OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC06/24 POWERED AIR PURIFYING RESPIRATOR MODEL NO: PAPR1 PART NO: 6000719

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com INTRODUCTION Thank you for purchasing this CLARKE Respirator. Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. In doing so you will ensure the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service. PRODUCT DESCRIPTION This product helps protect the user from certain contaminants - the device is equipped with a particle filter to protect the user from airborne particles (solid and liquid aerosols). All users must read and understand these instructions and applicable health and safety standards. If you have questions about the type of respiratory equipment required, consult a technical expert. DO NOT enter a hazardous area until you are sure the respirator equipment is correctly assembled, is working properly and is properly worn. See Section 3 for information on the auto-darkening helmet assembly. The powered air-purifying respirator (PAPR) filters contaminated air and blows clean air into the welding helmet hood through a flexible breathing hose. The respirator system also generates a positive air pressure to help prevent contaminants from entering the hood. The equipment includes the equipment listed below:

  • Helmet with auto darkening lens, hood and headgear.  Breathing hose  Blower assembly with filtration system (spark guard cover, foam prefilter, HEPA filter) and battery level indicator.  Belt assembly  Air flow speed (Low and High) indicator B a t t e r y c h a r g e r The respirator operates at temperatures from -5 to 55 oC and provides air flow of 170 L/pm (low speed) to 200 L/pm (high speed) - under normal conditions. Battery life is reduced when the unit is used in a dirty environment. If the system air flow decreases to an unsafe level an alarm will sound, the blower vibrates, and the Danger light will flash to warn users to immediately leave the contaminated area. Use the air flowmeter to determine if the unit is supplying adequate amounts of clean air.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com PRODUCT SPECIFICATIONS DARKENING HELMET AIR PURIFYING RESPIRATOR Viewing field (W x H) 100 x 98 mm Shade available in Light State DIN4 Shade available in Dark State DIN 9-13 UV/IR protection Max shade DIN16 at all times Operating temperature range -5 oC - +55oC Weight 400g Switching time from light to dark 1/30,000 second Delay time from dark to light 0.1 - 1.0 second Lens power control Auto-on Power supply Solar Cells / 2 x CR2450 Lithium Batteries Construction material Polyamide (flame retardant) Cartridge Dimensions 180 x 107 x 37mm Weight 1.2kg Standard air filter grade 0.3 micron Air flow Low speed -170LPM High speed -200LPM Operating temperature range -5 oC - +55oC Storage temperature -10oC to 50oC Storage humidity <90% Blower unit shelf life Filter shelf life 1 year 3 years Battery type Rechargable lithium ion Battery charging time Approx 3 hours Battery life 500 charges dependant on airflow rate Run Time Low speed app 6 hrs/High speed 4hrs System alarm 85 dBA@10cm Standard & Class EN12941 Class TH3

