PFC350 TRUMPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
TRUMPower 350 WATT POWER FACTOR CORRECTED SUPPLIES el DESCRIPTION PFc350 SERIES C€ (LVD + EMC) The PFC350 series comprises single and multiple output models for 350 watts of continuous output power. All models meet EN 61000-3-2. All auxiliary A outputs are with magnetic amplifier to keep 424> regulation. The units are constructed on a printed CNIS lt circuit board with a U-bracket for mechnical iy’ ra 4 support and heat sinking. Both "B" and "C" versions ZS pe ety are with UL, CSA and TUV approvals. Wife eg? 2 ard Pr FEATURES Safety Standard Approvals: * Power Factor 0.98 typical AL UL 1950 * 90 VAC to 264 VAC universal input ® File No. E137410 + In compliance with EN 55024, EN 61000-3-2 and EN 61000.3-3 CBe C22.2 No. 950 * Overvoltage and thermal protection Certificate No. LR93632(157810) * Short-circuit protection + Power Fail Detect (PFD) signal A EN 60950 + 100% burn-in at full rated load tiv Certificate No. 9955628 * Remote sense on master output ENVIRONMENTAL SPECIFICATIONS Operating temperature: 0°C to +70 Storage temperature: -40C to +85 INPUT SPECIFICATIONS Relative humidity: 5% to 95% non-condensing Input voltage: 90 to 264 VAC Derating: Derate from 100% at 50 C Input frequency: 47 to 63 Hz linearly to 50% at 70 C Input current: 5.6A (rms) for 1ISVAC Cooling: 38 CFM forced air, provided 2.8A (rms) for 230VAC on "C" version, to be provided Leakage current: 0.4mA max. @115VAC, 60Hz for "B" version by user 0.8mA max. @230VAC, 50Hz GENERAL SPECIFICATIONS OUTPUT SPECIFICATIONS Switching frequency: 76KHz +/-8KHz Output voltage/current : See rating chart Power factor: 0.98 typical Total output Power: 350 watts maximum Efficiency : 70% typical Ripple and noise: == 2% peak to peak maximum Hold-up time : 12 msec minimum at 11SVAC Overvoltage protection : Provided on output #1 only; . . °. . set at 112-132 % of its Line regulation : +/-0.5% maximum at full load nominal output voltage Inrush current : 40 A @ 1ISVAC, or 80 A @ 230 Overcurrent protection: All outputs protected to VAC, at 25 © cold start short circuit conditions Withstand voltage: 3000VAC from input to output . , c : > from input to outpu Temperature coefficient: Ail outputs +/-0.04%/ C 1500VAC from input to ground maximun . . S00VAC from output to ground Transient response : Maximum excursion of 4% . or better on all models: MTBF : 350,000 hours minimum at full recovering to 1% of final load at 25 ambient, calculated value within 500us after a per MIL-HDBK-217F, excluding 25% step load change DC fan. PED signal : TTL logic high for normal . . - operation and TTL logic low EMI requirements: In compliance with EN 55022 upon loss of input power. and FCC, conducted emissions This signal appears at least meeting Class B and radiated 1 ms prior to +5.1V output emissions meeting Class A dropping 5% below its Safety reguirements : Meets or exceeds: nominal value. This signal (a) UL 1950 also provides a minimum delay of 100 ms after +5.1V (b) CSA C22.2 No. 950 is within regulation. (c) IEC 950 (EN 60950) Tumbler Technologies/TRUMPower + Palo Alto, CA » 650-494-3322 + info@trumpower.com » www.TRUMPower.com
