N8480 Series Thermocouple Power Sensors Data Sheet
The Keysight Technologies, Inc. N8480 Series thermocouple power sensors are amongst the most accurate and reliable sensors, plus they include EEPROM, and extended frequency and power ranges. Accurate, repeatable measurements Here’s how: Excellent linearity (1% approximately) and noise specifications. The sensors’ low SWR further enhances accuracy by minimizing mismatch uncertainty. These sensors also come with dual-range power for greater sensitivity to fluctuating signals. With high accuracy and stability, the N8480 helps you test confidently, faster. Calibration-easy testing During test, calibrating your sensor is an essential step. Minimizing the time this step takes is essential. The N8480 sensor eliminates cumbersome keying-in of the calibration factor (CF), eliminates manual input errors, and saves you time and effort. CF, linearity, and temperature corrections are all stored in the sensors’ EEPROM—auto-downloaded on calibration. The N8480 Series streamlines the calibration procedure making overall testing faster and more efficient. One sensor, WIDEST range Pick an N8480 sensor—any one—and you’ll see how its wide dynamic range equips you for various applications: metrology labs, radar, mobile radio, TDMA, GSM, W-CDMA, and WiMAX™, among others. With up to 55 dBm wide dynamic range, the N8480 Series offers you the widest thermocouple sensor power range in the industry. System integration can be difficult, but not with the N8480 The N8480 Series sensors are backward compatible with the Keysight leading range of power meters, including the P-Series, EPM-P Series, and EPM Series. All that’s needed is a simple firmware upgrade that’s downloadable for free from the Website. All SCPI codes used on the E-Series sensors are re-usable on the N8480, including most of the codes used on the 8480 Series. When migrating code from the 8480 Series, Option CFT 1 will allow SCPI codes to behave much like they do on the 8480 Series.
Features
– High accuracy with excellent linearity and noise specifications – Wide dynamic range in a single sensor – Auto-download of calibration factor and corrections from EEPROM – Option CFT provides full-code compatibly between sensors and the 8480 Series (excluding the N8488A) – Broad compatibility with existing power meters: P-Series (N1911A/12A), EPM-P Series (E4416A/17A), and EPM Series (N1913A/14A, E4418B/19B) 1. Option CFT is not available for the N8488A power sensor.
03 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Specification Definitions There are two types of product specifications: – Warranted specifications – Characteristic specifications Warranted specifications Warranted specifications are covered by the product warranty and apply over 0 to 55 °C, unless otherwise noted. Warranted specifications include measurement uncertainty calculated with 95% confidence. Characteristic specifications Characteristic specifications are not warranted. They describe product performance that is useful in the application of the power sensors by giving typical, but non-warranted performance parameters. These characteristics are shown in italics or denoted as “typical,” “nominal” or “approximate.” Characteristic information is representative of the product. In many cases, it may also be supplemental to a warranted specification. Characteristic specifications are not verified on all power sensors. The types of characteristic specifications can be placed in two groups: – The first group of characteristic types describes ‘attributes’ common to all products of a given model or option. Examples of characteristics that describe attributes are product weight and 50 -Ω input Type-N connector. In these examples, product weight is an approximate value and a 50-Ω input is nominal. These two terms are most widely used when describing a product’s attributes. – The second group of characteristic types describes ‘statistically’ the aggregate performance of the population of products. These characteristics describe the expected behavior of the population of products. They do not guarantee the performance of any individual product. No measurement uncertainty value is accounted for in the specification. These specifications are referred to as typical. Conditions The power meter and power sensor meet their specifications when: – Stored for a minimum of two hours at a stable temperature within the operating temperature range and turned on for at least 30 minutes – The power meter and power sensor are within their recommended calibration periods – Used in accordance to the information provided in the power meter’s user’s guide
04 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics Specifications stated hereon refer to all N8480 Series power sensors, unless otherwise stated. The term “standard” refers to all N8480 Series sensors except Option CFT. Frequency and dynamic power range Sensor option Sensor model Frequency range Dynamic power range Standard N8481A N8482A N8485A N8485A - Option 33 N8487A N8488A N8486AR N8486AQ
10 MHz to 18 GHz
10 MHz to 26.5 GHz
10 MHz to 33 GHz
50 MHz to 50 GHz
10 MHz to 67 GHz,
67 GHz to 70 GHz
26.5 to 40 GHz 33 to 50 GHz –35 to +20 dBm N8481B N8482B –5 to +44 dBm N8481H N8482H –15 to +35 dBm Option CFT N8481A N8482A N8485A N8485A - Option 33 N8487A N8486AR N8486AQ 10 MHz to 26.5 GHz 26.5 to 40 GHz 33 to 50 GHz –30 to +20 dBm N8481B N8482B –10 to +35 dBm Damage level Sensor model Damage level (average power) Damage level (peak power) N8481A N8482A N8485A N8487A N8488A N8486AR N8486AQ +25 dBm 15 W/2 μs N8481B N8482B +49 dBm 500 W/1 μs N8481H N8482H +40 dBm 100 W/1 μs
05 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Maximum SWR 1 Maximum SWR Sensor model Frequency band 25 ± 10 °C 0 to 55 °C N8481A 10 to 30 MHz 30 to 50 MHz
50 MHz to 2 GHz
2 to 12.4 GHz 12.4 to 18 GHz 1.37 1.14 1.08 1.16 1.23 1.57 1.16 1.11 1.16 1.25 N8482A 100 to 300 kHz 300 kHz to 1 MHz
1 MHz to 2 GHz
1.54 1.17 1.06 1.07 1.57 1.17 1.06 1.08 N8485A 10 to 50 MHz 50 to 100 MHz
100 MHz to 2 GHz
2 to 12.4 GHz 12.4 to 18 GHz 18 to 26.5 GHz 26.5 to 33 GHz 2 1.33 1.08 1.05 1.14 1.19 1.26 1.32 1.53 1.11 1.07 1.14 1.20 1.28 1.36 N8487A 50 to 100 MHz 2 to 12.4 GHz 12.4 to 18 GHz 18 to 26.5 GHz 26.5 to 40 GHz 40 to 50 GHz 1.08 1.05 1.10 1.16 1.22 1.30 1.34 1.10 1.07 1.10 1.16 1.22 1.30 1.33 N8488A 10 to 100 MHz 100 MHz to 2.4 GHz 2.4 to 12.4 GHz 12.4 to 18 GHz 18 to 26.5 GHz 26.5 to 40 GHz 40 to 67 GHz 67 to 70 GHz 1.08 1.08 1.10 1.12 1.21 1.30 1.46 1.48 1.08 1.08 1.10 1.14 1.23 1.31 1.47 1.50 N8486AR 50 MHz 3 26.5 to 40 GHz 1.17 1.40 1.20 1.40 N8486AQ 50 MHz 3 33 to 50 GHz 1.17 1.50 1.20 1.50 N8481B 10 MHz to 2 GHz 2 to 12.4 GHz 12.4 to 18 GHz 1.09 1.14 1.23 1.10 1.18 1.28 N8482B 100 kHz to 2 GHz 2 to 6 GHz 1.08 1.16 1.10 1.18 N8481H 10 MHz to 8 GHz 8 to 12.4 GHz 12.4 to 18 GHz 1.16 1.22 1.32 1.16 1.22 1.41 N8482H 100 kHz to 6 GHz 1.13 1.14 1. For overlapping frequency points, refer to the lower SWR specification. 2. Only applicable for N8485A Option 033. 3. SWR for 50 MHz calibration port. Type-N (m) coaxial connector is used in the 50 MHz calibration.
