P a g e Find us at www.keysight.com Page 1 N5700 Series System DC Power Supplies Models: N5741A -49A, N5750A -52A, N5761A -69A, N5770A -72A Family of Affordable Basic System DC Power Supplies

  • 24 models: 750 W and 1500 W output power
  • Up to 600 V and up to 180 A
  • Small high density 1 U package
  • Built-in voltage and current measurement
  • Full protection from over-voltage and over-current
  • 85-265 Vac universal AC input
  • Command compatibility for Sorensen DLM and Xantrex XFR DC supplies
  • LAN, USB, and GPIB interfaces standard
  • Fully compliant to LXI Class C specification The Keysight Technologies, Inc. N5700 Series system DC power supplies give you just the right performance — at just the right price — in a compact (1 U) package. This family of affordable 750 W and 1500 W single-output programmable DC power supplies consists of 24 models for simple DC power applications. They provide stable output power, built -in voltage and current measurement, and output voltage and current from 6 V to 600 V and 1.3 A to 180 A.

above or below it to save valuable rack space. can lock the front panel controls to protect against accidental power-supply parameter changes. Figure 1. Front-panel control knobs and buttons make it easy to use N5700 power supplies. window for sensitive load circuitry. compliant with the LXI Class C specification.

P a g e Find us at www.keysight.com Page 4 Command compatibility The N5700 includes a compatibility command set for the Xantrex XFR series power supplies, the Sorensen DLM series power supplies, and the Keysight 603x series power supplies. This simplifies system integration when converting to the N5700. For a comparison of these products, see application notes:

  • Side-by-side comparison: Keysight N5700 Series System DC Source and Sorensen DLM DC Power Supply, AN 1502-1, 5989-1628EN
  • Side-by-side comparison: Keysight N5700 Series System DC Source and Xantrex XFR AN 1502-2, 5989-1630EN Flexible configuration: connect multiple units in parallel and series Should you need greater output power, the N5700 series power supplies give you the flexibility to connect in parallel up to four similarly rated units for greater output current and connect two similarly rated units in series for greater output voltage (see output terminal isolation information). Analog programming and monitoring The output voltage and current can be programmed from zero to full scale by either an analog volt age 0 to 5 V or 0 to 10 V or by resistances of 0 to 5 kΩ or 0 to 10 kΩ. Universal AC input All N5700 models have universal AC input so they can be automatically operated from any AC mains input voltage worldwide. They can be operated from line voltages of 85 – 265 Vac, 47 to 63 Hz, with no switch to set or fuses to change when you switch from one voltage standard to another. They also provide power factor correction. Rack mounting The rack mount ears and handles are provided standard with every unit. In addition the N5740A rack mount slide kit makes it easy to integrate an N5700 into a test rack by providing all the necessary hardware to rack mount an N5700 series power supply in only 1 U of rack space.

P a g e Find us at www.keysight.com Page 5 Performance specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40 °C. N5741A N5742A N5743A N5744A N5745A N5746A DC output ratings1 Voltage 6 V 8 V 12.5 V 20 V 30 V 40 V Current

