UXG X-Series Agile Signal Generator, Modified Version

10 MHz to 20 or 40 GHz

02 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Table of Contents

03 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Definitions and Conditions Specification (spec): represents warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the operating temperature range of 0 to 55 °C, unless otherwise stated, and after a 1 hour warm-up period. The specifications include measurement uncertainty. Data represented in this document are specifications unless otherwise noted. Typical (typ): describes additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 80% of the units exhibit with a 95% confidence level at room temperature (approximately 25 °C). Typical performance does not include measurement uncertainty. Nominal (nom): describes the expected mean or average performance, or an attribute whose performance is by design, such as the 50 Ω connector. This data is not warranted and is measured at room temperature (approximately 25 °C). Measured (meas): describes an attribute measured during the design phase for purposes of communicating expected performance, such as amplitude drift vs. time. This data is not warranted and is measured at room temperature (approximately 25 °C). All of the above apply when using the instrument in its default settings unless otherwise stated. This data sheet provides a summary of the key performance parameters for N5191A modified UXG signal generators. All options referenced in this data sheet are described in the N5191A modified UXG configuration guide (5992-1116EN).

04 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Specifications Frequency Range Specified range Tunable range Option 52E 10 MHz to 20 GHz 10 MHz to 21.5 GHz Option 54E 10 MHz to 40 GHz 10 MHz to 40 GHz CW frequency resolution Standard 10 kHz Option FR1 0.001 Hz Frequency switching modes Phase continuous switching Minimizes phase changes and spectral splatter when transitioning to a new frequency within a band. Phase coherent switching When returning to a prior frequency, returns to the prior phase trajectory at that frequency, assuming the same setup conditions. Some temporary amplitude and phase changes may occur during transitions. Phase offset Adjustable in 0.1° increments (nom) Accuracy Accuracy is equivalent to the internal or external frequency reference in use. Choices are the internal timebase reference oscillator, the external reference input, the system sync input, and the 6 GHz input. Internal timebase reference oscillator Initial calibration accuracy ± 5 × 10-8 Aging rate 1 ± 3 × 10-8/year or ± 2.5 x 10 -10/day after 30 days Temperature effects ± 4.5 × 10-9 (nom) from 0 to 55 °C Electronic frequency control (EFC) sensitivity –0.04 ppm/V (nom) from –10 V to +10 V External 10 MHz reference input Frequency 10 MHz Modes Manually or automatically selected Lock range ± 1.0 ppm (nom) Input amplitude 6 dBm ± 6 dB (nom). To optimize phase noise use 6 dBm ± 2 dB (nom). Input impedance 50 Ω (nom) Other reference choices System sync in/out See the Synchronization Section

6 GHz in/out See the Synchronization Section

Reference output (10/100 MHz output) Frequency 10 MHz or 100 MHz, user selectable Amplitude 7 dBm (nom) into 50 Ω load 1. Not verified by Keysight N7800A TME Calibration and Adjustment Software. Daily aging rate may be verified as a supplementary chargeable service, on request.

05 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Frequency bands (Frequency Mode A, default) Frequency Bands (Frequency Mode A, Default) Frequency (GHz) Region A0 Region A1 Region A2 Region A3 Region A4 Region A5 Region A6 Region A7 Region A8 Region A9 (N=1) (N=1) (N=2) (N=4) (N=8) (N=16)1 (N=16) (N=32) (N=32) (N=32)Opt. 54E Opt. 54E Opt. 54E Opt. 54E Legend Normal CW Band Extended Band for Modulation Available through Band Hold Nor mal CW Band Limits Extended Band Limits f or Modulation 10 − 13.5 MHz