06 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) 1.20 1.18 1.16 1.14 1.12 1.10 1.08 1.06 1.04 1.02 0 2 4 6 8 10 12 14 16 18 Frequency GHz SWR 1.04 1.03 1.02 1.01 0 1 2 3 4 5 6 Frequency GHz SWR 1.20 1.18 1.16 1.14 1.12 1.10 1.08 1.06 1.04 1.02 0 5 10 15 20 25 30 35 Frequency GHz SWR 1.20 1.18 1.16 1.14 1.12 1.10 1.08 1.06 1.04 1.02 0 10 20 30 40 50 60 Frequency GHz SWR 1.30 1.25 1.20 1.15 1.10 1.05 0 10 20 30 40 50 60 70 Frequency GHz SWR 1.41 1.36 1.31 1.26 1.21 1.16 1.11 33 36 39 42 45 48 51 Frequency GHz SWR Typical SWR, 10 MHz to 18 GHz (25 ± 10 °C) for N8481A sensor Typical SWR, 100 kHz to 6 GHz (25 ± 10 °C) for N8482A sensor Typical SWR, 10 MHz to 26.5 GHz (25 ± 10 °C) for N8485A sensor Typical SWR, 50 MHz to 50 GHz (25 ± 10 °C) for N8487A power sensor Typical SWR, 10 MHz to 70 GHz (25 ± 10 °C) for N8488A power sensor Typical SWR, 33 to 50 GHz (25 ± 10 °C) for N8486AQ power sensor
07 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) 1.22 1.20 1.18 1.16 1.14 1.12 1.10 1.08 1.06 1.04 26.5 29 31.5 34 36.5 39 41.5 Frequency GHz SWR 1.08 1.07 1.06 1.05 1.04 1.03 1.02 1.01 0 2 4 6 8 10 12 14 16 18 20 Frequency GHz SWR 1.028 1.026 1.024 1.022 1.020 1.018 1.016 1.014 1.012 1.01 0 1 2 3 4 5 6 7 Frequency GHz SWR 1.24 1.22 1.20 1.18 1.16 1.14 1.12 1.10 1.08 1.06 1.04 1.02 0 2 4 6 8 10 12 14 16 18 20 Frequency GHz SWR 1.09 1.08 1.07 1.06 1.05 1.04 1.03 1.02 1.01 0 1 2 3 4 5 6 7 Frequency GHz SWR Typical SWR, 26.5 to 40 GHz (25 ± 10 °C) for N8486AR power sensor Typical SWR, 10 MHz to 18 GHz (25 ± 10 °C) for N8481B power sensor Typical SWR, 100 kHz to 6 GHz (25 ± 10 °C) for N8482B power sensor Typical SWR, 10 MHz to 18 GHz (25 ± 10 °C) for N8481H power sensor Typical SWR, 100 kHz to 6 GHz (25 ± 10 °C) for N8482H power sensor
08 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Power linearity 1 The N8480 Series power sensors’ linearity is negligible except for the power range specified in the table below. Sensor model Power range Linearity (25 ± 10 °C) Linearity (0 to 55 °C) N8481A, N8482A, N8485A, N8487A, N8488A, N8486AR, N8486AQ N8481B, N8482B +29 to < +39 dBm ± 0.52% ± 0.80% N8481H, N8482H +17 to < +30 dBm ± 0.77% ± 1.05% 1. After zero and calibration at ambient environment conditions% Error 0.5 –0.5 50–5 10 15 20 25 Input power (dBm) % Error 1.0 0.8 0.6 0.4 0.2 –0.2 –0.4 –0.6 –0.8 –1.0 5 10 15 20 25 Input power (dBm) % Error 1.0 0.8 0.6 0.4 0.2 –0.2 –0.4 –0.6 –0.8 –1.0 50–5 10 15 20 25 Input power (dBm) Typical N8481A/2A/5A/7A/8A and N8486AR/AQ power linearity at 25 °C, after zero and calibration with associated measurement uncertainty Typical N8481B/2B power linearity at 25 °C, after zero and calibration with associated measurement uncertainty Typical N8481H/2H power linearity at 25 °C, after zero and calibration with associated measurement uncertainty Power level Measurement uncertainty –1 to +20 dBm ± 0.35% Power level Measurement uncertainty 29 to 40 dBm ± 0.35% 40 to 44 dBm ± 1.21% Power level Measurement uncertainty 17 to 30 dBm ± 0.60% 30 to 35 dBm ± 2.39%
09 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Zero set, zero drift and measurement noise Sensor model Sensor option Range Conditions (RH) 1 Zero set 4 Zero drift 2, 4 Measurement noise 3, 4 N8481A, N8482A, N8485A, N8487A, N8486AR, N8486AQ Standard Upper up to 70% ± 63 nW < ± 7 nW < 114 nW Lower up to 70 % ± 25 nW < ± 3 nW < 80 nW Option CFT N/A 5 up to 70% ± 63 nW < ± 7 nW < 114 nW N8488A Standard Upper up to 70% ± 63 nW < ± 7 nW < 114 nW Lower up to 70 % ± 25 nW < ± 3 nW < 80 nW Option CFT N/A 5 N/A 5 N/A 5 N/A 5 N/A 5 N8481B, N8482B Standard Upper up to 70% ± 63 μW < ± 7 μW < 114 μW Lower up to 70 % ± 25 μW < ± 3 μW < 80 μW Option CFT N/A 5 up to 70% ± 63 μW < ±7 μW < 114 μW N8481H, N8482H Standard Upper up to 70% ± 63 μW < ± 0.7 μW < 11.4 μW Lower up to 70 % ± 2.5 μW < ± 0.3 μW < 8 μW Option CFT N/A 5 up to 70% ± 6.3 μW < ± 0.7 μW < 11.4 μW 1. RH is the abbreviation for relative humidity. 