100 A 90 A 60 A 38 A 25 A 19 A

Power 600 W 720 W 750 W 760 W 750 W 760 W Output ripple and noise CV p-p2 60 mV 60 mV 60 mV 60 mV 60 mV 60 mV CV rms3 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV Load effect (change from 10% to 90%) Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 25 mA 23 mA 17 mA 12.6 mA 10 mA 8.8 mA Source effect (change from 85-132 VAC input or 170-265 VAC input) Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 12 mA 11 mA 8 mA 5.8 mA 4.5 mA 3.9 mA Programming accuracy1 Voltage 0.05%+ 3 mV 4 mV 6.25 mV 10 mV 15 mV 20 mV Current 0.1%+ 100 mA 90 mA 60 mA 38 mA 25 mA 19 mA Measurement accuracy Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV Current 0.1%+ 300 mA 270 mA 180 mA 114 mA 75 mA 57 mA Load transient recovery time4 Time ≤1.5 ms ≤1.5 ms ≤1.5 ms ≤1 ms ≤1 ms ≤1 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing Output response time (settle to within ±1.0% of the rated output, with a resistive load) Command response time5 55 ms Data readback transfer time6 3 ms Remote sense compensation Volts/load lead 1 V 1 V 1 V 1 V 1.5 V 2 V Over-voltage protection Range 0.5–7.5 V 0.5–10 V 1–15 V 1–24 V 2–36 V 2–44 V Output ripple and noise7 CC rms 200 mA 180 mA 120 mA 76 mA 63 mA 48 mA Programming resolution measurement resolution Current 12 mA 10.8 mA 7.2 mA 4.56 mA 3 mA 2.3 mA Front panel display accuracy (4 digits; ±1 count) Notes: 1. Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage. Minimum current is guaranteed to a maximum of 0.4% of the rated output current. 2. Up to 20 MHz 3. From 5 Hz – 1 MHz 4. Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output 5. Add this to the output response time to obtain the total programming time 6. Time to provide data back to the controller using LAN interface (does not include A/D conversion time) 7. From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)

P a g e Find us at www.keysight.com Page 6 Performance specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40 °C. N5747A N5748A N5749A N5750A N5751A N5752A DC output ratings1 Voltage 60 V 80 V 100 V 150 V 300 V 600 V Power 750 W 760 W 750 W 750 W 750 W 780 W Output ripple and noise CV p-p2 60 mV 60 mV 80 mV 80 mV 100 mV 150 mV CV rms3 8 mV 8 mV 8 mV 8 mV 12 mV 20 mV Load effect (change from 10% to 90%) Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Source effect (change from 85-132 VAC input or 170-265 VAC input) Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Programming accuracy1 Voltage 0.05%+ 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV Measurement accuracy Voltage 0.1%+ 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV Load transient recovery time4 Time ≤1 ms ≤1 ms ≤1 ms ≤2 ms ≤2 ms ≤2 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing Output response time (settle to within ±1.0% of the rated output, with a resistive load) Command response time5 55 ms Data readback transfer time6 3 ms Remote sense compensation Volts/load lead 3 V 4 V 5 V 5 V 5 V 5 V Over-voltage protection Range 5–66 V 5–88 V 5–110 V 5–165 V 5–330 V 5–660 V Accuracy 0.06 V 0.60 V 0.80 V 1 V 1.5 V 3 V Output ripple and noise7 CC rms 38 mA 29 mA 23 mA 18 mA 13 mA 8 m Programming resolution measurement resolution Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV Front panel display accuracy (4 digits; ±1 count) Notes: 1. Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage. Minimum current is guaranteed to a maximum of 0.4% of the rated output current. 2. Up to 20 MHz 3. From 5 Hz – 1 MHz 4. Time for output voltage to recover within 0.5% of its rated outp ut for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output 5. Add this to the output response time to obtain the total programming time 6. Time to provide data back to the controller using LAN interface (d oes not include A/D conversion time) 7. From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)

