CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes Data Sheet
Debug the signal integrity of your CAN and LIN designs faster The Keysight Technologies inc. IniniiVision Series digital storage osc illoscopes (DSOs) and mixed signal oscilloscopes (MSOs) offer integrated serial triggering an d hardware-accelerated protocol decoding solutions that give you the tools you need to eficiently and effec tively debug your embedded automotive or industrial equipment designs. Option AMS provid es extended CAN and LIN triggering and decoding in all four-channel DSOs and MSOs. Features: – Integrated serial triggering for testing your CAN and LIN serial buses – Real-time protocol decode update rates using hardware-accelerated protocol decoding –Precision differential active probes –Mixed-signal measurements across analog sensors, serial buses, and di gital ECU signals – Compatible with Segmented Memory option to capture and decode up to 2000 consecutive frames –Automatic “Search and Navgations” (7000B only)
07 | Keysight | CAN/LIN Measurements (Option AMS) for IniniiVision Series Oscilloscopes - Data Sheet CAN specifications/characteristics (N5424A or Option AMS) CAN source Analog channels 1, 2, 3, or 4 Baud rates 10 kbps up to 1 Mbps (user-selectable) Triggering Start-of-frame (SOF) 1 Remote frame ID (RMT) Data frame ID (~RMT) Remote or data frame ID Data frame ID and data Error frame ID length: 11 bits or 29 bits (extended) Color-coded, hardware-accelerated Frame ID (hex digits in yellow) decode Remote frame (RMT in green) Data length code (DLC in blue) Data bytes (hex digits in white) CRC (hex digits in blue = valid, hex digits in red = error) Error frame (bi-level bus trace and ERR message in red) Overload frame (“OVRLD” in blue) Idle bus (high bus trace in white) Active bus (bi-level bus trace in dark-blue) Totalize function Total frames Total overload frames Total Error frames Bus utilization
1 Standard CAN triggering in all Keysight 6000 Series oscilloscopes
LIN specifications/characteristics (N5424A or Option AMS) LIN source Analog channels 1, 2, 3, or 4 Logic channels D0 – D15 LIN standards LIN 1.3 or LIN 2.0 Signal types LIN single-ended Tx Rx Baud rates 2400 bps, 9600 bps, 10.4 kbs, 19.2 kbs, 115.2 kbs or 625 kbs (user-selectable) Triggering Sync break 1 Frame ID (0X00 HEX to 0X3FHEX) Frame ID AND Data Color-coded, hardware-accelerated Frame ID (6-bit hex digits in yellow) decode Frame ID and optional parity bits (8-bit hex digits in yellow) Data bytes (hex digits in white) Lin 2.0 check sum (hex digits in white) Lin 1.3 check sum (hex digits in blue = valid, hex digits in red = error) Sync error (“SYNC” in red) T Header-Max (“THM” in red) T Frame-max (“TFM” in red) Parity error (“PAR” in red) LIN 1.3 wake-up error (“WUP” in red) Lin 1.3 idle bus (high bus trace in white) Active bus (bi-level bus trace in dark-blue)
1 Standard LIN triggering in all Keysight 6000 Series oscilloscopes
08 | Keysight | CAN/LIN Measurements (Option AMS) for IniniiVision Series Oscilloscopes - Data Sheet
Ordering information
Option AMS (CAN/LIN) is compatible only with 4-channel DSOs and 4+16 channel MS O models in the IniniiVision Series oscilloscopes, including the 5000, 6000, and 700 0 Series scopes. If you already own a 4-channel IniniiVision Series DSO or MSO and would like to upg rade your scope to support CAN and LIN measurements, order the N5424A after-purchase upg rade kit. Factory-installed User-installed option number option number Description Option AMS N5424A CAN/LIN triggering and decode (4 and 4+16 channel models only) Option FLX N5432C FlexRay triggering and decode (4 and 4+16 channel models only) Option LSS N5423A I 2C/SPI triggering and decode (4 and 4+16 channel models only) Option 232 N5457A RS-232/UART triggering and decode (4 and 4+16 channel models only) Option SND N5468A I2S triggering and decode (4 and 4+16 channel models only) Option SGM N5454A Segmented Memory Option LMT N5455A Mask testing N2791A 25-MHz differential active probe N2792A 200-MHz differential active probe 0960-2926 CAN/FlaxRay DB9 Probe Head (compatible with N2791A and N2792A) 1130A InfiniiMax 1.5-GHz differential active probe (probe heads must be ordered separately) N5450A Extreme Temperature Cable Extension Kit for 1130A InfiniiMax probes Note that additional options and accessories are available for Keysight InfiniiVision Series oscilloscopes. Refer to the appropriate 5000, 6000, or 7000 Series data sheet for ordering information about these additional options and accessories, as well as ordering information for specific oscilloscope models.
09 | Keysight | CAN/LIN Measurements (Option AMS) for IniniiVision Series Oscilloscopes - Data Sheet Related literature Publication title Publication type Publication number Keysight InfiniiVision 7000 Series Oscilloscopes Data sheet 5990-4769EN Evaluating Oscilloscope Segmented Memory for Serial Bus Applications Application note 5990-5817EN Using a Keysight InfiniiVision MSO to Debug an Automotive CAN Bus Application note 5989-5049EN Evaluating Oscilloscopes for Best Waveform Update Rate Application note 5989-7885EN Evaluating Oscilloscopes to Debug Mixed-Signal Designs Application note 5989-3702EN Evaluating Oscilloscope Bandwidths for your Applications Application note 5989-5733EN Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity Application note 5989-5732EN Evaluating Oscilloscope Vertical Noise Characteristics Application note 5989-3020EN Extending the Range of Keysight InfiniiMax Probes Application note 5989-7587EN Product Web site For the most up-to-date and complete application and product informatio n, please visit our product Web site at: www.keysight.com/find/scopes
10 | Keysight | CAN/LIN Measurements (Option AMS) for IniniiVision Series Oscilloscopes - Data Sheet Keysight Technologies Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful app lications
www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/CAN-LIN For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Paciic Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-10-14) 11 | Keysight | CAN/LIN Measurements (Option AMS) for IniniiVision Series Oscilloscopes - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2010 - 2014 Published in USA, July 31, 2014 5989-6220EN www.keysight.com