2. Average hourly drift, at constant temperature. If there is an abrupt change of temperature, it is strongly recommended to perform zeroing or waiting for 30 minutes before taking the measurement. 3. The number of averages at 16 for normal mode and 32 for x2 mode, at a constant temperature, measured over one-minute interval and two standard deviations. 4. The zero set, zero drift, and measurement noise specifications are tested at 50 MHz. 5. N/A is the abbreviation for “not applicable.” Effects of averaging on noise Averaging over 1 to 1024 readings is available for reducing noise. The table below provides the measurement noise for a particular sensor with the number of averages set at 16 (for normal mode) and 32 (for x2 mode). Use the noise multiplier, for the appropriate mode (normal or x2) and number of averages, to determine the total measurement noise value. Example: N8481A power sensor, normal mode, number of averages = 4 Measurement noise calculation: < 80 nW x 2.75 = < 220 nW Number of averages 1 2 4 8 16 32 64 128 256 512 1024 Noise multiplier
10 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Switching point The N8480 Series power sensors (excluding Option CFT) have two measurement ranges: a lower power range and an upper power range. The power meter automatically selects the proper power level range. To avoid unnecessary switching when the power level is near the switch point, switching point hysteresis has been added. N8481A/82A/85A/87A/88A and N8486AQ/AR power sensors This hysteresis causes the lower power range to remain selected until approximately –0.5 dBm as the power level is increased. Above this power, the upper power range is selected. Likewise, the upper power range remains selected until approximately –1.5 dBm as the signal level decreases. Below this power, the lower power range is selected. N8481B/82B power sensors This hysteresis causes the lower power range to remain selected until approximately 29.5 dBm as the power level is increased. Above this power, the upper power range is selected. Likewise, the upper power range remains selected until approximately 28.5 dBm as the signal level decreases. Below this power, the lower power range is selected. N8481H/82H power sensors This hysteresis causes the lower power range to remain selected until approximately 17.5 dBm as the power level is increased. Above this power, the upper power range is selected. Likewise, the upper power range remains selected until approximately 16.5 dBm as the signal level decreases. Below this power, the lower power range is selected. Power range in range setting Sensor Range setting Lower range Upper range N8481A/82A/85A/87A/88A and N8486AQ/AR excluding Option CFT AUTO (default) –35 to –1 dBm –1 to +20 dBm LOWER –35 to –1 dBm — UPPER 1 — –30 to +20 dBm N8481B/82B excluding Option CFT AUTO (default) –5 to +29 dBm +29 to +44 dBm LOWER –5 to +29 dBm — UPPER 1 — 0 to +44 dBm N8481H/82H excluding Option CFT AUTO (default) –15 to +17 dBm +17 to +35 dBm LOWER –15 to +17 dBm — UPPER 1 — –10 to +35 dBm 1. Recommended for pulse signals measurement with period of more than one second