P a g e Find us at www.keysight.com Page 7 Performance specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40 °C. N5761A N5762A N5763A N5764A N5765A N5766A DC output ratings1 Voltage 6 V 8 V 12.5 V 20 V 30 V 40 V Current 180 A 165 A 120 A 76 A 50 A 38 A Power 1080 W 1320 W 1500 W 1520 W 1500 W 1520 W Output ripple and noise CV p-p2 60 mV 60 mV 60 mV 60 mV 60 mV 60 mV CV rms3 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV Load effect (change from 10% to 90%) Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 41 mA 38 mA 29 mA 20.2 mA 15 mA 12.6 mA Source effect (change from 85-132 VAC input or 170-265 VAC input) Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 20 mA 18.5 mA 14 mA 9.6 mA 7 mA 5.8 mA Programming accuracy1 Voltage 0.05%+ 3 mV 4 mV 6.25 mV 10 mV 15 mV 20 mV Current 0.1%+ 180 mA 165 mA 120 mA 76 mA 50 mA 38 mA Measurement accuracy Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV Current 0.1%+ 540 mA 495 mA 360 mA 228 mA 150 mA 114 mA Load transient recovery time4 Time ≤1.5 ms ≤1.5 ms ≤1.5 ms ≤1 ms ≤1 ms ≤1 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing Output response time (settle to within ±1.0% of the rated output, with a resistive load) Command response time5 55 ms Data readback transfer time6 3 ms Remote sense compensation Volts/load lead 1 V 1 V 1 V 1 V 1.5 V 2 V Over-voltage protection Range 0.5–7.5 V 0.5–10 V 1–15 V 1–24 V 2–36 V 2–44 V Output ripple and noise7 CC rms 360 mA 330 mA 240 mA 152 mA 125 mA 95 mA Programming resolution measurement resolution Front panel display accuracy (4 digits; ±1 count) Notes: 1. Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage. Minimum current is guaranteed to a maximum of 0.4% of the rated output current. 2. Up to 20 MHz 3. From 5 Hz – 1 MHz 4. Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output 5. Add this to the output response time to obtain the tot al programming time 6. Time to provide data back to the controller using LAN interface (does not include A/D conversion time) 7. From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage )

P a g e Find us at www.keysight.com Page 8 Performance specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40 °C. N5767A N5768A N5769A N5770A N5771A N5772A DC output ratings1 Voltage 60 V 80 V 100 V 150 V 300 V 600 V Current 25 A 19 A 15 A 10 A 5 A 2.6 A Power 1500 W 1520 W 1500 W 1500 W 1500 W 1560 W Output ripple and noise CV p-p2 60 mV 80 mV 80 mV 100 mV 150 mV 300 mV CV rms3 8 mV 8 mV 8 mV 12 mV 20 mV 60 mV Load effect (change from 10% to 90%) Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Current 10 mA 8.8 mA 8 mA 7 mA 6 mA 5.5 mA Source effect (change from 85-132 VAC input or 170-265 VAC input) Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Programming accuracy1 Voltage 0.05%+ 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV Current 0.1%+ 25 mA 19 mA 15 mA 10 mA 5 mA 2.6 mA Measurement accuracy Voltage 0.1%+ 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV Current 0.1%+ 75 mA 57 mA 45 mA 30 mA 15 mA 7.8 mA Load transient recovery time4 Time ≤1 ms ≤1 ms ≤1 ms ≤2 ms ≤2 ms ≤2 ms Supplemental Characteristics Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing Output response time (settle to within ±1.0% of the rated output, with a resistive load) Command response time5 55 ms Data readback transfer time6 3 ms Remote sense compensation Volts/load lead 3 V 4 V 5 V 5 V 5 V 5 V Over-voltage protection Range 5–66 V 5–88 V 5–110 V 5–165 V 5–330 V 5–660 V Accuracy 0.60 V 0.80 V 1 V 1.5 V 3 V 6 V Output ripple and noise7 CC rms 75 mA 57 mA 45 mA 35 mA 25 mA 12 m Programming resolution measurement resolution Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV Front panel display accuracy (4 digits; ±1 count) Notes: 1. Minimum voltage is guaranteed to a maximum of 0.2% of the rated output voltage. Minimum current is guaranteed to a maximum of 0.4% of the rated output current. 2. Up to 20 MHz 3. From 5 Hz – 1 MHz 4. Time for output voltage to recover within 0.5% of its rated outp ut for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output 5. Add this to the output re sponse time to obtain the total programming time 6. Time to provide data back to the controller using LAN interface (d oes not include A/D conversion time) 7. From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage)

