out of fuel when a load is connected. 5. Never transport the generator with fuel in the tank. 6. Do Not connect to a commercial or residential power supply; e.g. ring main. 7. Never allow the generator air vents to become blocked.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SAFETY SYMBOLS Read Instruction manual before use Flammable Caution - The user should be aware of a general hazard Hot Surface - Do not touch Dangerous voltage Poisonous fumes - Do not use the generator in an enclosed space.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com GENERATOR OVERVIEW NO DESCRIPTION NO DESCRIPTION
1 Fuel Supply Valve 7 Engine Switch
2 Fuel Tank Cap 8 Anti-vibration Feet
3 Fuel Level Gauge 9 Dipstick
4 Frame 10 Control Panel
5 Air Filter 11 Choke Lever
6 Starting Handle 12 Earth Point
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com UNPACKING AND ASSEMBLY Unpack your generator and check to ensure the following items are present. Should there be any deficiency or damage caused during transit contact your CLARKE dealer immediately. BEFORE USING THE GENERATOR Attach a suitable earth lead to a good earthing point - water pipe, ground spike etc., whenever you use this generator. Before using your generator check that:
- The generator is in good condition and free from any damage.
- The generator is clean and free from fuel or oil spillage.
- The generator is correctly located for use (See page 3).
- The fuel system is intact and there is no leakage. NOTE: Always use a funnel to fill the fuel tank to avoid accidental spillage of fuel. If fuel is spilled it must be cleaned up before use.
- The generator • Spark plug box spanner
- Tommy bar • 12 Volt D.C. output lead assembly WARNING: ENSURE THERE IS ADEQUATE FUEL IN THE TANK WHEN USING THE GENERATOR. RUNNING OUT OF FUEL OR STOPPING THE ENGINE SUDDENLY WITH A LOAD CONNECTED COULD CAUSE SERIOUS DAMAGE.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com EARTH POINT 1. Ground the generator by connecting a suitable grounding wire to the earth point. NOTE: Connect the other end of the grounding wire to a copper or brass grounding rod that is driven into the earth. CHECKING THE ENGINE OIL LEVEL 1. Turn the dipstick anti-clockwise and remove from the oil fill tube. 2. Wipe the dipstick with a clean cloth. 3. Insert the dipstick back into the oil fill tube and then remove it again. Do not screw in the oil filler cap/dipstick when doing this. WARNING: FAILURE TO PROPERLY GROUND THE GENERATOR CAN RESULT IN ELECTROCUTION WARNING: TO CARRY OUT THIS CHECK, PLACE THE GENERATOR ON LEVEL GROUND WITH THE ENGINE SWITCHED OFF. WARNING: TAKE CARE NOT TO TOUCH ANY HOT PARTS OF THE GENERATOR WHEN CHECKING THE OIL LEVEL.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 4. If the oil level is at or below the ‘L’ mark on the dipstick, add oil to the crankcase.
- Fill until the oil reaches the threads in the oil fill tube.
- Oil capacity (See page 20).
- We recommend the use of SAE10W30 oil (Part No: 3050845) in this generator. available from your CLARKE dealer. 5. Replace the oil filler cap. CHECKING THE FUEL LEVEL 1. Check the fuel level on the fuel gauge. The fuel gauge will show as red when you have fuel in the tank turning white as the fuel level decreases. 2. To add fuel, open the fuel filler cap. 3. Just inside the fuel tank is a fuel filter which catches any contaminants as you refuel. 4. Slowly add fuel to the fuel tank (maximum 15L) watching the fuel level gauge as you do so. Empty Full Fuel filter
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com RECOMMENDED FUEL We recommend the use of standard unleaded petrol. NOTE: Do not overfill the fuel tank. 5. Replace the fuel filler cap securely. USING YOUR GENERATOR STARTING THE ENGINE 1. Remove all connections from the AC sockets. 2. Set the fuel valve to the ON position as shown. 3. Make sure that the AC breaker is set to the off (down) position. 4. Move the choke lever to the ‘Choke’ position. WARNING: ALWAYS REFUEL IN A WELL VENTILATED AREA AWAY FROM ANY HEAT SOURCES. WARNING: ALLOW THE UNIT TO COOL DOWN BEFORE REFUELLING. WARNING: DO NOT LEAVE FUEL WITHIN THE REACH OF CHILDREN.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 5. Set the engine switch to ‘ON’. 6. Hold the generator steady and pull the starting handle lightly until you start to feel resistance. Then pull sharply to start the engine. NOTE: You may have to do this more than once. NOTE: When you first start the generator, the overload indicator may light up for a few seconds, this is normal. If the overload indicator is still lit after 5 seconds, stop the engine and contact your CLARKE dealer. 7. Once the engine has warmed up, move the choke lever to the “run” position. WARNING: ONCE THE GENERATOR HAS STARTED, RELEASE THE STARTING HANDLE SLOWLY TO AVOID INJURY/DAMAGE AS IT RECOILS.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CONNECTING ELECTRICAL APPLIANCES The generator can supply both 230V AC and 12V DC AC POWER 1. Start the engine. See page 10 2. Make sure that the AC Breaker is set to the ON (up) position. 3. Connect the appliance to the generator.