11 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Settling time 1 Manual filter, 10-dB decreasing power step for normal and x2 modes (not across switching point) Number of averages 1 2 4 8 16 32 64 128 256 512 1024 Settling time (s) 1. Settling time: 0 to 99% settled readings over the GPIB Typical settling times x2 mode Normal mode 150 ms 150 ms 180 ms 200 ms 400 ms 1 s 3.6 s 6.6 s 6.6 s 13.5 s 20 dB 10 dB 10 dB 10 dB 5 dB Sensor dynamic range Maximum dBm Minimum dBm Auto filter, default resolution, 10-dB decreasing power step for normal and x2 modes (not across switching point) Calibration factor and reflection coefficient Calibration factor (CF) and reflection coefficient (Rho) data are unique to each sensor. The CF corrects for the frequency response of the sensor. The Keysight EPM Series, EPM-P Series, and P-Series power meters automatically read the CF data stored in the sensor’s EEPROM and use it to make the corrections. The reflection coefficient (Rho or r) relates to the SWR according to the following formula: SWR = 1 + r 1 – r Typical measurement uncertainties of the calibration factor (CF) are listed in the following table. There is only one set of CF data used for both the high and low range of each sensor. The typical measurement uncertainty data listed in the table is meant to help users on the measurement uncertainty estimation. These values are only a guideline and are not to be used in any accurate uncertainty calculations. For accurate measurement uncertainty values, please refer to the measurement report 1 of the specific sensor. 1. Only applicable with the purchase of Option 1A7 or Option A6J
12 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Calibration factor uncertainty The typical measurement uncertainties listed are not to be taken as the maximum CF measurement uncertainties. 25 ± 3 °C Frequency N8481A N8481B N8481H N8482A N8482B N8482H N8485A N8487A N8486AR N8486AQ 100 kHz to 10 MHz — — — 0.91 1.48 0.89 — — — — 33 to 34 GHz — — — — — — — 2.80 3.19 3.14 34 to 35 GHz — — — — — — — 2.80 3.19 3.40 35 to 40 GHz — — — — — — — 2.80 3.19 3.14 25 ± 3 °C Frequency N8488A 100 kHz to 50 MHz 1.70 50 to 100 MHz 1.60 100 MHz to 2 GHz 1.58 2 to 12.4 GHz 1.75 12.4 to 18 GHz 1.92 18 to 26.5 GHz 2.43 26.5 to 50 GHz 4.56 50 to 67 GHz 5.30 67 to 70 GHz 5.81
13 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Calibration factor uncertainty (continued) The typical measurement uncertainties listed are not to be taken as the maximum CF measurement uncertainties. 25 ± 10 °C Frequency N8481A N8481B N8481H N8482A N8482B N8482H N8485A N8487A N8486AR N8486AQ 100 kHz to 10 MHz — — — 1.28 2.40 0.99 — — — — 33 to 34 GHz — — — — — — — 4.55 4.07 5.02 34 to 35 GHz — — — — — — — 4.55 4.07 4.99 35 to 40 GHz — — — — — — — 4.55 4.07 5.02 25 ± 10 °C Frequency N8488A 100 kHz to 50 MHz 2.83 50 to 100 MHz 1.98 100 MHz to 2 GHz 1.84 2 to 12.4 GHz 2.45 12.4 to 18 GHz 2.89 18 to 26.5 GHz 3.52 26.5 to 50 GHz 4.99 50 to 67 GHz 6.46 67 to 70 GHz 7.29
14 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Calibration factor uncertainty (continued) The typical measurement uncertainties listed are not to be taken as the maximum CF measurement uncertainties. 0 ± 55 °C Frequency N8481A N8481B N8481H N8482A N8482B N8482H N8485A N8487A N8486AR N8486AQ 100 kHz to 10 MHz — — — 1.59 2.67 1.41 — — — — 33 to 34 GHz — — — — — — — 4.84 4.25 6.04 34 to 35 GHz — — — — — — — 4.84 4.25 6.04 35 to 40 GHz — — — — — — — 4.84 4.25 6.04 0 ± 55 °C Frequency N8488A 100 kHz to 50 MHz 3.69 50 to 100 MHz 2.63 100 MHz to 2 GHz 2.40 2 to 12.4 GHz 2.61 12.4 to 18 GHz 3.15 18 to 26.5 GHz 4.50 26.5 to 50 GHz 5.67 50 to 67 GHz 7.18 67 to 70 GHz 8.69
15 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) Typical CF and SWR versus frequency The chart below shows supplemental characteristics intended to provide additional information, useful in applying the power sensor by giving typical but not warranted performance parameters. 100 1.25 1.2 1.15 1.1 1.05 0.95 0.9 27231815128410.05 Frequency GHz SWR Cal factor Typical CF Typical SWR
