N8812A KEYSIGHT | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
and Decode for Infiniium Series Oscilloscopes Data Sheet
SerialVID is a three wire (clock, data, alert) serial synchronous interface used to transfer power management information between a master (typically a microprocessor) and a slave (typically a voltage regulator controller). The bus will operate at a maximum frequency of 26.25 MHz. Since these protocols transfer bits serially, using a traditional oscilloscope has limitations. Manually converting captured 1’s and 0’s to protocol requires significant effort, can’t be done in real-time, and includes potential for human error. As well, traditional scope triggers are not sufficient for specifying protocol-level conditions. Extend your scope capability with the Keysight Technologies, Inc. SVID triggering and decode application. This application makes it easy to debug and test designs that include SVID buses using your Infiniium Series oscilloscope. – Set up your scope to show SVID protocol decode in less than 30 seconds. – Get access to a rich set of integrated protocol-level (Protocol trigger capability available with the 9000 series oscilloscope). – Save time and eliminate errors by viewing packets at the protocol level. – Use time-correlated views to quickly troubleshoot serial protocol problems back to their timing or signal integrity root cause. Easy to find Turn decode on/off via the “Serial Decode” button on the front of 9000 Series scopes or in the “Setup” menu. View decode embedded on the waveform display or in the protocol viewer listing window. 30 second SVID setup Configure your oscilloscope to display protocol decode in under 30 seconds. Use “Auto Setup” to automatically configure sample rate, memory depth, threshold and trigger levels for SVID. Support for both live and saved waveforms Perform and view decode information on both live and saved waveforms. Decode up to any combination of 4 live or saved waveforms. – Order N8812A for a user-installed license – Order option 046 for a factory-installed license with new
9000 Series oscilloscopes
– Order option 056 for a factory-installed license with 90000 or 90000 X Series oscilloscopes – Order N5435A option 054 for a server-based license that works on both 9000, 90000 and 90000 X Series oscilloscopes This application is available in the following license variations. 02 | Keysight | SVID Protocol Triggering and Decode for Infiniium Series Oscilloscopes - Data Sheet
SVID setup, protocol triggering, and search capabilities Get access to a rich set of integrated protocol level triggers. The application includes a suite of configurable protocol level trigger conditions specific to SVID. When serial trigger - ing is selected, the application enables special real-time triggering hardware inside the scope. Hardware-based trig - gering ensures that the scope never misses a trigger event when armed. This hardware takes signals acquired using either scope or digital channels and reconstructs proto - col frames. It then inspects these protocol frames against specified protocol-level trigger conditions and triggers when the condition is met. SVID trigger and search setup Quickly access the hardware-based trigger via the trigger or search menus. Hardware-based triggering enables quick setup of data, remote, or error frames. Specify the type. SVID Set, Get and other frames can be acquired. 03 | Keysight | SVID Protocol Triggering and Decode for Infiniium Series Oscilloscopes - Data Sheet
Keysight’s SVID protocol viewer includes correlation between the waveforms and the selected packet. The selected packet, highlighted blue row in the listing, is time-correlated with the blue line in the waveform display. Move the blue tracking marker in time through waveforms and the blue bar will automatically track in the packets window. Or, scroll through the packet viewer and highlight a specific packet. The time- correlation tracking marker will move to the associated point in the waveform. Quickly move between physical and protocol layer information using the time-correlated tracing marker. Display protocol content using embedded decode in the waveform area, Or, see protocol events in a compact listing format. View the decode information in symbols or packets type. Compact protocol using the full screen listing. The protocol viewer window shows the index number, time stamp value identifier, packet type, and data values for each SVID packet. Data in the listing window can be saved to a .csv or .txt file for off-line. SVID decode embedded in waveform area Utilize the oscilloscope waveform area to display decode information. Minor ticks indicate clock transitions and major ticks show segments within each SVID packet. 04 | Keysight | SVID Protocol Triggering and Decode for Infiniium Series Oscilloscopes - Data Sheet
SVID application specifications and characteristics SVID sources Analog channels 1, 2, 3, or 4 MSO models can additionally use digital channels D0 to D15 any waveform memory Maximum frequency Any waveform memories The application relies on probing and trigger/measurement thresholds to properly condition the signal for triggering and decode. Signal type Single ended Auto setup Automatically configures scope settings for proper SVID decode and SW-based protocol triggering including memory depth, edge triggering, holdoff, sample rate, and measurement thresholds Decoded fields All including extended frame format Triggering (hardware-based) Packet Types Set Get Set Rejected Get Rejected Errors Recommended oscilloscopes The SVID protocol triggering and decode software is compatible with Keysight Infiniium Series oscilloscopes with operating software revision 4.20 or higher. For oscilloscopes with earlier revisions, free upgrade software is available here: www.keysight. com/find/scope-apps-sw. Data rate Minimum bandwidth Minimum channels Compatible oscilloscopes Up to 26.25 MHz 1 GHz 3 Infiniium 9000, 90000, S-Series and Z-Series
Ordering information
Application License type Infiniium Z-Series Infiniium S-Series Infiniium 90000 Series Infiniium 9000 Series SVID protocol Fixed Factory-installed N8812A-1FP N8812B-1FP - - User-installed N8812A-1FP N8812B-1FP N8812A-1NL N8812B-1NL Floating Transportable N8812A-1TP N8812B-1TP N8812A-1TP 1,2 N8812B-1TP 1,2 Server-based N5435A-054 1. Requires software 5.00 and above. 2. Software 4.30 or above requires Windows 7. N2753A Infiniium Windows XP to 7 OS upgrade kit (oscilloscope already has M890 motherboard). N2754A Infiniium Windows XP to 7 OS and M890 motherboard upgrade kit (oscilloscope without M890 motherboard). Verify the M890 motherboard using the procedure found in the Windows 7 upgrade kit data sheet with the publication number 5990-8569EN. 05 | Keysight | SVID Protocol Triggering and Decode for Infiniium Series Oscilloscopes - Data Sheet
Multiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applications Related literature Publication title Publication type Publication number Infiniium 9000 Series Oscilloscopes Data sheet 5990-3746EN Infiniium 90000 Series Oscilloscopes Data sheet 5989-7819EN Infiniium 90000 X-Series Oscilloscopes Data sheet 5990-5271EN Infiniium S-Series Oscilloscopes Data sheet 5991-3904EN Infiniium Z-Series Oscilloscopes Data sheet 5991-3868EN 06 | Keysight | SVID Protocol Triggering and Decode for Infiniium Series Oscilloscopes - Data Sheet
www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/N8812A For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-10-14) 07 | Keysight | SVID Protocol Triggering and Decode for Infiniium Series Oscilloscopes - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2012 - 2014 Published in USA, August 2, 2014 5991-0412EN www.keysight.com