N9051B KEYSIGHT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 13

Technical content

N9051B Pulse Measurement Software X-Series Signal Analyzers

02 | Keysight | N9051B Pulse Measurement Software X-Series Signal Analyzers - Technical Overview

Features

– Display pulsed signals in a power-vs-time trace, providing more complete insight into radar, EW, and other pulsed signals — from your spectrum analyzer – Measure pulsed carriers up to 50 GHz and bandwidth up to 160 MHz (depending on configuration) – Intuitive “zoom” feature give you a closer examination of fine details within a long acquisition, by simply drawing a box with mouse – Up to 10 markers, including delta-markers, allow easy measurements of power differences and time intervals – Export images, traces, and pulse tables for your presentations, reports, archives, and deeper analysis in Excel – Examine phase and frequency characteristics, such as chirp, hopping, pulse-to- pulse phase, etc. (with Option 3FP) – Extended Analysis (Option 4FP) performs statistical analysis on large data sets (up to 200,000 pulses) accumulated from multiple acquisitions – Capture up to 50 MSa with Option 5FP “Deep Capture” – over 100x greater depth than the N9051A

well as amplitude (signal levels in dBm, Watts, or volts). read out precise timing and amplitude information. Figure 1. View pulsed RF signals in a magnitude-vs-time trace. Use markers and delta-markers to examine amplitude and timing details.

Figure 4. Export table or trace data into Excel for further analysis; or copy/paste screen images for reports or File functions let you capture images (JPG, PNG, etc.) for use in presentations or reports.

“envelope” versus time). To also see phase and frequency information, add Option 3FP. pulse-to-pulse phase stability automatically. Figure 5. Open up a second display and view a phase or frequency trace that is time-aligned to the pulse magnitude trace. Here, a linear FM chirp is easily measured.

Figure 6. A distinct window contains the Extended Analysis features, including statistics, trend, and histogram views of large data-sets. Here is the probability distribution of PRI, showing four distinct modes.

Figure 7. With Option 5FP “Deep Capture”, you can capture up to 50 MSa per acquisition.

09 | Keysight | N9051B Pulse Measurement Software X-Series Signal Analyzers - Technical Overview Software Characteristics Parameter E8267D PSG Frequency Up to 50 GHz. Up to maximum of analyzer HW, less BW/2 Trigger types Free Run, External, RF Burst, Video, or Line Sample interval, time resolution Depends on analysis bandwidth (BW) of hardware Min Sample Interval = 1/(1.25*BW) (e.g. 5 ns for 160 MHz BW) Max Sample Rate = 1/(SampleInterval) = 1.25*BW Min pulse width ~6x SampleInterval Min rise-/fall-time ~3x SampleInterval Capture depth (samples), # of trace points Maximum capture depth (in Samples) is: – 50 MSa with Opt 5FP and hardware configuration to support it – 4 MSa with Opt 5FP and other hardware configurations – 409 kSa without Opt 5FP Min 51 Sa and ≥ 10*SampleInterval Display pixel resolution will limit number of visually distinct points Record length SampleInterval * CaptureLengthSa (e.g., 250 mS for 160 MHz BW and 50 MSa) Pulse detection IEEE-181 method, Absolute Level, Level Relative to Max Max # of pulses 1,050 viewable in Pulse Table 200,000 per acquisition, exportable 200,000 cumulative (multiple acquisitions) in Extended Analysis 4FP Scale Auto, Manual, plus “Zoom” (draw box with mouse), and “Zoom Back” Displays Three: – Upper Display: Magnitude (dBm, W, V), Model (best fit overlay) – Lower Display: Phase (deg, rad), Frequency – Tab/Table: Instrument State Summary, Pulse Table, Simple Statistics Markers 10 (absolute or delta) File save, recall, export State (settings of entire application) Image: Upper Display or Entire Screen, as JPG, PNG, GIF, TIF, or BMP Trace (data): Binary (for save/recall), CSV (export to Excel) Pulse Table (data): CSV (export to Excel) Help Getting Started and User’s Reference available as PDF at run-time

10 | Keysight | N9051B Pulse Measurement Software X-Series Signal Analyzers - Technical Overview Comparing N9051A to N9051B The N9051B is the recommended replacement for the N9051A. The following table summarizes the key differences. N9051A N9051B HW control SW Based on “invisible” copy of 89600 VSA software to control instrument Based on IQ Analyzer mode, a thin/light X-app available on all X-SA free of charge Analyzers supported X-Series signal analyzer, PSA, oscilloscopes, more X-Series signal analyzer Host PC and OS X-Series signal analyzer CPU (Windows XP or 7) or generic ext. PC (Windows XP or 7) X-Series signal analyzer CPU (Windows 7 64-bit) Capture depth Up to 409 kSa Up to 50 MSa (with Option 5FP “Deep Capture”) Trace registers Mag, Phase, Freq, Model plus Six registers capable of: – Max Hold, Min Hold, Average – Addition, Subtraction – Spectrum Mag, Phase, Freq, Model (registers eliminated to conserve memory) Amplitude probability curves PDF, CDF, CCDF n/a Low-phase-distortion filter low overshoot or “ringing”) Bessel Filter n/a Start-up time ~5x faster Measurement cycle time ~2x faster SCPI remote programming n/a n/a