16 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Performance Characteristics (continued) General specifications Dimensions and weight Dimensions (W x H x L) N8481A/82A: 38 mm W x 30 mm H x 130 mm L N8485A: 38 mm W x 30 mm H x 121 mm L N8487A: 38 mm W x 30 mm H x 121 mm L N8488A: 38 mm W x 30 mm H x 115 mm L N8486AR: 38 mm W x 62 mm H x 152 mm L N8486AQ: 38 mm W x 62 mm H x 152 mm L N8481B/82B: 83 mm W x 114 mm H x 283 mm L N8481H/82H: 38 mm W x 30 mm H x 174 mm L Weight N8481A/2A: Net: 0.181 kg (0.40 lb) Shipping: 0.90 kg (1.98 lb) N8485A: Net: 0.183 kg (0.40 lb); Shipping: 0.90 kg (1.98 lb) N8487A: Net: 0.154 kg (0.34 lb); Shipping: 0.874 kg (1.92 lb) N8488A: Net: 0.162 kg (0.36 lb); Shipping: 0.881 kg (1.94 lb) N8486AR: Net: 0.202 kg (0.45 lb); Shipping: 0.922 kg (2.03 lb) N8486AQ: Net: 0.204 kg (0.45 lb); Shipping: 0.924 kg (2.03 lb) N8481B/82B: Net: 0.684 kg (1.51 lb); Shipping: 1.404 kg (3.09 lb) N8481H/82H: Net: 0.234 kg (0.52 lb); Shipping: 0.954 kg (2.10 lb) Operating environment Temperature 0 to 55 °C Humidity Maximum: 95% RH at 40 °C non-condensing Altitude Up to 4600 m (15,000 ft) Storage conditions Temperature –40 to 70 °C Humidity Up to 90% RH at 65 °C non-condensing Altitude Up to 4600 m (15,000 ft) Other Connector 1 N8481A/82A: N-type (male) N8485A: 3.5 mm (male) N8487A: 2.4 mm (male) N8488A: 1.85 mm (male) N8481B/82B: N-type (male) N8481H/82H: N-type (male) N8486AR: Waveguide flange UG-599/U N8486AQ: Waveguide flange UG-383/U Programming language Standard: SCPI code-compatible to E-Series sensors Option CFT: SCPI code-compatible to 8480 Series sensors Safety and EMC compliance IEC 61326-2002/EN 61326:1997+A1:1998+A3:2003 Canada: ICES-001:2004, ICES/NMB-001:2004 Australia/New Zealand: AS/NZS CISPR11:2004 Calibration interval 1 year Warranty 1 3 years 1. See “Ordering Information” for available options Length (L) Height (H) Width (W)
17 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet
Ordering Information
Standard power sensors Description Frequency range Power range N8481A Standard N8481A model with EEPROM feature 10 MHz to 18 GHz –35 to +20 dBm N8482A Standard N8482A model with EEPROM feature 100 kHz to 6 GHz –35 to +20 dBm N8485A Standard N8485A model with EEPROM feature 10 MHz to 26.5 GHz –35 to +20 dBm N8487A Standard N8487A model with EEPROM feature 50 MHz to 50 GHz –35 to +20 dBm N8488A Standard N8488A model with EEPROM feature 10 MHz to 67 GHz –35 to +20 dBm N8481B Standard N8481B model with EEPROM feature 10 MHz to 18 GHz –5 to +44 dBm N8482B Standard N8482B model with EEPROM feature 100 kHz to 6 GHz –5 to +44 dBm N8481H Standard N8481H model with EEPROM feature 10 MHz to 18 GHz –15 to +35 dBm N8482H Standard N8482H model with EEPROM feature 100 kHz to 6 GHz –15 to +35 dBm N8486AR Standard N8486AR model with EEPROM feature 26.5 to 40 GHz –35 to +20 dBm N8486AQ Standard N8486AQ model with EEPROM feature 33 to 50 GHz –35 to +20 dBm Other sensor options Description Option CFT N8480 sensor without the calibration factor table stored in the EEPROM. Calibration factor data is provided on the label attached to the power sensor N8485A-033 N8485A model with EEPROM feature with extended frequency range, 10 MHz to 33 GHz Standard-shipped Description Shipped as standard with every power sensor – Certificate of Calibration – Operating and Service Guide – Product Reference CD (contains Migration Guide, Operating and Service Guide, firmware upgrades for EPM, EPM-P, and P-Series power meters, and upgrade procedures)
