N9038A KEYSIGHT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 24

Technical content

3 Hz to 3.6, 8.4, 26.5, and 44 GHz Data Sheet

In EMC testing, success depends on tools that can help you do more in less time—today and tomorrow. That’s why Keysight Technolo - gies, Inc. created the MXE: it’s a standards-compliant EMI receiver and diagnostic signal analyzer built on an upgradeable platform. In the lab and on the bench, it provides the accuracy, repeatabil - ity, and reliability you need to test with confidence. Equip your team with the MXE, and keep the test queue flowing. 02 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Definitions and Conditions Specifications describe the performance of parameters covered by the product warranty and apply to the full temperature range of 0 to 55 °C, unless otherwise noted. 95th percentile values indicate the breadth of the population (approx. 2 σ) of performance tolerances expected to be met in 95 percent of the cases with a 95 percent confidence, for any ambient temperature in the range of 20 to 30 °C. In addition to the statistical observations of a sample of instruments, these values include the effects of the uncertainties of external calibration references. These values are not warranted. These values are updated occasionally if a significant change in the statistically observed behavior of production instruments is observed. Typical describes additional product performance information that is not cov - ered by the product warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level over the tem - perature range 20 to 30 °C. Typical performance does not include measurement uncertainty. Nominal values indicate expected performance, or describe product perfor - mance that is useful in the application of the product, but are not covered by the product warranty. The receiver will meet its specifications when: – It is within its calibration cycle – Under auto couple control, except when Auto Sweep Time Rules = Accy – Signal frequencies < 10 MHz, with DC coupling applied – The receiver has been stored at an ambient temperature within the allowed operating range for at least two hours before being turned on – The receiver has been turned on at least 30 minutes with Auto Align set to normal, or, if Auto Align is set to off or partial, alignments must have been run recently enough to prevent an Alert message; if the Alert condition is changed from “Time and Temperature” to one of the disabled duration choices, the receiver may fail to meet specifications without informing the user This data sheet is a summary of the specifications and conditions for the MXE EMI receiver. For the complete specifications guide, visit: www.keysight.com/find/mxe_specifications Get more information This data sheet is a summary of the specifications and conditions which are available in the MXE EMI Receiver Specification Guide (N9038-90010). For ordering information, refer to the MXE EMI Receiver Configura - tion Guide (5990-7419EN). 03 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Frequency and Time Specifications Frequency range DC coupled AC coupled Input 1 Option 503 Option 508 Option 526 Option 544 3 Hz to 3.6 GHz 3 Hz to 8.4 GHz 3 Hz to 26.5 GHz

3 Hz to 44 GHz

10 MHz to 3.6 GHz 10 MHz to 8.4 GHz 10 MHz to 26.5 GHz Input 2 3 Hz to 1 GHz 10 MHz to 1 GHz Band LO multiple (N) 0 1 3 Hz to 3.6 GHz 1 1 3.5 to 8.4 GHz 2 2 8.3 to 13.6 GHz 3 2 13.5 to 17.1 GHz 4 4 17.0 to 26.5 GHz 5 4 26.4 to 34.5 GHz 6 8 34.4 to 44 GHz Frequency reference Accuracy ± [(time since last adjustment x aging rate) + temperature stability + calibration accuracy] Total aging ± 1 x 10–7 / year ± 1.5 x 10–7 / 2 years Temperature stability 20 to 30 °C Full temperature range ± 1.5 x 10–8 ± 5 x 10–8 Achievable initial calibration accuracy ± 4 x 10–8 Residual FM ≤ (0.25 Hz x N) p-p in 20 ms (nominal) Frequency readout accuracy (start, stop, center, marker) ± (marker frequency x frequency reference accuracy + 0.25 % x span + 5 % x RBW + 2 Hz + 0.5 x horizontal resolution 1) Marker frequency counter Accuracy ± (marker frequency x frequency reference accuracy + 0.100 Hz) Delta counter accuracy ± (delta frequency x frequency reference accuracy + 0.141 Hz) Counter resolution 0.001 Hz Frequency span (FFT and swept mode) Range 0 Hz (zero span), 10 Hz to maximum frequency of instrument Resolution 2 Hz Accuracy Stepped/Swept FFT ± (0.25 % x span + horizontal resolution) ± (0.1% x span + horizontal resolution) 1. Horizontal resolution is span/(sweep points – 1). 04 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Range Span = 0 Hz Span ≥ 10 Hz 1 μs to 6000 s 1 ms to 4000 s Accuracy Span ≥ 10 Hz, swept Span ≥ 10 Hz, FFT Span = 0 Hz ± 0.01 % (nominal) ± 40 % (nominal) ± 0.01 % (nominal) Trigger Free run, line, video, external 1, external 2, RF burst, periodic timer Trigger delay Span = 0 Hz or FFT Span ≥ 10 Hz, swept Resolution –150 to +500 ms 0 μs to 500 ms 0.1 μs Time gating Gate methods Gated LO; gated video; gated FFT Gate length range (except method = FFT) 100.0 ns to 5.0 s Gate delay range 0 to 100.0 s Gate delay jitter 33.3 ns p-p (nominal) Sweep (trace) point range All spans 1 to 4,000,001 Resolution bandwidth (RBW) EMI bandwidths (CISPR compliant) 200 Hz, 9 KHz, 120 kHz, 1 MHz EMI bandwidths (Mil STD 461 compliant) 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz Range (–3.01 dB bandwidth) 1 Hz to 3 MHz (10 % steps, E24 series, 24 per decade), 4, 5, 6, 8 MHz Bandwidth accuracy (power) 1 Hz to 750 kHz 820 kHz to 1.2 MHz (< 3.6 GHz CF) 1.3 to 2 MHz (< 3.6 GHz CF) 2.2 to 3 MHz (< 3.6 GHz CF) 4 to 8 MHz (< 3.6 GHz CF) ± 0.07 dB (nominal) ± 0.15 dB (nominal) ± 0.25 dB (nominal) Bandwidth accuracy (–3.01 dB) 1 Hz to 1.3 MHz ± 2 % (nominal) Selectivity (–60 dB/–3 dB) 4.1:1 (nominal) RF preselector filters Filter band Filter type 6 dB BW (nominal)

