N9068A & W9068A Technical Overview
– One-button, easy-to-use, fast phase noise measurements with log plot and spot frequency views – Spectrum and IQ waveform monitoring for quick signal checks in frequency or time domain – Supports the X-Series signal analyzers with external mixing for carrier frequencies beyond 50 GHz – Hardkey/softkey manual user interface or SCPI remote user interface – Built-in, context-sensitive help – Transportable licensing between X-Series signal analyzers or MXE EMI receiver
Figure 1. A complete solution for phase noise measurements
expressed in logarithmic scale. Figure 2. Log plot phase noise with a smoothed trace and decade table measurement accuracy and speed. can be tedious and time consuming. local oscillators and signal sources.
Figure 3. Carrier frequency drift view with phase noise vs. time user-specified number of averages.
1 MHz so that you observe only
- Requires Option AFP or ATP for previ -
Figure 4. Monitor spectrum to check the signal coming from the DUT domain view for a quick signal check. decrease your measurement time. Figure 5. Apply a wide variety of advanced markers and marker functions,
4 Band marker, RMS integrated phase deviation in degree
5 Band marker, RMS integrated phase deviation in radian
6 Band marker, RMS integrated jitter in radian
7 Band marker, RMS integrated phase noise in dBc per marker
8 Band marker, residual FM in Hz
9 Band marker, RMS averaged phase noise density in dBc per Hz
07 | Keysight | Phase Noise X-Series Measurement Application N9068A & W9068A - Technical Overview Integrated noise measurement Different applications require differ - ent measures for evaluating phase noise behaviors. In the digital world, root-mean-square (rms) phase devia - tion/jitter (in degrees or radians) and rms phase jitter (in seconds) are used more frequently to evaluate the sta - bility of a high-frequency clock. On the other hand, residual FM is more important to amplifier designers and manufacturers. The X-Series signal analyzers make these measurements easy with advanced marker functions (Figure 4). The band marker functions enable you to: – Characterize phase noise related behaviors from different angles for various applications – Adjust bandwidth for integrating noise power (in dB/bandwidth Hz) 1 or averaging noise power density (in dB/Hz) 1 by using advanced band markers on the log plot – Calculate rms phase deviation (or residual PM) in degrees or radi - ans – Calculate rms jitter in seconds – Calculate the residual FM in Hz – View numeric marker readings for calculated results – View readings of multiple mark - ers Multiple spurious peak search The marker menu supports the spurious peak search function1, peak, next peak, right peak, and left peak. The “raw” trace (yellow) indicates that spurious signals are automati - cally detected and separated. The “smoothed” trace (light blue) remains after the spurious products are re - moved from the “raw” trace. Advanced scaled delta markers The delta marker menu enables you to select various scales of: – Absolute/normal (x Hz) – Octave slope (2x Hz) 1 – Decade slope (10x Hz)1 1. Requires Option AFP or ATP for previ - ously purchased equipment.
Figure 8. Phase noise measurement at 67 GHz with PXA Option EXM and feature phase noise subtraction.
10 | Keysight | Phase Noise X-Series Measurement Application N9068A & W9068A - Technical Overview Key Specifications Description PXA MXA EXA CXA CXA-m MXE Measurement modes Log plot, spot frequency, spectrum monitor, and IQ waveform Maximum carrier frequency Opt 503: 3.6 GHz Opt 508: 8.4 GHz Opt 513: 13.6 GHz Opt 526: 26.5 GHz Opt 543: 43 GHz Opt 544: 44 GHz Opt 550: 50 GHz Opt EXM: > 50 GHz Opt 503: 3.6 GHz Opt 508: 8.4 GHz Opt 513: 13.6 GHz Opt 526: 26.5 GHz Opt 503: 3.6 GHz Opt 507: 7.0 GHz Opt 513: 13.6 GHz Opt 526: 26.5 GHz Opt 532: 32 GHz1 Opt 544: 44 GHz1 Opt 503: 3.0 GHz Opt 507: 7.5 GHz Opt 513: 13.6 GHz Opt 526: 26.5 GHz Opt F03: 3.0 GHz Opt F07: 7.5 GHz Opt F13: 13.6 GHz Opt F26: 26.5 GHz Opt 508: 8.4 GHz Opt 526: 26.5 GHz Offset frequency range Minimum offset frequency 1 Hz2 Maximum offset frequency (fopt - fcf) Hz, where fopt is the max frequency of the analyzer's frequency option, and fcf the carrier frequency of the signal under test Maximum number of decades Depends on frequency offset range Measurment accuracy Phase noise density ac - curacy Smoothing Fine-adjustable between 0% and 16% rms noise calculation rms phase deviation, rms jitter, residual FM, rms noise power 1, and integrated noise power 1 are calculated over a user-defined integral interval Base instrument phase noise (Typical with center frequency = 1 GHz) Offset frequency 100 Hz 1 kHz 10 kHz 100 kHz
1 MHz
10 MHz