18 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Ordering Information (continued) Accessories, calibration and documentation options Connectors Description Option 100 – Type-N (male) connector for N8481A/N8482A/N8481B/N8482B/N8481H/N8482H – 3.5 mm (male) connector for N8485A – 2.4 mm (male) connector for N8487A – 1.85 mm (male) connector for N8488A – Waveguide connector for N8486AR/N8486AQ Option 200 APC-7 (male) connector for N8481A only Cables Description 11730A For EPM Series power meters: 1.5 m (5 ft), grey 11730B For EPM Series power meters: 3 m (10 ft), grey 11730C For EPM Series power meters: 6.1 m (20 ft), grey 11730D For EPM Series power meters: 15.2 m (50 ft), grey 11730E For EPM Series power meters: 30.5 m (100 ft), grey 11730F 1 For EPM Series power meters: 61 m (200 ft), grey *operates up to 45 °C E9288A For EPM and EPM-P Series power meters: 1.5 m (5 ft), blue E9288B For EPM and EPM-P Series power meters: 3 m (10 ft), blue E9288C For EPM and EPM-P Series power meters: 10 m (31 ft), blue N1917A For P-Series power meters: 1.5 m (5 ft) N1917B For P-Series power meters: 3 m (10 ft) N1917C For P-Series power meters: 10 m (31 ft) Calibration Description Option 1A7 ISO 17025 calibration with test data Option A6J ANSI Z540 calibration with test data Warranty Description Option R-51B-001-3C Return to Keysight Technologies Warranty - 3 years Option R-51B-001-5C Warranty Assurance Plan - Return to Keysight Technologies - 5 years Documentation Description Option OB1 English language Operating and Service Guide Option ABJ Japanese localization Operating and Service Guide 1. Only applicable for E4418/19B power meters
19 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Where Does the N8480 Fit in Keysight’s Average Power Sensors Offering? Sensor technology Signal characteristics > CW Modulated CW Pulse/ averaged AM/FM profiled Wireless standards Typical application examples > Metrology lab Radar/ navigation Mobile radio TDMA GSM EDGE NADC IDEN cdmaOne Bluetooth® W-CDMA cdma2000 ® 802.11a /b/g MCPA HiperLan2 WiMAX Themocouple sensors 8480A/B/H, N8480A/B/H/R/Q, 8486A, N8486AR/AQ Y Y Y Y Average only Y Average only Y Average only Y Average only Diode sensors 8480D, V8486A, W8486A Y Y Y Y Average only Y Average only Y Average only Y Average only Diode sensors compensated for extended range E4412A/3A Y FM only Two-path diode-stack sensors E9300 Series Y Y Y Y Average only Y Average only Y Average only Y Average only
20 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Where Does the N8480 Fit in Keysight’s Average Power Sensors Offering? 9 kHz 100 kHz
10 MHz
50 MHz
2 GHz
4.2 GHz
6 GHz
18 GHz
26.5 GHz
33 GHz
40 GHz
50 GHz
75 GHz
110 GHz
Peak-and-average power sensors (breakdown by dynamic range) 9 kHz 100 kHz
24 GHz
(breakdown by dynamic range) –65 to +20 dBm –60 to +20 dBm –35 to +20 dBm N848XB Series –5 to +44 dBm E930XB Series –30 to +44 dBm U200XB Series –30 to +44 dBm N848XH Series –15 to +35 dBm U200XH Series –50 to +30 dBm E930XA Series –60 to +20 dBm U200XA Series –60 to +20 dBm 848XD Series –70 to –20 dBm 848XA Series –30 to +20 dBm N848XA Series –35 to +20 dBm E441XA Series –70 to +20 dBm E930XA/H Series –50 to +30 dBm V3500A –63 dBm to +20 dBm E9321A (300 kHz BW) E9325A (300 kHz BW) N1921A (30 MHz BW) N1922A (30 MHz BW) E9322A (1.5 MHz BW) E9323A (5 MHz BW) E9326A (1.5 MHz BW) E9327A (5 MHz BW) N8481B N8482B E9300B E9301B U2001B U2000B N8481H N8482H E9300H E9301H E9304A OPT-H19 E9300A OPT-H25 N8486AQ N8486AR N8485A OPT-33 N8487A N8482A N8481A U2004A U2002A U2000A U2001A V3500A U2002H U2001H V8486A W8486A 8483A (75 Ω) U2000H E9300A OPT-H24 E9301A 8487D Q8486D 8485D OPT-33 R8486D 8481D E4413A OPT-H33 E4412A E9304A OPT-H18 N848X average thermocouple sensor 848XD average diode sensor 848X thermocouple sensor E441X 1-path diode CW-only sensor E930X 2-path diode true-average sensor U200X USB sensors V3500A handheld RF power meter Legend N192x peak-and-average sensors compatible with P-Series power meters E932x peak-and-average sensors compatible with EPM-P and P-Series power meters Legend