10 MHz

12.1 − 20.4 MHz

12.8 MHz

18.4 − 30.9 MHz

19.4 MHz

27.8 − 46.9 MHz

29.4 MHz

42.2 − 71 MHz

44.5 MHz

63.9 − 108 MHz

67.5 MHz

96.9 − 163 MHz

102 MHz

147 − 247 MHz

155 MHz

223 − 375 MHz

235 MHz

338 − 568 MHz

356 MHz

512 − 862 MHz

540 MHz

775 − 1310 MHz

818 MHz

42.2 − 1980 MHz

1240 MHz

1.35 − 1.72 GHz

1.43 GHz

1.55 − 1.98 GHz

1.64 GHz

1.78 − 2.27 GHz

1.88 GHz

2.05 − 2.61 GHz

2.16 GHz

2.35 − 3 GHz

2.48 GHz

2.7 − 3.45 GHz

2.85 GHz

3.1 − 3.96 GHz

3.27 GHz

3.56 − 4.55 GHz

3.76 GHz

4.09 − 5.22 GHz

4.32 GHz

4.7 − 6 GHz

4.96 GHz

5.4 − 6.89 GHz

5.7 GHz

6.2 − 7.92 GHz

6.55 GHz

7.13 − 9.09 GHz

7.52 GHz

8.18 − 10.4 GHz

8.64 GHz

9.4 − 12 GHz

9.92 GHz

10.8 − 13.8 GHz

11.4 GHz

12.4 − 15.83 GHz

13.1 GHz

14.3 − 18.2 GHz

15 GHz

16.4 − 20.9 GHz

17.3 GHz

18.8 − 21.5 GHz

19.8 GHz

19.8 − 24 GHz

20.55 GHz

21.6 − 26.6 GHz

22.8 GHz

25.1 − 31.6 GHz

25.6 GHz

28.6 − 32.7 GHz

30.1 GHz

31.5 − 36.4 GHz

32 GHz

32.8 − 40 GHz

34.6 GHz

  1. In Option 52E, the 18.8-21.5 GHz band behaves like it is part of Region A5. In Option 54E, the 18.8-21.5 GHz band behaves like it is part of Region A6.

06 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Frequency bands (Frequency Mode B) Frequency Bands (Frequency Mode B) Frequency (GHz) Region A0 Region A1 Region A2 Region A3 Region A4 Region A5 Region A6 Region A7 Region A8 Region A9 (N=1) (N=1) (N=2) (N=4) (N=8) (N=16)1 (N=16) (N=32) (N=32) (N=32)Opt. 54E Opt. 54E Opt. 54E Opt. 54E Legend Normal CW Band Extended Band for Modulation Available through Band Hold Identical to Frequency Mode A Nor mal CW Band Limits Extended Band Limits f or Modulation 10 − 13.5 MHz 12.1 − 20.4 MHz 18.4 − 30.9 MHz 27.8 − 46.9 MHz 42.2 − 1980 MHz 338 − 2610 MHz 2.35 − 3 GHz 2.7 − 3.45 GHz 3.1 − 3.96 GHz 3.56 − 4.55 GHz 4.09 − 5.22 GHz 4.7 − 6 GHz 5.4 − 6.89 GHz 6.2 − 7.92 GHz 7.13 − 9.09 GHz 8.18 − 10.4 GHz 9.4 − 12 GHz 10.8 − 13.8 GHz 12.4 − 15.83 GHz 14.3 − 18.2 GHz 16.4 − 20.9 GHz 18.8 − 21.5 GHz 19.8 − 24 GHz 21.6 − 26.6 GHz 25.1 − 31.6 GHz 28.6 − 32.7 GHz 31.5 − 36.4 GHz 32.8 − 40 GHz

  1. In Option 52E, the 18.8-21.5 GHz band behaves like it is part of Region A5. In Option 54E, the 18.8-21.5 GHz band behaves like it is part of Region A6.

07 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Frequency band overview Default bands (Mode A) Provide lowest harmonics and spurious signals. 42.2 to 1980 MHz band (Mode B) Provides wider bandwidth at low frequencies for wider chirps, wider FM, and better pulse shape. 338 to 2610 MHz band (Mode B) Provides wider bandwidth at low frequencies for wider chirps, wider FM, and better pulse shape. Reduces pulse video feedthrough. Power Dual attenuator specified frequency range (Option AT1) Option 52E Option 54E Electronic agile attenuator 10 MHz to 20 GHz 10 MHz to < 25.6 GHz Mechanical step attenuator 10 MHz to 20 GHz 10 MHz to 40 GHz Dual attenuator step size (Option AT1) Electronic agile attenuator 0 dB to 70 dB in 5 dB steps, for frequencies < 25.6 GHz, or bypassed Mechanical step attenuator 0 dB to 85 dB in 5 dB steps, for frequencies up to 40 GHz Maximum output power (Option 52E) Frequency Standard Option AT1 Electronic attenuator bypassed Option AT1 Electronic attenuator inline