P a g e Find us at www.keysight.com Page 9 Supplemental Characteristics for All Model Numbers Series and parallel capability Parallel operation Up to 4 units can be connected in primary/secondary mode Series operation Up to 2 units can be connected in series Output terminal isolation

6 V to 60 V units

No output terminal may be more than ±60 VDC from any other terminal or chassis ground

80 V to 600 V units

No output terminal may be more than ±600 VDC from any other terminal or ch assis ground Store-recall states Volatile memory locations: 16 Analog programming (of output voltage and current) Input signal Selectable; 0 to 5 V / 0 to 10 V full scale Input impedance Selectable; 0 to 5 kΩ / 0 to 10 kΩ full scale WARNING Shock Hazard

  • For models up to 60 VDC rated output, no point on the output shall be more than ± 60 VDC above or below chassis ground.
  • For models greater than 60 VDC rated output, no point on the Positive output shall be more than ± 600 VDC above or below chassis ground.
  • For models greater than 60 VDC rated output, no point on the Negative output shall be more than ± 400 VDC above or below chassis ground.

P a g e Find us at www.keysight.com Page 10 Interface capabilities GPIB SCPI – 1993, IEEE 488.2 compliant interface USB 2.0 Requires Keysight I/O library version L.01.01 10/100 LAN Requires Keysight I/O library version L.01.01 Web server Built-in Web server requires Internet Explorer 5+ or Netscape 6.2+ Environmental conditions Environment Indoor use, installation category II (AC input), pollution degree 2 Operating temperature 0°C to 40°C @ 100% load Storage temperature –20°C to 70°C Operating humidity 30% to 90% relative humidity (no condensation) Storage humidity 10% to 95% relative humidity (no condensation) Altitude

  • Up to 3000 meters. Derate the output current by 2%/100 m above 2000 m.
  • Derate the maximum ambient temperature by 1 °C/100 m above 2000 m. Regulatory compliance EMC
  • European EMC directive 89/336/EEC for Class A products
  • Australian C- Tick mark
  • This ISM device complies with Canadian ICES-001.
  • Cet appareil ISM est conforme à la norme NMB-001 du Canada.

P a g e Find us at www.keysight.com Page 11 Safety

  • European Low Voltage Directive 73/23/EEC
  • US and Canadian safety standards
  • Any LEDs used in this product are Class 1 as per IEC 825-1 Acoustic noise declaration Emission directive:
  • Sound pressure Lp <70 dB(A), At operator position, *Normal operation, *According to EN 27779 (Type Test).
  • Schalldruckpegel Lp <70 dB(A) *Am Arbeitsplatz, *Normaler Betrieb, *Nach EN 27779 (Typprüfung). AC input Nominal input 100 – 240 VAC; 50/60 Hz Input current 750 W

10.5 A @ 100 VAC nominal;

5 A @ 200 VAC nominal

21 A @ 100 VAC nominal;

11 A @ 200 VAC nominal

85 – 265 VAC; 47 – 63 Hz. Power factor 0.99 at nominal input and rated output power Efficiency 76% – 87% for 750 W units; 77% – 88% for 1500 W units Inrush current <25 A for 750 W units; <50 A for 1500 W units Dimensions (excluding connectors, and handles) Height 43.6 mm (1.72 in) Width 422.8 mm (16.65 in) Depth 432.8 mm (17.04 in)

P a g e Find us at www.keysight.com Page 12 Weight 750 W 7 Kg (15.4 lbs.) 1500 W 8.5 Kg (18.7 lbs.) Outline Diagram DC output Bus-bar detail

6 V to 60 V

1500 W models

P a g e Find us at www.keysight.com Page 13 Front and Rear Panel Detail Front Panel (All Models) Rear Panel* (6 V to 60 V, 1500 W Models) (80 V to 600 V, 750 W Models) (6 V to 60 V, 750 W Models) (80 V to 600 V, 1500 W Models) = air flow (in front, out rear)