21 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Compatible Power Meters The N8480 Series power sensors perform accurate, repeatable average power measurements with the following power meters: Keysight N1911A/12A P-Series power meters – Single (N1911A) and dual (N1912A) channels – High resolution color display – 30 MHz video bandwidth – 100 MSa/s continuous sampling rate – Time-gated and free-run measurement modes – Rise time, fall time, pulse width, time to positive occurrence, and time to negative occurrence measurements – Includes predefined configurations for WiMAX, HSDPA, and DME – GPIB, LAN, and USB interfaces – Code-compatible with EPM-P and EPM Series power meters – Optimized for peak power measurements and CCDF statistical analysis with the P-Series power sensors – Also compatible Compatible with all E-Series, N8480 Series, and 8480 Series power sensors Keysight E4416A/17A EPM-P Series power meters – Single (E4416A) and dual (E4417A) channels – 5 MHz video bandwidth – 20 MSa/s continuous sampling rate – Time-gated and free-run measurement modes – Includes predefined configurations for GSM, EDGE, NADC, iDEN, Bluetooth, IS-95 CDMA, W-CDMA, and cdma2000 – GPIB, RS-232/422 interfaces – Code-compatible with EPM Series power meters – Optimized for peak power measurements with the E9320 E-Series power sensors – Also compatible with the E9300 and E4410 E-Series, 8480, and N8480 Series power sensors Keysight N1913A/14A EPM Series power meters – Single (N1913A) and dual (N1914A) channels – Two optional USB channels available for four-channel measurements – Frequency range of 9 kHz to 110 GHz – Power range of –70 to +44 dBm (depending on the attached power sensor) – Fast measurement speed of 400 readings/s – Industry’s first color LCD screen for average power meters – USB and LAN/LXI-C connectivity on top of the standard GPIB – Automatic frequency/power sweep measurements with the optional trigger IN/OUT feature – Code-compatible with legacy E4418B/9B EPM Series, 436A, 437B, and 438A power meters (43X compatibility only with option N191xA-200) – Optimized for average power measurements with the U2000, E9300 and E4410, N8480, and 8480 Series power sensors 1. Note: The N8480 Series is also compatible with the E4418B/19B Series EPM power meters
22 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet Compatible Power Meters To get your existing power meters up-and-running in supporting the N8480 Series, just download their firmware upgrades online at www.keysight.com > Technical Support > Drivers & Software > Firmware Update Power meter Model number Compatible firmware revision EPM Series power meters E4418B A1.09.01 and above E4419B A2.09.01 and above N1913A A.01.00 and above N1914A A.01.00 and above EPM-P Series power meters E4416A A1.05.01 and above E4417A A2.05.01 and above P-Series power meters N1911A A.05.02 and above N1912A A.05.02 and above
This information is subject to change without notice. © Keysight Technologies, 2012 - 2015 Published in USA, November 12, 2015 5989-9333EN www.keysight.com myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a full one-year warranty on all accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. WiMAX is a US trademark of the WiMAX Forum. Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG, Inc., U.S.A. and licensed to Keysight Technologies. cdma2000 is a US registered certification mark of the Telecommunications Industry Association. www.keysight.com/find/thermocouplesensor From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939.
1939 THE FUTURE
23 | Keysight | N8480 Series Thermocouple Power Sensors - Data Sheet For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-28-15) www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System