20 Hz to 150 kHz

600 MHz to 1 GHz

2 to 3.6 GHz Fixed lowpass Fixed bandpass Fixed bandpass Fixed bandpass Fixed bandpass Fixed bandpass Fixed bandpass Fixed bandpass Fixed bandpass Fixed bandpass Fixed bandpass Tracking bandpass Tracking bandpass Tracking bandpass Tracking bandpass Tracking bandpass Tracking bandpass Fixed highpass 310 kHz

1.7 MHz

2.4 MHz

7.5 MHz

10 MHz

9.5 MHz

9.0 MHz

24 MHz

28 MHz

50 MHz

60 MHz

180 MHz

1.89 GHz

(–3 dB corner frequency) 05 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Maximum bandwidth Option B25 Standard

25 MHz

Video bandwidth (VBW) Range 1 Hz to 3 MHz (10 % steps, E24 series 24 per decade), 4, 5, 6, 8 MHz, and wide open (labeled 50 MHz) Accuracy ± 6 % (nominal) Measurement speed 2 Standard Local measurement and display update rate 4 ms (250/s) (nominal) Remote measurement and LAN transfer rate 5 ms (200/s) (nominal) Marker peak search 1.5 ms (nominal) Center frequency tune and transfer (RF) 20 ms (nominal) Center frequency tune and transfer (μW) 47 ms (nominal) Measurement/mode switching 39 ms (nominal) Time domain sweep times CISPR band B, 150 kHz to 30 MHz, RBW = 9 kHz, measurement time = 100 ms, peak detector 11.4 s (nominal) CISPR band B, 150 kHz to 30 MHz, RBW = 9 kHz, measurement time = 1 s, quasi-peak detector 181.4 s (nominal) CISPR band C/D, 30 MHz to 1 GHz, RBW = 120 kHz, measurement time = 10 ms, peak detector 2.1 s (nominal) CISPR band C/D, 30 MHz to 1 GHz, RBW = 9 kHz, measurement time = 10 ms, peak detector 12.6 s (nominal) CISPR band C/D, 30 MHz to 1 GHz, RBW = 120 kHz, measurement time = 1 s, quasi-peak detector 210.9 s (nominal) 1. Analysis bandwidth is the instantaneous bandwidth available around a center frequency over which the input signal can be digitized for further analysis or processing in the time, frequency, or modulation domain. 2. Sweep points = 101. 06 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Amplitude Accuracy and Range Specifications Amplitude range Measurement range Displayed average noise level (DANL) to maximum safe input level Input attenuator range 0 to 70 dB in 2 dB steps Maximum safe input level (with and without preamp) RF Input 1 RF Input 2 Average total power +30 dBm (1 W) +30 dBm (1 W) Peak pulse power +45 dBm (31.6 W) +50 dBm (100 W) < 10 μs pulse width, < 1 % duty cycle and input attenuation ≥ 30 dB Surge power +2k W (10 μs pulse width) DC volts DC coupled AC coupled ± 0.2 Vdc ± 100 Vdc ± 0.2 Vdc ± 100 Vdc Display range Log scale 0.1 to 1 dB/division in 0.1 dB steps 1 to 20 dB/division in 1 dB steps (10 display divisions) Linear scale 10 divisions Scale units dBm, dBmV, dBμV, dBmA, dBμA, V, W, A dBuV/m, dBuA/m, dBpT, dBG, dBpW Frequency response Specification 95th percentile (≈ 2σ) Option 503, 508, or 526 (RF/μW) Option 544 (mmW) Option 503, 508, or 526 (RF/μW) Option 544 (mmW) (10 dB input attenuation, 20 to 30 °C, preselector centering applied, σ = nominal standard deviation) RF preselector off, preamp off

3 Hz to 20 Hz

20 Hz to 10 MHz 1

50 MHz to 3.6 GHz 3.5 to 5.2 GHz 5.2 to 8.4 GHz 8.3 to 13.6 GHz 13.5 to 17.1 GHz 17 to 18 GHz 18 to 22 GHz 22 to 26.5 GHz 26.4 to 34.5 GHz 34.4 to 44 GHz ± 0.6 dB ± 0.65 dB ± 0.65 dB ± 1.5 dB ± 1.5 dB ± 1.5 dB ± 1.5 dB ± 1.5 dB ± 1.7 dB ± 1.7 dB ± 0.6 dB ± 0.65 dB ± 0.65 dB ± 1.6 dB ± 1.5 dB ± 1.5 dB ± 1.5 dB ± 1.7 dB ± 1.7 dB ± 1.7 dB ± 2.5 dB ± 3.2 dB ± 0.25 dB (nominal) ± 0.22 dB ± 0.22 dB ± 0.22 dB ± 0.47 dB ± 0.47 dB ± 0.46 dB ± 0.53 dB ± 0.57 dB ± 0.64 dB ± 0.61 dB ± 0.25 dB (nominal) ± 0.25 dB ± 0.21 dB ± 0.15 dB ± 0.6 dB ± 0.57 dB ± 0.54 dB ± 0.64 dB ± 0.72 dB ± 0.72 dB ± 0.71 dB ± 0.93 dB ± 1.24 dB RF preselector off, preamp on (0 dB attenuation) 100 kHz to 3.6 GHz 1 100 kHz to 10 MHz 10 to 50 MHz 50 MHz to 3.6 GHz 3.5 to 8.4 GHz 3.5 to 5.2 GHz 5.2 to 8.4 GHz 8.3 to 13.6 GHz 13.5 to 17.1 GHz 17 to 18 GHz 18 to 22 GHz 17 to 22 GHz 22 to 26.5 GHz 26.4 to 34.5 GHz 34.4 to 44 GHz ± 0.75 dB ± 1.85 dB ± 1.95 dB ± 1.8 dB ± 2.0 dB ± 2.85 dB ± 2.6 dB ± 0.75 dB ± 0.75 dB ± 0.75 dB ± 2.2 dB ± 1.85 dB ± 1.95 dB ± 1.8 dB ± 2.85 dB ± 2.6 dB ± 3.0 dB ± 4.1 dB ± 0.29 dB ± 0.63 dB ± 0.64 dB ± 0.81 dB ± 0.95 dB ± 1.23 dB ± 1.37 dB ± 0.43 dB ± 0.29 dB ± 0.31 dB ± 0.9 dB ± 0.7 dB ± 0.79 dB ± 0.88 dB ± 1.07 dB ± 1.03 dB ± 1.35 dB ± 1.69 dB 1. DC coupling required to meet specifications below 50 MHz. With AC coupling, specifications apply at frequencies of 50 MHz and higher. Statistical observations at 10 MHz with AC coupling show that most instruments meet the DC-coupled specifications, however, a small percentage of instruments are expected to have errors exceeding 0.5 dB at 10 MHz at the temperature extreme. The effect at 20 to 50 MHz is negligible but not warranted. 07 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Frequency response (continued) Specification 95th percentile (≈ 2 σ) Option 503, 508, or 526 (RF/μW) Option 544 (mmW) Option 503, 508, or 526 (RF/μW) Option 544 (mmW) RF preselector on, preamp off