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SECTION 1 - SAFETY PRECAUTIONS USING THE HEADSHIELD 1. This headshield is not suitable for la ser welding, laser cutting or overhead welding applications or for oxy-acetylene usage. 2. The lens in this headshield is brea kable and will not protect against impact hazards. 3. This headshield is designed for use in grinding, arc welding or cutting applications such as MIG/MAG, TIG, MMA, Plasma Arc and Carbon Arc. 4. Use this headshield for face and eye protection against harmful rays, sparks and spatter from welding and cutting. 5. NEVER place this product on a hot surface. 6. In the event of failure, the headshield continues to offer protection against UV and IR radiation. 7. DO NOT make any modifications to this product. Protection can be seriously impaired if modifications are made. 8. When necessary, use iden tical replacement parts. This will ensure that the safety of the product is maintained. 9. DO NOT use if any part of the headshield is cracked or broken. 10. DO NOT use this headshield for welding outside the range of DIN 9-13. Harm to the eyes and impaired eyesight may result. ALWA YS select the correct setting before use. USING THE RESPIRATOR 1. If ventilation is poor, ALWAYS wear this respirator. 2. Read and understand the Materi al Safety Data Sheets and the manufacturer's instructions for metals, consumables, coatings, cleaners, and degreasers. 3. Only work in a confined space if it is well ventilated or while wearing the air- supplied respirator. 4. ALWA YS have a trained watch-person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breathing air is safe. 5. DO NOT weld in locations near degreasing, cleaning, or spraying activities. The heat and rays of the arc can react with vapours to form highly toxic and irritating gases.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 6. DO NOT weld on coated metals such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded. 7. Respirator misuse can be hazardous. Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. 8. Read and follow these in structions and the safety labels carefully. The powered air purifying respirator (PAPR) helps protect the user from specific airborne contaminants but must be used correctly to be fully effective. Have an industrial hygienist test the air in your facility to ensure the PAPR provides adequate protection from contaminants in your environment. If you have questions about the respirator, see equipment warning label and consult your Safety Director and a certified Industrial Hygienist. 9. Follow all applicable EN/ANSI/CSA/AS & NZS, and other regulatory guidelines pertaining to the use of respirators. 10. DO NOT use the powered air purifying respirator where there is danger of fire of explosion. 11. DO NOT use the powered air purifying respirator in windy conditions or negative pressure inside the hood may draw in contaminants from the outside air. 12. DO NOT use the powered air purifying respirator without a properly installed spark guard cover. 13. Without the spark guard cover, welding sparks may ignite the filter or damage the filters and allow unfiltered air into the helmet. 14. The powered air purifying respirator does not supply oxygen. Use the respirator only in atmospheres for which it is EN/ANSI/CSA/AS & NZS approved. DO NOT use the respirator where oxygen levels are 19.5% or lower, where contaminant levels are unknown or are immediately dangerous to life or health, or where the contaminant levels exceed the respirator specifications. 15. DO NOT enter a hazardous area until you are sure the respirator equipment is correctly assembled, working properly and properly worn. 16. Before each use, inspect the respirator equipment for damage and verify it operates properly, 17. Before using the respirator, test air flow to verify it is providing an adequate volume of air. 18. DO NOT use the powered air purifying respirator without all filter components or with the blower turned off hazardous levels of oxygen and carbon dioxide may accumulate in helmet.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com 19. ALWA YS wear the powered air purifying respirator when entering a contaminated area. DO NOT remove the respirator until outside the contaminated area. 20. Dangerous contaminants may not smell or be visible. Leave the area immediately if you notice the following:  Breathing becomes difficult.  You experience dizziness, impaired vision, or eye nose, or mouth irritation.  The powered air purifying respirator alarm sounds.  The equipment is damaged.  Air flow decreases or stops.  If you think the equipment is not supplying adequate protection. 21. DO NOT remove the equipment until you are in a safe area. 22. DO NOT repair, modify, or disassemble the powered air purifying respirator or use with parts or accessories not supplied by the manufacturer. Use only those components that are part of the approved assembly. 23. Replace damaged or clogged filters. DO NOT wash or reuse filters. DO NOT clean filters by tapping or with compressed air or filter elements may be damaged. Dispose of used filter elements according to local requirements. 