10 MHz to 13 GHz 10 dBm 10 dBm –1 dBm

13 GHz to 18 GHz 10 dBm 10 dBm –4 dBm > 18 GHz to 20 GHz 10 dBm 10 dBm –6 dBm Maximum output power (Option 54E) Frequency Standard Option AT1 Electronic attenuator bypassed Option AT1 Electronic attenuator inline

10 MHz to 13 GHz 10 dBm 8 dBm –3 dBm

13 GHz to 18 GHz 10 dBm 8 dBm –6 dBm > 18 GHz to 20.55 GHz 7 dBm 6 dBm –10 dBm > 20.55 GHz to < 25.6 GHz 10 dBm 10 dBm –7 dBm

25.6 GHz to 32 GHz 7 dBm 6 dBm n/a

32 GHz to 40 GHz 7 dBm 7 dBm n/a Measured maximum output power (Opt 52E) Frequency (GHz) Power (dBm) 05 10 15 20 −15 −10 Without option AT1 Option AT1 with electronic attenuator bypassed Option AT1 with electronic attenuator inline

08 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Measured maximum output power (Opt 54E) Frequency (GHz) Power (dBm) 05 10 15 20 25 30 35 40 −15 −10 Without option AT1 Option AT1 with electronic attenuator bypassed Option AT1 with electronic attenuator inline Minimum settable output power Frequency Standard Option AT1 Electronic attenuator bypassed Option AT1 Electronic attenuator inline

10 MHz to 13 GHz 0 dB (nom) 20 dB (nom) 90 dB (nom)

13 GHz to 20 GHz 0 dB (nom) 20 dB (nom) 90 dB (nom) > 20 GHz to < 25.6 GHz (Option 54E) 0 dB (nom) 10 dB (nom) 80 dB (nom)

25.6 GHz to 36 GHz (Option 54E) 0 dB (nom) 10 dB (nom) n/a

36 GHz to 40 GHz (Option 54E) 0 dB (nom) 10 dB (nom) n/a Agile power range Frequency Standard Option AT1 Electronic attenuator bypassed Option AT1 Electronic attenuator inline Option 52E

10 Hz to 13 GHz

13 to 20 GHz 20 dB (nom) 20 dB (nom) 20 dB (nom) 20 dB (nom) 90 dB (nom) 90 dB (nom) Option 54E
13 to 18 GHz > 18 to 20.55 GHz > 20.55 to < 25.6 GHz > 25.6 GHz to 40 GHz 20 dB (nom) 20 dB (nom) 17 dB (nom) 20 dB (nom) 17 dB (nom) 20 dB (nom) 20 dB (nom) 20 dB (nom) 10 dB (nom) 10 dB (nom) 90 dB (nom) 90 dB (nom) 90 dB (nom) 80 dB (nom) n/a Leveling modes ALC on Internal power leveling ALC off No power leveling ALC off with power alignment Power alignment is a routine that improves level accuracy with ALC off. It aligns the power level with ALC off to match the power level with ALC on at a customer specified power level. It should be run at regular intervals and whenever the operating temperature changes ± 5 °C from the alignment temperature. RF Gating Turns RF power on/off with external trigger