20 Hz to 300 MHz 1

300 MHz to 1 GHz

1 to 3.6 GHz 3.5 to 8.4 GHz 3.5 to 5.2 GHz 5.2 to 8.4 GHz 8.3 to 13.6 GHz 13.5 to 17.1 GHz 17 to 18 GHz 18 to 22 GHz 22 to 26.5 GHz 26.4 to 34.5 GHz 34.4 to 44 GHz ± 0.65 dB ± 0.65 dB ± 0.85 dB ± 1.5 dB ± 1.5 dB ± 1.5 dB ± 1.5 dB ± 1.7 dB ± 1.7 dB ± 0.65 dB ± 0.65 dB ± 0.85 dB ± 1.6 dB ± 1.5 dB ± 1.5 dB ± 1.5 dB ± 1.7 dB ± 1.7 dB ± 1.7 dB ± 2.5 dB ± 3.2 dB ± 0.3 dB (nominal) ± 0.30 dB ± 0.28 dB ± 0.36 dB ± 0.47 dB ± 0.46 dB ± 0.53 dB ± 0.57 dB ± 0.64 dB ± 0.61 dB ± 0.3 dB (nominal) ± 0.3 dB ± 0.28 dB ± 0.36 dB ± 0.6 dB ± 0.57 dB ± 0.54 dB ± 0.64 dB ± 0.72 dB ± 0.72 dB ± 0.71 dB ± 0.93 dB ± 1.24 dB RF preselector on, preamp on (0 dB attenuation) 1 kHz to 30 MHz 1 30 to 300 MHz 1 1 to 2.75 GHz 2.75 to 3.6 GHz 3.5 to 8.4 GHz 3.5 to 5.2 GHz 5.2 to 8.4 GHz 8.3 to 13.6 GHz 13.5 to 17.1 GHz 17 to 18 GHz 18 to 22 GHz 22 to 26.5 GHz 26.4 to 34.5 GHz 34.4 to 44 GHz ± 0.8 dB ± 0.7 dB ± 0.65 dB ± 0.95 dB ± 1.15 dB ± 1.85 dB ± 1.95 dB ± 1.8 dB ± 2.0 dB ± 2.85 dB ± 2.6 dB ± 0.8 dB ± 0.70 dB ± 0.65 dB ± 0.95 dB ± 1.15 dB ± 2.2 dB ± 1.85 dB ± 1.95 dB ± 1.8 dB ± 2.85 dB ± 2.85 dB ± 2.6 dB ± 3.0 dB ± 4.1 dB ± 0.36 dB ± 0.29 dB ± 0.30 dB ± 0.45 dB ± 0.55 dB ± 0.63 dB ± 0.64 dB ± 0.81 dB ± 0.95 dB ± 1.23 dB ± 1.37 dB ± 0.36 dB ± 0.29 dB ± 0.30 dB ± 0.45 dB ± 0.55 dB ± 0.9 dB ± 0.7 dB ± 0.79 dB ± 0.88 dB ± 1.07 dB ± 1.07 dB ± 1.03 dB ± 1.35 dB ± 1.69 dB 1. DC coupling required to meet specifications below 50 MHz. With AC coupling, specifications apply at frequencies of 50 MHz and higher. Statistical observations at 10 MHz with AC coupling show that most instruments meet the DC-coupled specifications, however, a small percentage of instru- ments are expected to have errors exceeding 0.5 dB at 10 MHz at the temperature extreme. The effect at 20 to 50 MHz is negligible but not warranted. Input attenuation switching uncertainty Specifications Attenuation > 2 dB , preamp off Relative to 10 dB (reference setting) (reference frequency) ± 0.20 dB ± 0.08 dB (typical) Absolute amplitude accuracy Specifications 95th percentile (≈ 2σ) (10 dB attenuation, 20 to 30 °C, 1 Hz ≤ RBW ≤ 1 MHz, input signal –10 to –50 dBm, all settings auto-coupled except Auto Swp Time = Accy, any reference level, any scale, σ = nominal standard deviation) RF preselector off and on, preamp off and on RF input 1 to 44 GHz At 50 MHz At all frequencies ± 0.33 dB ± (0.33 dB + frequency response) ± 0.25 dB RF input 2 to 1 GHz At 50 MHz At all frequencies ± 0.36 dB ± (0.36 dB + frequency response) ± 0.27 dB 08 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Input voltage standing wave ratio (VSWR) Input attenuation 0 dB Input attenuation ≥ 10 dB RF preselector off, preamp on and off DC coupled 1 to 18 GHz 18 to 26.5 GHz 26.5 to 40 GHz 40 to 44 GHz 3.0:1 3.0:1 3.0:1 2.0:1 2.0:1 2.5:1 AC coupled 1 to 18 GHz 18 to 26.5 GHz 3.0:1 3.0:1 2.0:1 2.4:1 RF preselector on, preamp on and off DC coupled 9 kHz to 1 GHz 1 to 26.5 GHz 26.5 to 40 GHz 40 to 44 GHz 2.0:1 3.0:1 3.0:1 1.2:1 2.0:1 2.5:1 AC coupled 50 MHz to 1 GHz 1 to 18 GHz 18 to 26.5 GHz 2.0:1 3.0:1 3.0:1 1.2:1 2.0:1 2.4:1 Resolution bandwidth switching uncertainty (referenced to 30 kHz RBW) 1 Hz to 1.5 MHz RBW ± 0.05 dB 1.6 to 3 MHz RBW ± 0.10 dB 4, 5, 6, 8 MHz RBW ± 1.0 dB Reference level Range Log scale –170 to +30 dBm in 0.01 dB steps Linear scale Same as log (707 pV to 7.07 V) Accuracy 0 dB Display scale switching uncertainty Switching between linear and log 0 dB Log scale/div switching 0 dB Display scale fidelity Between –10 dBm and –80 dBm input mixer level ± 0.10 dB total Total measurement uncertainty 1 95th percentile (≈ 2σ) Signal level 0 to 90 dB below reference point, RF attenuation 0 to 40 dB, RBW ≤ 