- Make sure the appliance is turned off before connecting it to the generator.
- The voltage being supplied is shown on the voltmeter. AC BREAKER The AC Breaker will activate if the generator is overloaded, If the AC Breaker activates, 1. Remove any connected devices from the generator 2. Wait for a few minutes 3. Set the AC breaker to the ON (up) position. 4. Reconnect the devices to the generator, making sure your do not exceed the maximum capacity of the generator. CAUTION: MAKE SURE THAT THE APPLIANCE BEING CONNECTED IS IN GOOD WORKING ORDER, IF IT BEGINS TO ACT ABNORMALLY OR STOPS SUDDENLY, DISCONNECT IT FROM THE GENERATOR CAUTION: MAKE SURE THE APPLIANCE DOES NOT EXCEED THE MAXIMUM RATED LOAD FOR THE GENERATOR. CAUTION: ANY DEVICE WHICH CONTAINS AN INDUCTIVE LOAD E.G. DEVICES THAT CONTAIN A MOTOR MAY REQUIRE MORE CURRENT ON STARTUP.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DC POWER 1. Start the generator. See page 10 2. Make sure the appliance is turned off before connecting it to the generator. 3. Connect the 12V DC appliance (max 8.3A) to the generator. DC POWER (CHARGING CAR BAT- TERIES) 1. Start the generator. See page 10 2. Connect the battery charging leads to the battery.
- Make sure you clamp the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the battery. 3. Connect the battery charging leads to the generator.
- The battery will begin to charge 4. Monitor the voltage across the battery regularly during charging and disconnect the battery when the voltage reaches 14.4 volts.
- Do not allow the clamps to touch each other whilst connected to the generator. DC OVERLOAD PROTECTOR If the DC overload protector activates, wait for a few minutes and then press the reset button shown on the right. WARNING: FOR YOUR SAFETY PERFORM THE FOLLOWING INSTRUCTIONS IN THE ORDER SHOWN. WARNING: YOU SHOULD ONLY USE THIS GENERATOR TO ‘TOP UP’ THE BATTERY, ALSO TRYING TO CHARGE A COMPLETELY FLAT BATTERY MAY CAUSE THE FUSE TO BLOW. CAUTION: WHEN DISCONNECTING THE BATTERY, ALWAYS DISCONNECT THE NEGATIVE (BLACK) LEAD FIRST.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SHUTTING DOWN THE GENERATOR To stop the generator in an emergency simply set the engine switch to ‘OFF’. NOTE: Turn off any electric devices. 1. Disconnect any electric devices. 2. Make sure that the AC breaker is set to the off (down) position. 3. Set the engine switch to the “0” (OFF) position. 4. Set the fuel valve to the OFF position as shown.”.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com MAINTENANCE CHANGING THE ENGINE OIL 1. Unscrew and remove the oil filler cap/dipstick. 2. Place an oil collection tray under the drain plug. 3. Unscrew the drain plug and allow the used engine oil to drain from the crankcase into the oil collection tray. NOTE: Drain the engine oil when the engine is warm, this will ensure the oil flows out faster. 4. Replace the drain plug. 5. Fill the crankcase with engine oil.
- Fill until the oil reaches the threads in the oil fill tube.
- Oil capacity (See page 20.).