24. The powered air purifying respirator must be used with the helmet, hood, and filters recommended by the manufacturer to provide a respirator system. See the label on the blower for information on the required equipment. 25. DO NOT use the powered air purifying respirator belt or shoulder straps (if equipped) as a safety harness. FURTHER IMPORTANT WARNINGS 1. This product helps protect against certain airborne contaminants 2. DO NOT use in flammable or explosive atmospheres. Doing so may result in serious injury or death. 3. ALWA YS correctly use and maintain the filter assembly. Failure to do so may reduce respirator performance, over-expose you to contaminants, and may result in sickness or death. a. Inspect filter and bottom gasket before first installation of a filter, replace if damaged. b. ALWAYS properly install the filter into the blower unit c. Keep the bottom sealing gasket clean.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com d. NEVER attempt to clean the filter by knocking or blowing out accumulated material. Doing so will damage the filter media. 4. Failure to follow these user instructio ns may reduce respirator performance and expose you to contaminants. 5. Read and follow all user instructions in order to ensure correct system operation. 6. ALWA YS correctly use and maintain the lithium ion battery packs. Failure to do so may cause fire or explosion or could adversely affect respirator performance and result in injury, sickness, or death. a. DO NOT charge batteries with unapproved chargers or in enclosed spaces without ventilation, in hazardous locations, or near sources of high heat. b. Charge in an area free of combustible material and readily monitored. c. DO NOT immerse in water. d. DO NOT use, charge, or store batteries outside the recommended temperature limits. 7. If necessary, dispose of lithium ion batteries according to local environment regulations. Do not crush, disassemble, or dispose of in standard waste bins, in a fire or send for incineration. Failure to properly dispose of battery packs may lead to environmental contamination, fire or explosion. LIMITATIONS OF USE DO NOT wear this respirator system to enter areas where: a. The atmosphere is oxygen deficient b. Contaminant concentrations are unknown c. Contaminant concentrations are immediately dangerous to health. Contaminant concentrations exceed the maximum use concentration determined using the Assigned Protection Factor for the specific respirator system.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SECTION 2 - POWERED AIR PURIFYING RESPIRATOR CHARGING THE BATTERY Remove the battery from the blower assembly and connect the charging cable.Plug the charger into a suitable mains socket. DO NOT allow the battery to get wet. DO NOT attempt to open the battery case. Keep the battery away from fire or heat. Charge the battery before first use. INSTALLING THE BATTERY Push the battery into the blower body until it snaps into position. 1. Battery 2. Battery lock INSTALLING THE AIR FILTER Install the HEPA filter into blower body. Install the foam pre-filter above the HEPA filter. Push down on the cover until it clicks into position. 1. Blower body 2. HEPA filter 3. Foam pre-filter 4. Filter screen 5. Cover DO NOT use the respirator without the foam pre-filter installed. Replace a damaged or dirty filter.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ATTACHING THE BREATHING HOSE Insert the hose connector into the blower receptacle until snug and then turn 1/8 turn to the right to lock it into place. 1. Welding helmet 2. Face seal 3. Headgear terminal 4. Breathing Hose terminal 1 5. Breathing Hose 6. Breathing Hose terminal 2 7. Blower receptacle 8. Belt 9. Blower body Insert the breathing hose terminal into the headgear terminal and turn the hose clockwise until the breathing hose locks in position. TESTING THE AIR FLOW ALARM Disconnect the breathing hose from the hood. Start the blower and block the air flow by placing your hand over the end of the breathing hose. Continue blocking the air flow until the alarm sounds and the blower vibrates. If the alarm does not sound and the blower does not vibrate, check the battery and filter element.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com OPERATING THE CONTROLS 1. Low Speed Indicator 2. High Speed Indicator 3. Danger Indicator 4. Battery Level Indicator 5. Power On/Off Button 6. Low/High, SELECT Button To start, press the On button for 1 second until the blower starts.  The Danger, Low Speed, High Speed Indicator lights come on, then go out, the alarm sounds and the blower vibrates momentarily. The blower always starts at the low speed. Press the SELECT button on the filter casing to switch between Low and High Speeds. To Stop: Press Off button 1 seconds until the audible alarm and blower stop. The Danger indicator light comes on, the alarm sounds and the blower vibrates if battery power is low or air flow is reduced due to a dirty filter, blocked breathing hose or other fault. The Battery Level indicator light shows the power remaining in the battery.  Green light: - battery level > 90%  Yellow light: - 30% battery level < 90%  Red light: -10% battery level < 30%  Red light flash: - battery level < l0%