3 MHz, 20º to 30º C: AC coupled 10 MHz to 26.5 GHz DC coupled 9 kHz to 40 GHz Option 503, 508, or 526 (RF/μW) Option 544 (mmW) RF preselector off, preamp off 1 kHz to 2 GHz 2 to 3.6 GHz 3.6 to 8 GHz 8 to 18 GHz 18 to 26.5 GHz 26.5 to 40 GHz 40 to 44 GHz ± 0.50 dB ± 0.60 dB ± 0.80 dB ± 1.10 dB ± 1.60 dB ± 0.50 dB ± 0.60 dB ± 1.70 dB ± 1.30 dB ± 1.60 dB ± 1.70 dB ± 2.30 dB RF preselector off, preamp on 100 kHz to 2 GHz 2 to 3.6 GHz 3.6 to 8 GHz 8 to 18 GHz 18 to 26.5 GHz 26.5 to 40 GHz 40 to 44 GHz ± 0.60 dB ± 0.60 dB ± 1.10 dB ± 1.30 dB ± 1.90 dB ± 0.60 dB ± 0.60 dB ± 1.80 dB ± 1.30 dB ± 1.90 dB ± 1.90 dB ± 2.40 dB 1. Specified for instruments with prefixes MY/SG5322 or greater. 09 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Total measurement uncertainty 1 (continued) 95th percentile (≈ 2σ) RF preselector on, preamp off 9 kHz to 2 GHz 2 to 3.6 GHz 3.6 to 8 GHz 8 to 18 GHz 18 to 26.5 GHz 26.5 to 40 GHz 40 to 44 GHz ± 0.50 dB ± 0.50 dB ± 0.80 dB ± 1.10 dB ± 1.60 dB ± 0.50 dB ± 0.50 dB ± 1.70 dB ± 1.30 dB ± 1.60 dB ± 1.70 dB ± 2.30 dB RF preselector on, preamp on 9 kHz to 2 GHz 2 to 3.6 GHz 3.6 to 8 GHz 8 to 18 GHz 18 to 26.5 GHz 26.5 to 40 GHz 40 to 44 GHz ± 0.50 dB ± 0.70 dB ± 1.10 dB ± 1.30 dB ± 1.90 dB ± 0.50 dB ± 0.70 dB ± 1.80 dB ± 1.30 dB ± 1.90 dB ± 1.90 dB ± 2.40 dB Trace detectors Normal, peak, sample, negative peak, log power average, RMS average, and voltage average CISPR detectors: quasi-peak, EMI-avg, RMS-avg Preamplifier Gain RF preselector off 100 kHz to 3.6 GHz 3.6 to 26.5 GHz 26.5 to 44 GHz +20 dB (nominal) +35 dB (nominal) +40 dB (nominal) RF preselector on 9 kHz to 3.6 GHz 3.6 to 26.5 GHz 26.5 to 44 GHz +20 dB (nominal) +35 dB (nominal) +40 dB (nominal) Amplitude probability distribution Meets CISPR16-1-1:2010 requirements Dynamic range > 70 dB Amplitude accuracy < ± 2.7 dB Maximum measureable time period (no dead time) 2 minutes Minimum measureable probability 10–7 Amplitude level assignment 1000 levels Sampling rate ≥ 10 MSa/s (within a 1 MHz RBW) Amplitude resolution 0.1881 dB 1. Specified for instruments with prefixes MY/SG5322 or greater. 10 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Dynamic Range Specifications 1 dB gain compression Specification Typical Maximum power at mixer Frequency range Option 503, 508, or 526 (RF/μW) Option 544 (mmW) Option 503, 508, or 526 (RF/μW) Option 544 (mmW) RF Input 1 to 44 GHz (RF Input 2 to 1 GHz, performance = RF Input 1 performance + 9 dB) RF preselector on and off, preamp off 9 kHz to 10 MHz +4 dBm (nominal) +4 dBm (nominal) 10 to 500 MHz 0 dBm 0 dBm +3 dBm (typical) +3 dBm (typical) 500 MHz to 3.6 GHz +1 dBm +1 dBm +5 dBm (typical) +5 dBm (typical) 3.6 to 26.5 GHz 0 dBm 0 dBm +4 dBm (typical) +4 dBm (typical) 26.4 to 44 GHz –1 dBm +2 dBm (nominal) RF preselector off, preamp on 10 MHz to 3.6 GHz –13 dBm (nominal) −13 dBm (nominal) 3.6 to 26.5 GHz Tone spacing 100 kHz to 20 MHz −26 dBm (nominal) −30 dBm (nominal) Tone spacing > 70 MHz −16 dBm (nominal) −16 dBm (nominal) 26.4 to 44 GHz −30 dBm (nominal) RF preselector on, preamp on 9 kHz to 10 MHz –16 dBm (nominal) –16 dBm (nominal) 10 to 2 GHz –18 dBm (typical) –21 dBm (typical) 2 GHz to 3.6 GHz –16 dBm (typical) –17 dBm (typical) 3.6 to 26.5 GHz Tone spacing, 100 kHz to 20 MHz −26 dBm (nominal) −30 dBm (nominal) Tone spacing > 70 MHz −16 dBm (nominal) −16 dBm (nominal) 26.4 to 44 GHz −30 dBm (nominal) Displayed average noise level (DANL) (Input terminated, sample or average detector, averaging type = Log, 0 dB input attenuation, IF Gain = High, 20 to 30 °C) RF Input 1; RF Input 2 to 1 GHz; RF Input 2 performance = RF Input 1 performance +11 dB Specification Typical including NFE 1 RF preselector off, preamp off