09 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Level accuracy (Option 52E) Specifications apply for CW signals that do not exceed the maximum specified power. For instruments with Option 1ED Type-N connectors, specifications apply below 18 GHz and performance is typically degraded 0.2 dB above 18 GHz. Output power (Standard) ALC on ALC off 10 dBm to 0 dBm ± 1.4 dB (typ) ± 2.0 dB (typ) Output power (Option AT1) Mechanical attenuator Electronic attenuator ALC on ALC off 10 to 2 dBm 0 dB Bypass ± 1.5 dB ± 2.0 dB < 2 to –10 dBm 0 dB Bypass ± 1.6 dB (typ) ± 2.5 dB (typ) 10 to –75 dBm Auto Bypass ± 1.5 dB ± 2.0 dB –3 to –65 dBm 0 dB Inline ± 1.5 dB ± 2.0 dB < –65 to –90 dBm 0 dB Inline ± 2.0 dB ± 2.5 dB 5 to –10 dBm Auto Auto ± 1.5 dB ± 2.0 dB < –10 to –80 dBm Auto Auto ± 1.6 dB ± 2.5 dB Level accuracy (Option 54E, frequency ≤ 20 GHz) Specifications apply for CW signals that do not exceed the maximum specified power. Output power (Standard) ALC on ALC off 10 dBm to 0 dBm ± 1.4 dB (typ) ± 2.0 dB (typ) Output power (Option AT1) Mechanical attenuator Electronic attenuator ALC on ALC off 10 to 0 dBm 0 dB Bypass ± 1.5 dB ± 2.0 dB < 0 to –10 dBm 0 dB Bypass ± 1.6 dB (typ) ± 2.5 dB (typ) 10 to –75 dBm Auto Bypass ± 1.5 dB ± 2.0 dB –15 to –65 dBm 0 dB Inline ± 1.5 dB ± 2.0 dB < –65 to –90 dBm 0 dB Inline ± 2.0 dB ± 2.5 dB 5 to -10 dBm Auto Auto ± 1.5 dB ± 2.0 dB < –10 to –80 dBm Auto Auto ± 1.6 dB ± 2.5 dB Level accuracy (Option 54E, frequency > 20 GHz) Specifications apply for CW signals that do not exceed the maximum specified power. Output power (Standard) ALC on ALC off 10 dBm to 0 dBm ± 1.4 dB (typ) ± 6.5 dB (typ) Output power (Option AT1) Mechanical attenuator Electronic attenuator ALC on ALC off 10 to 0 dBm 0 dB Bypass ± 1.8 dB ± 6.5 dB < 0 to –10 dBm 0 dB Bypass ± 1.6 dB (typ) ± 7.0 dB (typ) 10 to –50 dBm Auto Bypass ± 1.8 dB ± 6.5 dB < –50 to –75 dBm Auto Bypass ± 2.2 dB ± 6.5 dB –15 to –65 dBm 0 dB Inline (< 25.6 GHz) ± 2.0 dB ± 6.5 dB 5 to –10 dBm Auto Auto (< 25.6 GHz) ± 2.0 dB ± 6.5 dB < –10 to –80 dBm Auto Auto (< 25.6 GHz) ± 2.6 dB ± 6.5 dB Agile power linearity (frequency ≤ 20 GHz with Option AT1) Measured relative to –5 dBm for Option 52E and relative to –15 dBm for Option 54E with the mechanical step attenuator set to 0 dB and the electronic attenuator inline. 10 MHz to 13 GHz ± 0.4 dB (typ) for relative power from 0 to –75 dB > 13 GHz to 20 GHz ± 0.5 dB (typ) for relative power from 0 to –75 dB Agile power linearity (frequency > 20 GHz with Options 54E and AT1) Measured relative to –15 dBm with the mechanical step attenuator set to 0 dB and the electronic attenuator inline. > 20 GHz to < 25.6 GHz ± 1.8 dB (typ) for relative power from 0 to –65 dB