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com TESTING THE AIR-FLOW Disconnect the breathing hose from the hood. Insert the flowmeter into the breathing hose. Hold the flowmeter straight up and start the blower. The flowmeter ball should be above the MIN mark. If the flowmeter reads MIN or below, check the battery and filter elements. 1. Flowmeter 2. Breathing Tube Connector 3. MIN mark TESTING THE AIRFLOW ALARM Disconnect the breathing hose from the hood. Start the blower and block the air flow by placing your hand over the end of the breathing hose.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com Continue blocking the air flow until the alarm sounds and the blower vibrates. If the alarm does not sound and the blower does not vibrate, check the battery and filter element. CHECKING THE RESPIRATOR BEFORE USE Before using the respirator, check the following items: 1. Verify the air filter is undamaged and securely connected to the blower assembly. 2. Be sure the breathing hose is undamaged and properly connected to the blower assembly and hood. 3. Verify the battery is fully charged and securely connected to the blower assembly. 4. Test the air flow as above. 5. Turn on the blower and check for audible, visual and vibratory airflow alarms. 6. Inspect the face seal and replace if damaged. PUTTING ON THE RESPIRATOR Place the blower assembly against your lower back with the breathing hose extending upwards. Fasten the belt around your waist and adjust so as to make a comfortable fit.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SECTION 3-AUTO-DARKENING WELDING HELMET The Solar-Powered Auto-Darkening Welding Helmet is suitable for most welding and grinding applications. This helmet comes with a 1/30,000-second switching time which automatically darkens the lens the moment you start welding. No matter what shade the filter is set to, the UV/IR protection is always present. CAUTION: ARC RAYS CAN INJURE EYES AND BURN SKIN Before welding, always inspect the helmet and auto-darkening filter (ADF) to be sure they are fitted properly and in good condition. Keep the sensors, solar cell and filter lens clean. Clean the filter cartridge using a soapy water solution and soft cloth. DO NOT use solvents or abrasive cleaning detergent. DO NOT weld in the overhead position while using this helmet. Inspect the filter lens frequently and immediately replace any scratched, cracked or pitted filter lens or cover lenses. ALWAYS wear protective clothing to protect your skin from radiation, burns and welding spatter.