3 Hz to 10 Hz

20 Hz 2

100 Hz 2

1 MHz

10 MHz to 2.1 GHz 2.1 to 3.6 GHz 3.5 to 8.4 GHz Option 544 8.3 to 13.6 GHz Option 544 13.5 to 17.1 GHz 17.0 to 20.0 GHz 20.0 to 26.5 GHz 26.4 to 34.5 GHz 34.4 to 44 GHz –97 dBm –106 dBm –118 dBm –119 dBm –131 dBm –150 dBm –150 dBm –148 dBm –148 dBm –145 dBm –147 dBm –147 dBm –141 dBm –142 dBm –135 dBm –141 dBm –135 dBm –97 dBm (nominal) 3 –158 dBm –157 dBm –159 dBm –153 dBm –158 dBm –156 dBm –151 dBm –152 dBm –146 dBm –148 dBm –143 dBm RF preselector off, preamp on 100 kHz 10 MHz to 2.1 GHz 2.1 to 3.6 GHz 3.5 to 8.4 GHz Option 544 8.3 to 13.6 GHz Option 544 13.5 to 17.1 GHz 17.0 to 20.0 GHz 20.0 to 26.5 GHz 26.4 to 34.5 GHz 34.4 to 44 GHz –144 dBm –162 dBm –163 dBm –161 dBm –164 dBm –161 dBm –162 dBm –161 dBm –160 dBm –158 dBm –155 dBm –156 dBm –150 dBm –175 dBm –173 dBm –172 dBm –166 dBm –173 dBm –170 dBm –171 dBm –165 dBm –162 dBm –164 dBm –158 dBm 1. Typical Indicated Noise including NFE = typical DANL+ Bandwidth and Log corrrections-DANL improvement with NFE 2. Specified for instruments with prefixes MY/SG5213 or greater. Nominal for instruments with earlier prefixes. 3. No NFE at this frequency. 11 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Displayed average noise level (DANL) (continued) (Input terminated, sample or average detector, averaging type = Log, 0 dB input attenuation, IF Gain = High, 20 to 30 °C) RF Input 1; RF Input 2 to 1 GHz; RF Input 2 performance = RF Input 1 performance +11 dB Specification Typical including NFE 1 RF preselector on, preamp off 3 to 10 Hz

20 Hz 3

100 Hz 3

2 to 2.5 GHz 2.5 to 3 GHz 3 to 3.6 GHz 3.5 to 8.4 GHz Option 544 8.3 to 13.6 GHz Option 544 13.5 to 17.1 GHz 17.0 to 20.0 GHz 20.0 to 26.5 GHz 26.4 to 34.5 GHz 34.4 to 44 GHz –92 dBm –101 dBm –114 dBm –118 dBm –130 dBm –147 dBm –150 dBm –151 dBm –153 dBm –151 dBm –150 dBm –152 dBm –151 dBm –148 dBm –148 dBm –145 dBm –147 dBm –147 dBm –141 dBm –142 dBm –135 dBm –141 dBm –135 dBm –92 dBm (nominal) 2 –100 dBm 2 –109 dBm 2 –120 dBm 2 –132 dBm –143 dBm –158 dBm –160 dBm –161 dBm –164 dBm –162 dBm –161 dBm –164 dBm –163 dBm –161 dBm –159 dBm –153 dBm –158 dBm –156 dBm –151 dBm –152 dBm –146 dBm –148 dBm –143 dBm RF preselector on, preamp on 1 kHz 3 9 kHz 100 kHz 1 to 2 MHz 2 to 30 MHz 30 to 600 MHz 600 to 800 MHz

800 MHz to 1 GHz

2 to 2.75 GHz 2.75 to 3.6 GHz 3.5 to 8.4 GHz Option 544 8.3 to 13.6 GHz Option 544 13.5 to 17.1 GHz 17.0 to 20.0 GHz 20.0 to 26.5 GHz 26.4 to 34.5 GHz 34.4 to 44 GHz –119 dBm –143 dBm –154 dBm –166 dBm –158 dBm –159 dBm –157 dBm –158 dBm –156 dBm –160 dBm –157 dBm –164 dBm –161 dBm –162 dBm –161 dBm –160 dBm –158 dBm –155 dBm –156 dBm –150 dBm –133 dBm2 –154 dBm –165 dBm –178 dBm –167 dBm –166 dBm –166 dBm –167 dBm –164 dBm –168 dBm –165 dBm –172 dBm –166 dBm –173 dBm –170 dBm –171 dBm –165 dBm –162 dBm –164 dBm –158 dBm 1. Typical DANL including NFE = Typical DANL-DANL improvement with NFE. 2. No NFE factor at this frequency. 3. Specified for instruments with prefixes MY/SG5213 or greater. Nominal for instruments with earlier prefixes. 12 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Indicated noise in CISPR BW Calculated from DANL data; EMI-AVG detector, 0 dB input attenuation; indicated RBW is CISPR RBW RF Input 1; RF Input 2 to 1 GHz; RF Input 2 performance = RF Input 1 performance +11 dB Typical including NFE 1 RF preselector on, preamp off 3 to 10 Hz (1 Hz RBW) 3

20 Hz (1 Hz) 3

100 Hz (10 Hz) 3

1 kHz (100 Hz) 3 9 kHz (200 Hz) 100 kHz (200 Hz) 1 to 3 MHz (9 kHz) 3 to 30 MHz (9 kHz) 30 to 300 MHz (120 kHz) 300 to 600 MHz (120 kHz)

