Comprehensive test suite to accelerate functional performance testing of cellular user equipment in a controlled laboratory environment Agilent N5972A Interactive Functional T est Software Technical Overview Optimize UE performance for real-world user scenarios
- Reduce design and validation cycles
- Create individual test sequences
- Develop comprehensive test scripts
- Create automated test plans to stress UE with simultaneous activities
- Measure the impact on UE performance, including battery drain The ever-increasing complexity of cellular devices is driving the need to stress test phones and modems using scenarios that anticipate realistic use cases. Performing this testing, and making any necessary alterations during the design and verification stage prevents the cost of resolution from growing exponentially as the functionality- packed devices progress further downstream. The Agilent Technologies N5972A interactive functional test (IFT) software provides an automated and simplified interface for testing cellular UE under real-world net- work scenarios experienced by end users. This software simultaneously performs functional and parallel testing of call processing, FTP, and SMS features, while monitoring current drain and changing the RF power to the UE. The N5972A provides the added benefit of simulating real-world conditions in a controlled environment, allowing UE designs to be optimized ahead of deployment on a real network.
results in a positive end-user experience. between design and compliance. rather than developing in-house test tools. need to progress rapidly to deployment. Figure 1. Examples of activities to consider for functional test of UE
Figure 2. Interactions of multiple activities changing over time design lifecycle to find defects.
activities you want your device to perform. common programming functions. steps in a stress-test plan. notification of test plan status and results. Figure 3. N5972A IFT software application with 14585A current drain monitoring
drain on the device’s battery. traditional talk time and standby time.
- Direct measurement of battery performance, or battery emulation to power UE
- Log peak and average current and power consumption, with high dynamic range and short time resolution
- Long term data logging to capture battery operating time for comparison with expected values
- Verification of UE low voltage shutdown
Figure 6. Example trace from 14585A battery drain analysis software, annotated with functional events
- Client PC for running IFT
- Server PC supporting required services
- Agilent PXT or 8960 Series 10 wire- less communications test set
- Power supply for UE (optional) IFT software N5972A-1FP interactive functional test software
- Enables use of IFT on a single PC
- Includes software install for server PC including Now SMS, Apache, FileZilla, UDP, and MMS N5972A-5FP IFT automation for Android
- Enables full automation of Android devices from within IFT IMS-SIP network emulator (optional) E6966A-1FP IMS-SIP server emulator
- Enables use of server and remote client on a single PC E6966A-2FP IMS-SIP client emulator
- Client software for a standalone PC (co-resident on same PC as IFT) PC requirements for running IFT server and client Hardware/Operating system
- 1.8 GHz Pentium dual core proces- sor or better
- Windows 7 Professional or Windows 7 Enterprise
- 2 GB RAM
- 2 GB of available hard disk space
- LAN port
- 2 available USB ports
- Audio interface (optional)
- Webcam (optional) Wireless communications test sets
- E6621A PXT with appropriate software applications supporting required technologies
- E5515C/E 8960 Series 10 with appropriate software applications supporting required technologies Battery performance test
- N6705B DC power analyzer with N6781A SMU and 14585A battery drain analysis software
- 66319D DC source with 14565B analysis software Miscellaneous
- Agilent 82357B (or similar) USB/ GPIB interface
- Gigabit LAN router/switch
- LAN cables
- RF cables
- GPIB cables
- UE control (as appropriate)
- UE battery breakout cable (as appropriate) U E B a t t e r y v o l t a g e & c u r r e n t m e t e r i n g R F C o n t r o l i n t e r f a c e N 6 7 0 5 B D C p o w e r a n a l y z e r w i t h N 6 7 8 1 A S M U i n m e a s u r e - o n l y m o d e U E w i t h b a t t e r y O p t i o n a l P C o r i n t e r n e t c o n n e c t i o n f o r r u n n i n g s e r v e r a p p l i c a t i o n s L A N PXT wireless communications test set PC running N5972A IFT software and 14585A battery drain analysis software
Figure 7. Example configuration for functional test with battery drain analysis
www.agilent.com/find/myagilent A personalized view into the information most relevant to you. www.agilent.com www.agilent.com/find/N5972A www.agilent.com/find/PXT www.agilent.com/find/8960 For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3600 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 €/minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus (BP-09-27-13) Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2012-2014 Published in USA, January 29, 2014 5991-0028EN