UNIVERSAL INPUT PFC350 SERIES ee OUTPUT VOLTAGE/CURRENT RATING CHART Maximum (1)(5) Output #1 Output #2 (2) Output #3 Output #4 (3) Output PFC350-10 5.1V 1A 539A 2% (NIA) (N/A) (NIA) T75W PFC350-12_12V_0.5A_29.2A_ 2% (N/A) (N/A) INA) 350W PFC350-13. 1SV 04A 234A 2% (N/A) (N/A) - (N/A) 350W PFC350-14 24V_0.A_ 146A 2% (N/A) (N/A) (N/A) 350W PFC350-16 30V 0.2A 117A 2% (NA) (NA) (NA) 350W PFC350-18 _48V_0.1A_7.3A_2% (N/A) (N/A) (N/A) 350W_ PFC350-23 *5.1V. SA 40A 2% +12V OA 9A 4% (N/A) (N/A) 300W PFC350-25 +5.1V 5A 40A 2% +24V 0A 45A 4% (N/A) (N/A) 300W PFC350-31 +5.1V 5A 40A 2% +12V 0A 9A 4% -12V 0A 4A 4% (N/A) 350W PFC350-33 +5.1V 5A 40A 2% +15V 0A 8A 4% -12V 0A 4A 4% (N/A) 350W PFC350-40 +5.1V SA 40A_2% +12V_0A__ 9A 4% -12V__ 0A 4A 4% SV OA OA 4% 3SOW PFC350-41 +5.1V 5A 40A 2% +I5V 0A 8A 4% -ISV OA 4A 4% 24V OA 4A 4% 350W PFC350-42 +5.1V__SA__40A_2% +12V_0A__9A_4% -12V__0A 4A 4% ~—12V_ OA 4A 4% SOW PFC350-44 +5.1V 5A 40A 2% +12V 0A 9A 4% -I5V. 0A 4A 4% SV OA 4A 4% | 350W PFC350-45 +5.1V 5A 40A 2% +12V OA 9A 4% -12V 0A 4A 4% 24V 0A 4A 4% = 350W Notes: (1) Add suffix "B" for U-bracket format or "C" for enclosed format, e.g. PFC350-45C. (2) The peak current of output #2 is limited to 12A on +12V, 9.6A on +15¥V or 6.0A on +24V. (3) Output #4 is floating. It can be connected externally for a positive or negative output. (4) Peak output current with 10% maximum duty cycle for less than 60 seconds. Total peak power must not exceed 350 watts. (5) All models may be operated at no-load. At no-load, output voltage tolerance increases to 10%. The output #1 of multiple output models requires 5A to support other outputs at their maximum rated loads. MECHANICAL SPECIFICATIONS Single Output Models 9.92 [252.0] fe 7 5 cal — 105, sl sla hd ise EP rpe se Q AS p asa IP S}3/2 SISK l x e}c HX NOTES: | ol |r Gs) 1. Dimensions shown in inch [mm] vl ed o 2d QRS 2. Tolerance 0.02 [0.5] maximum. Cs | AO >) ; ; Bt RS a 3. Pl input connector is Beau Inc. P/N 72-5-03C. t __@ SS 8 Screws are #6-32 on 0.375 inch (9.53mm) centers. 4. P2 is for DC fan rated 24V/0.12A (models MOUNTING HOLE: THREADED PFC350-14,16) or 12V/0.22A (the other models). INSERT FOR #8-32 OR M4*0.7 5. P3 Connector mates with Molex housing 22-01-1043 SCREWS (6 PLS). and Molex 40445 series crimp terminal. 6. Main output studs HS7/HS8 are with M5*0.8 screws = > ——, 7. Weight: " ol * ae = at—> ee — 1,47
9.92 [252.0] _| +t er. aioe f alstet| =:ep Rl] ol LDP =] oak NOTES: foal Bd ten i HX => is ?s 1, Dimensions shown in inch [mm]. S/S) S| are (E(t) ))) Blp> 2. Tolerance 0.02 [0.5] maximum. | «of 3! 2ey SRF] = 8 3. Pl input connector is Beau Inc. P/N 72-5-03C. as 3 a ee RE ee Screws are #6-32 on 0.375 inch (9.53mm) centers. & cae 2, i |__ ee 4. P2 Output connector is Dinkle P/N 166-06P. 5. P4 is for DC fan rated 24V/0.12A (model MOUNTING HOLE’ THREADED PFC350-25) or 12V/0.22A (the other models). INSERT FOR #8-32 OR M4*0.7 6. PS Connector mates with Molex housing 22-01-1043 SCREWS (6 PLS) and Molex 40445 series crimp terminal. 7. Main output studs HS7/HS8 are with MS5*0.8 screws. oT Sa, 8. Weight: On e “| =5| ei eS 1.47 PIN CHART Single Output Models eS HS7 Hs8 Ps feted fete ts | PFC350-12 PFC350-13 : PFC350-14 PFC350-16| uve | NEUTRAL! +sqvor | -s(vor | NC ee RETURN ourpur #1 PFC350-18 Multiple Output Models aw aS [com HS7 Hs8 Pepe fete pele Ts fe fete Pets | PFC350-23 PFC350-24}, | joureut|com “ 4 com PFC350-30 PFC350-31 7 ourrut|comJourrut| v6 |. s com OUTPUT #1 PFC350.32 PFC350.33| VE [NEUTRAL] GRoUND|OURUT Com JOURRUT) Nc | Nc. |+sqvon|-svon] peo | COM Jourpur#: | ReTuRN PFC350-40 PFC350-41 . OUTPUT PFC350-42 PFC350-44] Live |NeuTRAL|GROUND|OUTPUT|COM |OUTPUT|OUTPUT) 44 | -s¢yon)|-sqvon] PRD | COM PFC350-45 a2 [Ren | #3 #4 {RETURN RET Note: "OUTPUT #1 RETURN" is connected to "COM. RET" (common return), but "OUTPUT #4 RETURN" is isolated. CO oo