600 MHz to 1 GHz (120 kHz)

1 to 2 GHz (1 MHz) 2 to 2.5 GHz (1 MHz) 2.5 to 3 GHz (1 MHz) 3 to 3.6 GHz (1 MHz) 3.5 to 8.4 GHz (1 MHz) Option 544 8.3 to 13.6 GHz (1 MHz) Option 544 13.5 to 17.1 GHz (1 MHz) 17.0 to 20.0 GHz (1 MHz) 20.0 to 26.5 GHz (1 MHz) 26.4 to 34.5 GHz (1 MHz) 34.4 to 44 GHz (1 MHz) + 17 dBuV 2 (nominal) +9 dBuV 2 +10 dBuV 2 +9 dBuV 2 –2 dBuV –13 dBuV –11 dBuV –13 dBuV –3 dBuV –6 dBuV –4 dBuV +6 dBuV +3 dBuV +4 dBuV +6 dBuV +8 dBuV +14 dBuV +9 dBuV +11 dBuV +16 dBuV +15 dBuV +21 dBuV +19 dBuV +24 dBuV RF preselector on, preamp on 1 kHz (100 Hz RBW) 3 9 kHz (200 Hz) 100 kHz (200 Hz) 1 to 2 MHz (9 kHz) 2 to 30 MHz (9 kHz) 30 to 600 MHz (120 kHz) 600 to 800 MHz (120 kHz)

800 MHz to 1 GHz (120 kHz)

1 to 2 GHz (1 MHz) 2 to 2.75 GHz (1 MHz) 2.75 to 3.6 GHz (1 MHz) 3.5 to 8.4 GHz (1 MHz) Option 544 8.3 to 13.6 GHz (1 MHz) Option 544 13.5 to 17.1 GHz (1 MHz) 17.0 to 20.0 GHz (1 MHz) 20.0 to 26.5 GHz (1 MHz) 26.4 to 34.5 GHz (1 MHz) 34.4 to 44 GHz (1 MHz) –4 dBuV 2 –24 dBuV –35 dBuV –31 dBuV –20 dBuV –8 dBuV –8 dBuV –9 dBuV +3 dBuV –1 dBuV +2 dBuV –5 dBuV –1 dBuV –6.0 dBuV –4 dBuV –4 dBuV +2 dBuV +5 dBuV +3 dBuV +9 dBuV 1. Typical Indicated Noise including NFE = Typical DANL+ Bandwidth and Log corrrections-DANL improvement with NFE 2. No NFE factor at this frequency. 3. Specified for instruments with prefixes MY/SG5213 or greater. Nominal for instruments with earlier prefixes. 13 | Keysight | N9038A MXE EMI Receiver - Data Sheet

RF Input 1; RF preselector on and off Source frequency Specification Typical Residual responses 1 (Input terminated and 0 dB attenuation) 200 kHz to 8.4 GHz (swept) Zero span or FFT or other frequencies –100 dBm –100 dBm (nominal) Image responses f ± 645 MHz Mixer level –10 dBm 10 MHz to 3.6 GHz 3.5 to 13.6 GHz 13.5 to 17.1 GHz 17.0 to 22 GHz 22 to 26.5 GHz 26.5 to 34.5 GHz 3 34.4 to 44 GHz 3 –80 dBc –78 dBc –74 dBc –70 dBc –68 dBc –70 dBc –60 dBc –108 dBc –88 dBc –85 dBc –82 dBc –78 dBc –94 dBc –79 dBc LO related spurious (f > 600 MHz from carrier) 10 MHz to 3.6 GHz –90 dBc + 20xlogN 2 Other spurious f ≥ 10 MHz from carrier Carrier frequency ≤ 26.5 GHz Carrier frequency > 26.5 GHz –80 dBc + 20xlogN 2 –90 dBc (nominal) Second harmonic distortion (SHI) RF Input 1; input power –9 dBm, input attenuation 6 dB; RF Input 2 to 1 GHz. RF Input 2 performance = RF Input 1 performance +9 dB Source frequency Specification Typical RF preselector off, preamp off 10 MHz to 1.0 GHz 1.0 to 1.8 GHz 1.8 to 6.8 GHz Option 544 1.8 to 3 GHz 3 to 6.8 GHz 6.8 to 11 GHz 11 to 13.25 GHz 13.2 to 22 GHz (Option 544) +45 dBm +41 dBm +65 dBm +58 dBm +60 dBm +55 dBm +50 dBm +44 dBm +54 dBm +50 dBm +68 dBm +64 dBm +69 dBm +64 dBm +60 dBm +51 dBm RF preselector off, preamp on Preamp power = –45 dBm Preamp power = –50 dBm 10 MHz to 1.8 GHz 1.8 to 13.25 GHz 13.2 to 22 GHz (Option 544) +33 dBm (nominal) +10 dBm (nominal) +0 dBm (nominal) RF preselector on, preamp off 10 to 30 MHz 30 to 500 MHz

500 MHz to 1GHz

1 to 1.6 GHz 1.6 to 1.8 GHz 1.8 to 6.8 GHz Option 544 1.8 to 3 GHz 3 to 6.8 GHz 6.8 to 11 GHz 11 to 13.25 GHz 13.2 to 22 GHz (Option 544) +47 dBm +57 dBm +46 dBm +58 dBm +46 dBm +65 dBm +58 dBm +60 dBm +55 dBm +50 dBm +44 dBm +50 dBm +63 dBm +48 dBm +70 dBm +52 dBm +68 dBm +64 dBm +69 dBm +64 dBm +60 dBm +51 dBm RF preselector on, preamp on, Input power = –9 dBm Attenuation = 26 dB Preamp power = –50 dBm 10 to 300 MHz 300 to 500 MHz

500 MHz to 1 GHz

1 to 1.6 GHz 1.6 to 1.8 GHz 1.8 to 13.25 GHz 13.2 to 22 GHz (Option 544) +53 dBm (nominal) +58 dBm (nominal) +47 dBm (nominal) +53 dBm (nominal) +30 dBm (nominal) +10 dBm (nominal) +0 dBm (nominal) 1. RF2 performance = RF1 performance +11 dB 2. N is the LO multiplication factor 3. Mixer level -30 dBm 14 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Figure 1. Nominal phase noise at different center frequencies