1 Solar Panel 5 Grind/Weld Switch

2 Arc Sensor 6 Delay Control Knob

3 UV/IR Filter 7 Shade number control knob

  1. Sensitivity Control Knob 8 C R2450 Lithium Battery (inside)

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SECTION 4 - PREPARATION & USE USING THE HELMET 1. Remove the protective film from the lens cartridge.  The lens will be set to Light DIN 4 state, & you will be able to see the workpiece. The lens will automatically darken when an arc is struck. 2. Test the lens by striking an arc on the workpiece for the first time. Check also that the outer screen and lens are clean and clear at all times. 3. Change the settings as required using the controls described previously. Refer to the Shade Guide Table on page 17. HEADGEAR ADJUSTMENT 1. Adjust the headband diameter with the twist knob on the back. The knob is locked until pushed in. Once unlocked, twist clockwise to tighten and counterclockwise to loosen. 2. Adjust the height and snap the pin into the hole to lock securely in place. 3. To adjust the viewing angle, loosen the knob on both sides of the helmet and change the angle locker to the desired tilt position (positioned in the middle by default). Once the desire angle is set, tighten the knobs until snug. The helmet should still swing up, but it should not drift downward when in place for welding. 4. To adjust the distance between the user's face and ADF, loosen the knobs on both sides of the helmet until the headband can move back and forth freely, reposition the headband at one of the 3 slots as desired (The headband is positioned in the middle by default). This should be done one side at a time and both sides should be located at the same position for correct auto-darkening filter operation. WARNING: IT IS ESSENTIAL THAT AFTER USING THE HEADSHIELD IN GRINDING MODE, IT SHOULD BE RETURNED TO THE CORRECT SETTING BEFORE WELDING. FAILURE TO DO THIS COULD LEAD TO EYE INJURY.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SCREEN SETTINGS SELECT THE SHADE SETTING WARNING: DO NOT USE FOR WELDING OUTSIDE THE RANGE OF DIN 9-13. INJURY TO THE EYES & LOSS OF EYESIGHT MAY BE CAUSED. On striking an arc, the light created will activate the solar cell and the window will automatically darken to a preset level. The lithium battery will provide the necessary energy to operate the headshield when there is no arc light. You can adjust this shade level using the shade adjustment knob on the side of the headshield, corresponding to the type of welding process.  There are five levels available; 9, 10, 11, 12 and 13. Check the table on page 17 to determine which you should select. 1. Set the shade selector to the required setting. 2. During the welding operation the lens will automatically darken to the pre- set shade. On removal of the arc, the lens will return to the light state. 3. Adjust the ‘Sensitivity’ and ‘Delay’ using the switches on the side of the headshield. SHADE CONTROL Select the shade DIN 9 to 13 based upon the welding process you will use by consulting the “Shade Guide Table”. The variable shade control knob is for internal adjustment. The welding helmet can also be used to protect the face when cutting, from shade DIN 5 to 8. Grind mode DIN 4 prevents filter lens from auto-darkening for grinding use.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SHADE GUIDE TABLE Shade numbers according to BS 379, DIN 4647-1 and EN 169.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SENSITIVITY CONTROL The sensitivity can be set from LOW to HIGH using the dial knob. The LOW setting suits excess ambient light or with another welding machine close by. The HIGH setting suits low amperage welding and welding in areas with low light conditions, especially low amperage argon arc welding. Selections between LOW and HIGH are suitable for most of indoor and outdoor welding. DELAY CONTROL When welding ceases, the viewing window automatically changes from dark back to light but with a pre-set delay to compensate. The delay time can be set from MIN (0.1 sec) to MAX (1.0 sec) using the dial knob. The minimum delay suits spot or short welds. The maximum delay suits heavy current welding and reduces eye fatigue from the arc. Selections between MIN and MAX are suitable for most indoor and outdoor welding operations. SELECT THE GRINDING SETTING The headshield has a ‘Grinding’ setting on the selector panel. When set to ‘Grind’ the auto darkening function is disabled. The headshield then provides eye and face protection for sparks and airborne particles created during grinding activities. DO NOT WELD WITH “GRIND” SELECTED.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com SECTION 5-CARE & MAINTENANCE HELMET CARE & MAINTENANCE Damaged components must be replaced immediately to avoid risk of eye and face injuries. Periodically inspect the filter cartridge and lenses. Cracked, pitted or scratched lenses reduce vision and seriously reduce the level of protection and should be replaced with genuine, certified spare parts. The cartridge can be wiped with a household glass cleaner when dirty. Apply the cleaner with a clean cloth or paper towel. DO NOT USE ALCOHOL TO CLEAN. DO NOT APPLY CLEANER DIRECTLY TO THE CARTRIDGE. Clean all lenses with a soft tissue and suitable lens cleaning fluid. Do not use solvents. NEVER use tools or other sharp objects to remove material from the lens or screen. This may cause damage which may cause incorrect function and invalidate the