Ordering Information

N9051B pulse measurement software configuration Model-Option Description Notes N9051B-2FP Base magnitude-vs-time – Amplitude- or power-vs-time trace and markers – Automatic amplitude and time parameters N9051B-3FP Phase and frequency – Phase-vs-time trace and markers – Frequency-vs-time trace and markers – Automatic phase and frequency parameters – Chirp, pulse-to-pulse phase, etc. Requires 2FP N9051B-4FP Extended analysis – Trend analysis – Probability distribution (histogram) analysis – “Halt on” feature Requires 2FP N9051B-5FP Deep capture (to 50 MSa) – Extended capture depth Requires 2FP See also HW configuration below The table above contains information on “Fixed, Perpetual” (nFP) licenses; these allow you to run the N9051B application in the single X-Series analyzer in which it si initially installed. N9051B licenses are also available in type “Transportable, Perpetual” (nTP); these licenses can be transferred from one X-Series analyzer to another.

11 | Keysight | N9051B Pulse Measurement Software X-Series Signal Analyzers - Technical Overview Hardware configuration Please see “Software characteristics” to understand how bandwidth is related to sample interval, time resolution, rise-/fall-time, and minimum pulse width. Upgrade existing N9051A to N9051B Model-Option Description Notes N9051B-A2B Upgrade N9051A to N9051B Requires N9051A-2FP license N9030A PXA signal analyzer Description Model-Option Additional information frequency range One required 25, 40, 85, or 160 MHz bandwidth N9030A-B25, -B40, -B85, or –B1X One required for analysis bandwidth over 10 MHz (standard) Microwave pre-selector by-pass N9030A-MPB Required for B40 and above, when input is > 3.6 GHz Windows 7 (embedded standard) operating system N9030A-W7X Required All PXA configurations support N9051B-5FP “Deep Capture” to 50 MSa N9020A MXA signal analyzer Description Model-Option Additional information frequency range N9020A-503, -508, -513, or -526 One required 25, 40, 85, 125, or 160 MHz bandwidth or –B1X One required for analysis bandwidth over 10 MHz; on new orders, B25 included at no charge Microwave pre-selector by-pass N9020A-MPB Required for B40 and above, when input is > 3.6 GHz Digital processor with 2 GB capture memory N9020A-DP2 Required for N9051B-5FP “Deep Capture” to 50 MSa if bandwidth option is less than 40 MHz Windows 7 (embedded standard) operating system N9020A-W7X Required Provides –A2B license, which enables N9051B software to recognize ‘A’ licenses when redeemed/installed on the same instrument. N9051A-2FP license is required; -3FP or -4FP licenses will also enable comparable features in N9051B software when combined with –A2B.

12 | Keysight | N9051B Pulse Measurement Software X-Series Signal Analyzers - Technical Overview Additional Information Websites X-Series signal analyzers: www.keysight.com/find/x-series X-Series measurement applications: www.keysight.com/find/x-series_apps N9051B pulse measurement software: www.keysight.com/find/n9051b N9010A EXA signal analyzer Description Model-Option Additional information frequency range One required 25 or 40 MHz bandwidth N9010A-B25, -B40 One required for analysis bandwidth over 10 MHz; on new orders, B25 included at no charge Microwave pre-selector by-pass N9010A-MPB Required with B40, when input is > 3.6 GHz Digital processor with 2 GB capture memory N9010A-DP2 Required for N9051B-5FP “Deep Capture” to 50 MSa if bandwidth option is less than 40 MHz Windows 7 (embedded standard) operating system N9010A-W7X Required N9000A CXA signal analyzer Description Model-Option Additional information 3.0, 7.5, 13.6, or 26.5 GHz frequency range N9000A-503, -507, -513, or -526 One required

25 MHz bandwidth N9000A-B25 Required for analysis bandwidth over 10 MHz (standard)

Windows 7 (embedded standard) operating system N9000A-W7X Required All CXA configurations limit N9501B-5FP “Deep Capture” to only 4 MSa Instrument must have 64-bit CPU and Windows 7 operating system. Currently shipping products (new orders) meet these criteria. Previously shipped instruments should be verified, and (if necessary) upgraded prior to installing N9051B. For details, visit www. keysight.com , then search for model number (e.g. N9030A), then click on “Post- Purchase Upgrades” link (under “Product Support Center” on right), then find PC4, PC5, or W7X

13 | Keysight | N9051B Pulse Measurement Software X-Series Signal Analyzers - Technical Overview This information is subject to change without notice. © Keysight Technologies, 2014 Published in USA, October 30, 2014 5992-0233EN www.keysight.com myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG, Inc, U.S.A. and licensed to Keysight Technologies, Inc. www.keysight.com/find/n9051b For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-10-14)