30 MHz to 1 GHz

  1. Preamp input power = input power-input attenuation (–9 dB for input 2).
  2. For nominal values, refer to Figure 1.

PowerSuite Measurement Specifications Channel power Amplitude accuracy, W-CDMA or IS95 (20 to 30 °C, at - tenuation = 10 dB) ± 0.82 dB (± 0.23 dB 95th percentile) Occupied bandwidth Frequency accuracy ± [span/1000] (nominal) Adjacent channel power Accuracy, W-CDMA (ACLR) (at specific mixer levels and ACLR ranges) Adjacent Alternate MS BTS ± 0.14 dB ± 0.49 dB ± 0.21 dB ± 0.44 dB Dynamic range (typical) Without noise correction With noise correction –73 dB –78 dB –79 dB –82 dB Offset channel pairs measured 1 to 6 ACP measurement and transfer time (fast method) 14 ms (nominal) (σ = 0.2 dB) Multiple number of carriers measured Up to 12 Power statistics CCDF Histogram resolution 0.01 dB Harmonic distortion Maximum harmonic number 10th Result Fundamental power (dBm), relative harmonics power (dBc), total harmonic distortion in % Intermod (TOI) Measure the third-order products and intercepts from two tones Burst power Methods Power above threshold, power within burst width Results Single burst output power, average output power, maximum power, minimum power within burst, burst width Spurious emission W-CDMA (1 to 3.6 GHz) table-driven spurious signals; search across regions Dynamic range Absolute sensitivity 96.7 dB –85.4 dBm 101.7 dB (typical) Spectrum emission mask (SEM) cdma2000 ® (750 kHz offset) Relative dynamic range (30 kHz RBW) Absolute sensitivity Relative accuracy 78.9 dB –100.7 dBm ± 0.12 dB 85 dB (typical) 3GPP W-CDMA (2.515 MHz offset) Relative dynamic range (30 kHz RBW) Absolute sensitivity Relative accuracy 81.9 dB –100.7 dBm ± 0.12 dB 88.2 dB (typical) 16 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Operating 0 to 55 °C Storage –40 to 70 °C EMC Complies with European EMC Directive 2004/108/EC – IEC/EN 61326-2-1 – CISPR Pub 11 Group 1, class B – AS/NZS CISPR 11 – ICES/NMB-001 This ISM device complies with Canadian ICES-001 Cet appareil ISM est conforme à la norme NMB-001 du Canada Radio disturbance measuring apparatus CISPR 16-1-1 The features in this instrument comply with the performance require - ments of this basic standard 1 Safety Complies with European Low Voltage Directive 2006/95/EC – IEC/EN 61010-1 2nd Edition – Canada: CSA C22.2 No. 61010-01-04 – USA: UL 61010-1 2nd Edition Acoustic noise emission Geraeuschemission LpA < 70 dB LpA < 70 dB Operator position Am Arbeitsplatz Normal position Normaler Betrieb Per ISO 7779 Nach DIN 45635 t.19 Environmental stress Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environmental stresses of storage, transportation, and end-use; those stresses include, but are not limited to, temperature, humidity, shock, vibration, altitude, and power line conditions; test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F Class 3 1. The use of Noise Floor Extension (NFE) is required to meet the “isolated pulse” test case in Bands B, C, and D. In addition, when making measurements in Band B below 160 kHz using time domain scans or making measurements using meters in monitor spectrum, NFE is also required to meet the 1 Hz pulse repetition frequency (prf) test case for the quasi-peak detector (QPD) and for the 5 Hz prf test case for the RMS-avg detector. 17 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Voltage and frequency (nominal) 100 to 120 V, 50/60/400 Hz 220 to 240 V, 50/60 Hz Power consumption On Standby

450 W maximum

Resolution 1024 x 768, XGA Size 213 mm (8.4 in.) diagonal (nominal) Data storage Internal ≥ 80 GB (nominal) (removable solid state drive) External Supports USB 2.0 compatible memory devices Weight (without options) Net 24 kg (52 lbs) (nominal) Shipping 36 kg (79 lbs) (nominal) Dimensions Height 177 mm (7.0 in) Width 431 mm (17.0 in) Length 535 mm (21.0 in) Warranty The MXE EMI receiver is supplied with a 3-year warranty Calibration cycle The recommended calibration cycle is one year; calibration services are available through Keysight service centers 18 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Type-N female, 50 Ω (nominal) (standard) 3.5 mm male, 50 Ω (Opt C35) 2.4 mm male, 50 Ω (Option 544 only) Type-N female, 50 Ω (nominal) (standard) External Mixing (Option EXM) Connection port Connector Impedance Functions Mixer bias range SMA, female 50 Ω, nominal Triplexed for LO output, IF input, and mixer bias ± 10 mA in 10 μA step IF input center frequency IF BW path <= 25 MHz

85 MHz BW IF path

322.5 MHz (note - please use the proper <= sign)

300 MHz

3.75 to 14.0 GHz Probe power Voltage/current +15 Vdc, ± 7% at 150 mA max (nominal) –12.6 Vdc, ± 10% at 150 mA max (nominal) USB 2.0 ports Master (2 ports) Standard Connector Output current Compatible with USB 2.0 USB Type-A female

0.5 A (nominal)

Connector Miniature stereo audio jack 3.5 mm Rear panel

10 MHz out

BNC female, 50 Ω (nominal) ≥ 0 dBm (nominal)

10 MHz × (1+ frequency reference accuracy)

BNC female, 50 Ω (nominal) –5 to 10 dBm (nominal) 1 to 50 MHz (nominal) ± 5 x 10–6 of specified external reference input frequency Trigger 1 and 2 inputs Connector Impedance Trigger level range BNC female > 10 kΩ (nominal) –5 to 5 V Trigger 1 and 2 outputs Connector Impedance Level BNC female 50 Ω (nominal) 0 to 5 V (CMOS) 19 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Rear panel (continued) Monitor output Connector Format Resolution VGA compatible, 15-pin mini D-SUB XGA (60 Hz vertical sync rates, non-interlaced) Analog RGB 1024 x 768 Noise source drive +28 V (pulsed) Connector BNC female SNS Series noise source For use with Keysight Technologies’ SNS series noise sources Analog out Connector BNC female (used by Option YAS) USB 2.0 ports Master (4 ports) Standard Connector Output current Slave (1 port) Standard Connector Compatible with USB 2.0 USB Type-A female Compatible with USB 2.0 USB Type-B female GPIB interface Connector GPIB codes GPIB mode IEEE-488 bus connector SH1, AH1, T6, SR1, RL1, PP0, DC1, C1, C2, C3, C28, DT1, L4, C0 Controller or device LAN TCP/IP interface Standard Connector 1000Base-T RJ45 Ethertwist Aux I/O connector Connector 25-pin D-SUB 20 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Resolution bandwidth (spectrum measurement) Range – Overall – Span = 1 MHz – Span = 10 kHz – Span = 100 Hz 100 mHz to 3 MHz