warranty. Store the unit in it’s box or similar safe place. FRONT COVER LENS REPLACEMENT Replace the front cover lens if it is damaged (cracked, scratched, pitted or dirty). Remove the old front cover lens by pressing two lock switches at the bottom of the retaining frame and pull the frame and ADF out. Take the old front cover lens out, and remove any protective film before installing the new one. INSIDE COVER LENS REPLACEMENT Replace the inside cover lens if it is damaged (cracked, scratched, pitted or dirty). Place your finger or thumb into the recess and flex the inside cover lens upwards until it releases from one edge. Remove any protective film before installing the new one. BATTERY REPLACEMENT When the low voltage indicator turns red, the batteries need replacing. Removing the ADF from the retaining frame. Slide the cover plates on the top left and right and replace the old lithium ion battery. Replace the cover plates of the battery and install the ADF back to the frame. CLEANING AND STORING Keep the sensors, solar cell and filter lens clean. Clean filter cartridge and helmet shell by using a soapy water solution and soft cloth. DO NOT use solvents or abrasive cleaning detergent. Switch the product to Grind Mode and put it in a clean, dry location for storage.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com RESPIRATOR CARE & MAINTENANCE The respirator must be used together with the correct particle filter at all times. The particle filter can not be cleaned. DO NOT attempt to remove contamination using for example, compressed air, as this will destroy the filters, which will not give the expected protection and the warranty will be invalidated. DO NOT store outside the temperature range -5oC to +55oC or in relative humidity greater than 90%. The filter must be kept clean from dust and large particles. NOTE: Markings The particle filters are marked according to EN12941:1998+Al:2003+A2:2008, EU2016/425. TH3P RSL: Class TH3, protection against Particulate, SL = particles of liquid or solid material in aerosol form. FILTER REPLACEMENT Push down on the cover until it clicks into position as shown. Lift the top cover and remove the filter. FILTER INSTALLATION 1. Blower body 2. HEPA Filter 3. Foam prefilter 4. Filter screen 5. Cover Attention: Filter screen and foam pre-filter protects increases the life of the particle filter HFS-2000.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com CLEANING Detach the battery pack and breathing hose from the blower. Inspect all parts for damage and replace any damaged parts prior to storage or next use. a. Blower: Clean the outer surfaces of PAPR assembly and battery pack with a soft cloth dampened in a solution of water and mild, pH neutral detergent. Do not immerse the blower or battery pack in water. DO NOT use solvents or abrasive cleaners. DO NOT attempt to clean the interior of the blower with compressed air or vacuum. Ensure the electrical contacts of the blower and battery pack are dry. b. Breathing hose: Clean the connection sites on the breathing hose with a water and detergent solution. The breathing hose can be immersed in water for cleaning. The inside of the hose must be completely dried prior to use or storage. Air dry, or dry by connecting to the blower unit and use it to force air through the hose until dry. c. HEPA filter: Open the filter cover and inspect the HEPA filter. Replace if excessively dirty. STORAGE If the blower will not be used for a long period, remove the filter and battery and store them in a clean, dry, cool place free of solvent-based vapours. TROUBLESHOOTING Use the table below to help identify possible causes and corrective action for problems you may experience. Fault Possible solution Blower does not supply air to the hood. 1. Press ON to start blower. 2. Recharge battery. 3. Verify battery is correctly connected to the blower. 4. Remove any blockage from blower outlet and breathing hose. 5. Ensure hose is connected correctly. Battery pack charge last less than expected. 1. Ensure battery pack is fully charged. 2. Replace battery. 3. Replace charger. 4. Check the air filter (HEPA and pre-filter) and replace if necessary. Blower cannot be turned off. Press ON/OFF button for one second. Battery RED level light is flashing Charge or replace battery. Danger light is on. alarm sounds or blower vibrates. Check the blower air flow as in Page11.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com ENVIRONMENTAL PROTECTION If broken, DO NOT dispose of this product with general household waste. This product contains valuable raw materials and should be disposed of appropriately at a recognised disposal facility. Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. This means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility. BATTERY DISPOSAL Dispose of old batteries in accordance with local authority regulations. Do not incinerate or crush, as this will increase the risk of explosion and contamination. If the battery contents come into contact with skin or the eyes, rinse with clean water for several minutes and seek medical advice immediately afterwards.

Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com COMPONENT PARTS-HELMET GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights.

1 Helmet shell 6 Height adjusting pin

2 Front cover lens 7 Diameter adjusting knob

3R u b b e r g a s k e t 8A n g l e / d i s tance adjusting knobs 4. ADF 9 Protective plate

5 Retaining frame