- We recommend the use of SAE10W30 oil (Part No: 3050845) in this generator. available from your CLARKE dealer. 6. Replace the dipstick. ENVIRONMENTAL PROTECTION One of the most damaging sources of pollution is oil, Do not throw away used engine oil in with your domestic rubbish or pour it down drains and sinks. Place it in a leak proof container and take it to your local waste disposal site. CAUTION: PROLONGED EXPOSURE TO USED ENGINE OIL IS DANGEROUS, ALWAYS WASH YOUR HANDS THOROUGHLY AFTER HANDLING USED ENGINE OIL.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CHANGING THE SPARK PLUG 1. Remove the spark plug cap from the spark plug. 2. Use the spark plug spanner supplied to remove the spark plug. 3. Remove any carbon that has accumulated around the electrode. 4. Check the spark plug gap (a), it should be between 0.7 and 0.8 mm, adjust if necessary. 5. Check the overall condition of the spark plug for erosion or pitting and replace if necessary. 6. Reinstall the spark plug and replace the spark plug cap. CAUTION: ALLOW THE ENGINE TO COOL BEFORE REMOVING THE SPARK PLUG. Add pic
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CHECKING THE AIR FILTER 1. Unclip and remove the air filter cover. 2. Remove the air filter element. 3. Make sure that the air filter is clean and not damaged.
- If the air filter is damaged contact CLARKE spare parts department for a replacement.
- If the filter is dirty, wash in a solution of warm water and mild detergent and rinse thoroughly. Leave the filter to dry completely, once it is dry immerse in clean engine oil and squeeze to remove excess oil. 4. Replace the filter to its original position and replace the air filter cover. CAUTION: DO NOT USE THE GENERATOR WITHOUT THE AIR FILTER FITTED, THIS CAN DAMAGE THE GENERATOR. WARNING: DO NOT USE INFLAMMABLE SOLVENTS OR PETROL TO CLEAN THE AIR FILTER.
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CLEANING THE FUEL VALVE FILTER / DRAINING THE FUEL TANK 1. Set the fuel supply valve to OFF. 2. Unscrew and remove the cup, then remove the valve filter and ‘O’ ring. 3. Wash these parts in a non- inflammable solvent. Make sure that the valve filter is not damaged. 4. Place an approved petrol storage container under the fuel valve and set the fuel supply valve to ‘ON’.
- The fuel in the tank will drain into the container. 5. Replace the ‘O’ ring and valve filter and tighten the cup as far as possible. VALVE FILTER ‘O’ RING CUP
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com TROUBLESHOOTING If this does not solve your problem, please contact the CLARKE service department. PROBLEM CAUSE SOLUTION The generator fails to start Ignition switch is off Set the ignition switch to ‘on’ Not enough oil in the generator Add more oil, See page 8 No fuel Add more fuel, See page 9 Spark plug not working correctly Change the spark plug, See page 16 The generator fails to generate electric- ity The device you are trying to power is faulty Make sure the device you want to power is working properly The AC breaker is switched off Switch the AC breaker on The generator is difficult to start The air filter is dirty Clean the air filter, See page 17 The fuel filter is blocked Clean the fuel filter, See page 18
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SPECIFICATIONS PG3800A Engine Engine Model PT170F1 Fuel Type Petrol Displacement (cm3) 212 cc Max. power output (hp/rpm) 5.6 @ 3000 rpm Start system Hand recoil Fuel tank capacity (L) 15 Fuel consumption (L/hr.) 1.9 Maximum run time (h) @75% Load 8.2 Engine oil type SAE10W30 Engine oil capacity (L) 0.61 Guaranteed sound power (LWA dB) 96 Generator Rated Frequency (Hz) 50 AC Output Voltage (V) 230 (13A) DC Output Voltage (V) 12V (Max 8.3A) Rated Power (W) 2700 Dimensions Length (mm) 600 Width (mm) 435 Height (mm) 445 Unpacked Weight (kg) 43.7
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com EXPLODED DIAGRAM
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com PARTS LIST Please quote the reference THPG380001 onwards. e.g. Fuel Filter will be THPG380021. No Description No Description
1 Switch 19 Bolt M6x25
2 Panel 20 Fuel Filler Cap
3 Voltmeter 21 Fuel Filter
4 AC Socket 22 Screw M5x12
5 AC Breaker 23 Fuel Gauge
6 Screw M3x8 24 Fuel Valve
7 Earth Bolt 25 Frame
8 DC Socket 26 Cross Beam
9 DC Breaker 27 Anti Vibration Foot (LH)
10 Panel Back Cover 28 Flange Nut M8
11 Wiring Loom 29 Rubber Feet
12 Bolt M6x12 30 Anti Vibration Foot (RH)
13 Bridge Pile 31 Back Guard Plate
14 Engine 32 Flange Bolt M6x12
15 Generator 33 Side Guard Plate
16 Fuel Tank 34 Flange Bolt M6x12
17 Rubber Gasket 35 Flange Bolt M6x35
18 Washer 36 Upper Guard Plate
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com DECLARATION OF CONFORMITY
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com