50 Hz to 1 MHz

1 Hz to 10 kHz

Flat top, Uniform, Hanning, Gaussian, Blackman, Blackman-Harris, Kaiser Bessel (K-B 70 dB, K-B 90 dB and K-B 110 dB) Analysis bandwidth Standard Option B25 Option B85

10 Hz to 10 MHz

10 Hz to 25 MHz

10 Hz to 85 MHz

IF frequency response (standard 10 MHz IF path) IF frequency response (demodulation and FFT response relative to the center frequency, 20 to 30 °C) Center frequency (GHz) Span (MHz) Microwave preselector Max. error RMS (nominal) ≤ 3.6 3.6 < f ≤ 26.5 f > 26.5 ≤ 10 ≤ 10 ≤ 10 NA On On ± 0.40 dB 0.04 dB 0.25 dB 0.35 dB IF phase linearity (deviation from mean phase linearity, nominal) Center frequency (GHz) Span (MHz) Microwave preselector Peak-to-peak (nominal) RMS (nominal) 0.02 < f ≤ 3.6 3.6 < f ≤ 26.5 ≤ 10 ≤ 10 NA On 0.4° 1.0° 0.1° 0.2° (nom) Data acquisition (10 MHz IF path) Time record length – IQ analyzer 4,000,000 IQ sample pairs Sample rate at ADC 100 MSa/s ADC resolution 16 bits I/Q Analyzer — Option B25

25 MHz analysis bandwidth

IF frequency response (demodulation and FFT response relative to the center frequency, 20 to 30 °C) Center frequency (GHz) Span (MHz) Microwave preselector Max. error RMS (nominal) ≤ 3.6 3.6 < f ≤ 44 10 to ≤ 25 10 to ≤ 25 NA On ± 0.45 dB 0.051 dB 0.45 dB IF phase linearity (deviation from mean phase linearity, nominal) Center frequency (GHz) Span (MHz) Microwave preselector Peak-to-peak (nominal) RMS (nominal) 0.02 ≤ f < 3.6 3.6 ≤ f ≤ 26.5 ≤ 25 ≤ 25 NA On 0.6° 4.5° 0.14° 1.2° Data acquisition (25 MHz IF path) Time record length (IQ pairs) – IQ analyzer 4,000,000 IQ sample pairs – 89600 VSA software Data packing 32-bit 64-bit Memory

536 MSa 268 MSa 2 GB

Sample rate at ADC 100 MSa/s ADC resolution 16 bits 21 | Keysight | N9038A MXE EMI Receiver - Data Sheet

I/Q Analyzer — Option B85

85 MHz analysis bandwidth

IF frequency response (20 to 30 °C) Relative to center frequency Center freq. (GHz) Span (MHz) Microwave preselector Typical RMS (nominal) IF phase linearity (deviation from mean phase linearity, nominal) Center freq. (GHz) Span (MHz) Microwave preselector Peak-to-peak (nominal) RMS (nominal) Dynamic range SFDR (Spurious-free dynamic range) – Signal frequency and spurious re - sponse anywhere within 85 MHz BW –76 dBc, nominal Full scale (ADC clipping) Default settings, signal at CF (IF gain = Low: IF gain offset = 0 dB) – Band 0 – Band 1 through 4 –8 dBm mixer level, nominal –7 dBm mixer level, nominal High gain setting, signal at CF (IF gain = High) – Band 0 – Band 1 through 4 –18 dBm mixer level nominal, subject to gain limitations –17 dBm mixer level nominal, subject to gain limitations Effect of signal frequency ≠ CF Up to ± 3 dB, nominal Data acquisition (85 MHz IF path) Time record length – IQ analyzer 4,000,000 IQ sample pairs – 89600 VSA software Data packing 32-bit 64-bit – Length (IQ sample pairs) 536 MSa (2 29 Sa) 268 MSa (228 Sa) 2 GB total memory – Length (time units) Samples/(span x 1.25) Sample rate – At ADC 400 Msa/s – IQ pairs Span dependent ADC resolution 14 bits 22 | Keysight | N9038A MXE EMI Receiver - Data Sheet

Real-Time Spectrum Analyzer (RTSA) 1 Option RT1 Real-time analysis Real-time analysis bandwidth – Option RT1 Up to 85 MHz ≤ 3.6GHz, Up to 40 MHz > 3.6 GHz Minimum signal duration with 100% probability of intercept (POI) at full amplitude accuracy – Option RT1 3.7 μs Minimum acquisition time 104 μs Spectrogram view only FFT rate 292,969/s Supported triggers Level, Level with time qualified (TQT), Line, External, RF burst, Frame, Frequency mask (FMT), FMT with TQT 1. For additional RTSA specifications, please refer to Option RT1 Chapter in the MXE Signal Analyzer specifications guide (part number: N9038- 90010) 23 | Keysight | N9038A MXE EMI Receiver - Data Sheet Related Literature Keysight MXE EMI receiver Publication title Publication number MXE EMI Receiver, Configuration Guide 5990-7419EN MXE EMI Receiver, Brochure 5990-7422EN

www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Infoline www.keysight.com/find/Infoline Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. KEYSIGHT SERVICES Keysight Services www.keysight.com/find/services Our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. The result? We help you implement new technologies and engineer improved processes that lower costs. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. cdma2000 is a US registered certification mark of the Telecommunications Industry Association. www.keysight.com/find/mxe For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-06-08-16) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System Evolving Our unique combination of hardware, software, support, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight 24 | Keysight | N9038A MXE EMI Receiver - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2012 - 2016 Published in USA, August 10, 2016 5990-7421EN www.keysight.com