–100 dBc/Hz –125 dBc/Hz –132 dBc/Hz –131 dBc/Hz –146 dBc/Hz –158 dBc/Hz –91 dBc/Hz –112 dBc/Hz (nom) –113 dBc/Hz –116 dBc/Hz –135 dBc/Hz –148 dBc/Hz (nom) –84 dBc/Hz –98 dBc/Hz (nom) –103 dBc/Hz –115 dBc/Hz –135 dBc/Hz –148 dBc/Hz (nom) N.A. –103 dBc/Hz –110 dBc/Hz –110 dBc/Hz –130 dBc/Hz –145 (nom) dBc/Hz – 90 (nom) dBc/Hz –105 dBc/Hz –110 dBc/Hz –110 dBc/Hz –132 dBc/Hz –145 (nom) dBc/Hz 1. Base instrument phase noise performance at 1 GHz for mmW EXA is slightly different from that for RF/uW EXA. Refer to EXA specifications guide for more details. 2. Requires Option AFP or ATP for previously purchased equipment Definitions – Specifications describe the performance of parameters covered by the product warranty. – 95th percentile values indicate the breadth of the population (≈2σ) of performance tolerances expected to be met in 95% of cases with a 95% confidence. These values are not covered by the product warranty. – Typical values are designated with the abbreviation “typ.” These are per - formance beyond specification that 80% of the units exhibit with a 95% confidence. These values are not covered by the product warranty. – Nominal values are designated with the abbreviation “nom.” These values indicate expected performance, or describe product performance that is useful in the application of the product, but is not covered by the product warranty. Note: Data subject to change
13 | Keysight | Phase Noise X-Series Measurement Application N9068A & W9068A - Technical Overview
Ordering Information
Software licensing and configuration Choose from two license types: – Fixed, perpetual license: This allows you to run the application in the X-Series analyzer in which it is initially installed. – Transportable, perpetual license: This allows you to run the application in the X-Series analyzer or controller in which it is initially installed, plus it may be transferred from one X-Series analyzer or controller to another. Try Before You Buy! Free 30-day trials of X-Series measurement applications provide unrestricted use of each applica - tion’s features and functionality on your X-Series analyzer. Redeem a trial license online today: www.keysight.com/find/X-Series_trial The table below contains information on our fixed, perpetual licenses. For more information, please visit the product web pages. N9068A & W9068A phase noise X-Series measurement application Description Model-Option Additional information PXA, MXA, EXA CXA/CXA-m 1 Phase noise N9068A-2FP W9068A-2FP Phase noise feature enhancements N9068A-AFP W9068A-AFP Option AFP is for upgrades only. Enhancements are standard with purchase of new N/W9068A. 1. The CXA-m only supports transportable license. Visit the product web page for further information. www.keysight.com/find/N9068A-MEU www.keysight.com/find/W9068A-MEU
14 | Keysight | Phase Noise X-Series Measurement Application N9068A & W9068A - Technical Overview Hardware configuration N9030A PXA signal analyzer Description Model-Option Additional information frequency range N9030A-503, -508, -513, -526, -543, -544, or -550 One required External mixing N9030A-EXM One required N9020A MXA signal analyzer Description Model-Option Additional information 3.6, 8.4, 13.6, or 26.5 GHz frequency range N9020A-503, -508, -513, or -526 One required N9010A EXA signal analyzer Description Model-Option Additional information 3.6, 7.0, 13.6, 26.5, 32, or 44 GHz frequency range N9010A-503, -507, -513, -526, -532, or -544 One required External mixing N9010A-EXM (only available for frequency range options -532 and -544) One required N9000A CXA signal analyzer Description Model-Option Additional information 3.0, 7.5, 13.6, or 26.5 GHz frequency range N9000A-503, -507, -513, or -526 One required N9038A MXE EMI receiver Description Model-Option Additional information 8.4 or 26.5 GHz N9038A-508, 526 One required M9290A CXA-m PXIe signal analyzer Description Model-Option Additional information 3.0, 7.5, 13.6, or 26.5 GHz frequency range M9290A-F03, -F07, -F13 or -F26 One required For a complete list of specifications refer to the appropriate specifications guide. PXA: www.keysight.com/find/pxa_specifications MXA: www.keysight.com/find/mxa_specifications EXA: www.keysight.com/find/exa_specifications CXA: www.keysight.com/find/cxa_specifications MXE: www.keysight.com/find/mxe_specifications CXA-m: www.keysight.com/find/cxa-m_specifications
15 | Keysight | Phase Noise X-Series Measurement Application N9068A & W9068A - Technical Overview Related Literature N9068A & W9068A phase noise measurement application measurement guide , literature number N9068-90011 Phase Noise Measurement Selection Guide, literature number 5990-5725EN Web Product page: www.keysight.com/find/n9068a www.keysight.com/find/w9068a X-Series measurement applications: www.keysight.com/find/X-Series_Apps X-Series signal analyzers: www.keysight.com/find/X-series MXE EMI receiver: www.keysight.com/find/MXE CXA-m PXIe signal analyzer: www.keysight.com/find/CXA-m
16 | Keysight | Phase Noise X-Series Measurement Application N9068A & W9068A - Technical Overview This information is subject to change without notice. © Keysight Technologies, 2013 - 2015 Published in USA, March 18, 2015 5989-5354EN www.keysight.com myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA ®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-02-20-15)