P a g e Find us at www.keysight.com Page 14

Ordering Information

750 W Models

N5741A System DC Power Supply 6 V, 100 A, 600 W N5742A System DC Power Supply 8 V, 90 A, 720 W N5743A System DC Power Supply 12.5 V, 60 A, 750 W N5744A System DC Power Supply 20 V, 38 A, 760 W N5745A System DC Power Supply 30 V, 25 A, 750 W N5746A System DC Power Supply 40 V, 19 A, 760 W N5747A System DC Power Supply 60 V, 12.5 A, 750 W N5748A System DC Power Supply 80 V, 9.5 A, 760 W N5749A System DC Power Supply 100 V, 7.5 A, 750 W N5750A System DC Power Supply 150 V, 5 A, 750 W N5751A System DC Power Supply 300 V, 2.5 A, 750 W N5752A System DC Power Supply 600 V, 1.3 A, 780 W N5761A System DC Power Supply 6 V, 180 A, 1080 W N5762A System DC Power Supply 8 V, 165 A, 1320 W N5763A System DC Power Supply 12.5 V, 120 A, 1500 W N5764A System DC Power Supply 20 V, 76 A, 1520 W N5765A System DC Power Supply 30 V, 50 A, 1500 W N5766A System DC Power Supply 40 V, 38 A, 1520 W N5767A System DC Power Supply 60 V, 25 A, 1500 W N5768A System DC Power Supply 80 V, 19 A, 1520 W N5769A System DC Power Supply 100 V, 15 A, 1500 W N5770A System DC Power Supply 150 V, 10 A, 1500 W N5771A System DC Power Supply 300 V, 5 A, 1500 W N5772A System DC Power Supply 600 V, 2.6 A, 1560 W

P a g e Find us at www.keysight.com Page 15 Options Opt 900 Power Cord, United Kingdom Opt 902 Power Cord, Europe Opt 903 Power Cord, USA, Canada Opt 918 Power Cord, Japan Opt 922 Power Cord, China Opt 861 Unterminated Power Cord, USA, Canada, Japan, China, Other Opt 862 Harmonized Unterminated Power Cord, Europe Accessories N5740A Rack Mount Slide Kit (required for rack mounting; standard system 11 rack-mounting hardware will not work)

P a g e Find us at www.keysight.com Page 16 Learn more at: www.keysight.com For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus This information is subject to change without notice. © Keysight Technologies, 2017 -2021, Published in USA, January 27, 2021 , 59 89-1330 EN Related Literature These application notes will help you compare Keysight system DC sources with power supplies from other manufacturers:

  • Side-by-Side Comparison: Keysight N5700 Series System DC Source and Sorensen DLM DC Power Supply, AN 1502-1, 5989-1628EN https://www.keysight.com/my/en/assets/7018-01257/application-notes/5989-1628.pdf
  • How to Convert from a Sorensen DLM to an Keysight N5700, AN 1503-1, 5989-1629EN https://www.keysight.com/my/en/assets/7018-01258/application-notes/5989-1629.pdf
  • Side-by-Side Comparison: Keysight N5700 Series System DC Source and Xantrex XFR System Power Supplies, AN 1502-2, 5989-1630EN https://www.keysight.com/my/en/assets/7018-01259/application-notes/5989-1630.pdf
  • How to Convert from a Xantrex XFR to an Keysight N5700, AN 1503-2, 5989-1631EN https://www.keysight.com/my/en/assets/7018-01260/application-notes/5989-1631.pdf
  • Trends in Medium Power (~1 kW) DC Power Supplies, 5989-1331EN https://www.keysight.com/my/en/assets/7018-01236/application-notes/5989-1331.pdf Keysight’s IO Libraries Suite ships with the N5700 to help you quickly establish an error-free connection between your PC and instruments - regardless of the vendor. It provides robust instrument control and works with the software development environment you choose. For additional description of Keysight’s IO Libraries Suite features and installation requirements, please go to http://www.keysight.com/find/iosuite