25.6 GHz to 40 GHz n/a

10 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Switching speed Agile switching modes Fast CW Switching Mode The fast control port (Options CC1 or CC2) provides agile switching of CW frequency at a constant amplitude with the lowest latency. Normal Mode The fast control port (Option CC1) provides agile switching of frequency, phase, amplitude, pulse modulation, frequency modulation, phase modulation, and chirp. Option CC2 provides agile switching of frequency only. List Mode Internal list memory and a hardware trigger provide agile switching of frequency, phase, amplitude, pulse modula - tion, frequency modulation, phase modulation, and chirp. Resolution 0.01 dB Temperature stability ALC on and frequency ≤ 20 GHz ± 0.02 dB/°C (typ) ALC on and frequency > 20 GHz ± 0.04 dB/°C (typ) ALC off and frequency ≤ 20 GHz ± 0.07 dB/°C (typ) ALC off and frequency > 20 GHz ± 0.15 dB/°C (typ) Output impedance 50 Ω (nom) SWR (meas) without Option AT1 Frequency Option 52E with 1ED Option 54E 10 MHz to 1 GHz 1.4 : 1 1.4 : 1 > 1 GHz to 2 GHz 1.4 : 1 1.5 : 1 > 2 GHz to 18 GHz 1.7 : 1 2 : 1 > 18 GHz to 20 GHz 1.9 : 1 2 : 1 > 20 GHz to 40 GHz n/a 3 : 1 SWR (meas) with Option AT1, electronic attenuator bypassed, mechanical attenuator = 0 dB Frequency Option 52E without 1ED Option 52E with 1ED Option 54E 10 MHz to 1 GHz 1.4 : 1 1.4 : 1 1.4 : 1 > 1 GHz to 2 GHz 1.4 : 1 1.4 : 1 1.5 : 1 > 2 GHz to 18 GHz 1.7 : 1 1.7 : 1 2 : 1 > 18 GHz to 20 GHz 1.8 : 1 1.8 : 1 2 : 1 > 20 GHz to 40 GHz n/a n/a 2 : 1 SWR (meas) with Option AT1, electronic attenuator bypassed, mechanical attenuator > 0 dB Frequency Option 52E without 1ED Option 52E with 1ED Option 54E 10 MHz to 1 GHz 1.2 : 1 1.2 : 1 1.2 : 1 > 1 GHz to 2 GHz 1.2 : 1 1.2 : 1 1.2 : 1 > 2 GHz to 18 GHz 1.5 : 1 1.5 : 1 1.4 : 1 > 18 GHz to 20 GHz 1.5 : 1 1.5 : 1 1.4 : 1 > 20 GHz to 40 GHz n/a n/a 1.5 : 1 SWR (meas) with Option AT1, electronic attenuator inline Frequency Option 52E without 1ED Option 52E with 1ED Option 54E 10 MHz to 1 GHz 1.3 : 1 1.3 : 1 1.3 : 1 > 1 GHz to 2 GHz 1.3 : 1 1.3 : 1 1.3 : 1 > 2 GHz to 18 GHz 1.7 : 1 1.7 : 1 1.6 : 1 > 18 GHz to 20 GHz 1.7 : 1 1.7 : 1 1.6 : 1 > 20 GHz to 40 GHz n/a n/a 1.8 : 1 Maximum reverse power 1/2 Watt, 0 VDC

11 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Frequency transition types Type 1 A frequency change in which the initial frequency and final frequency are in the same band per the frequency band diagrams in the frequency section, but not in region A0. Type 2 A frequency change in which the initial frequency and final frequency are in the same region per the frequency band diagrams in the frequency section, but not in region A0. Type 3 A frequency change in which the initial frequency and final frequency are in regions A1 through A5 per the frequency band diagrams in the frequency section. Type 4 A frequency change in which the initial frequency and final frequency are in regions A1 through A9 per the frequency band diagrams in the frequency section. RF transition speed For frequency and phase transitions at a fixed power level, with ALC off and the electronic attenuator bypassed, for frequencies < 32 GHz. Measured from the first phase change of more than 0.1 radians that occurs after the input trigger, and measured to RF phase settled. Applies to Normal Mode or List Mode, not Fast CW Switching Mode. Transition type Standard Option SS3 (10 MHz to 6.89 GHz) Type 1 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 50 ns (typ) CW switching speed for Fast CW Switching Mode Update rate - measured from output strobe to RF phase and amplitude settled at a fixed power level with ALC off. Transition type Standard Option SS3 (10 MHz to 6.89 GHz) Type 1, 2 or 3 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 240 ns Type 4 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 30 μs Latency - measured from input trigger to RF phase and amplitude settled at a fixed power level with ALC off. Transition type Standard Option SS3 (10 MHz to 6.89 GHz) Type 1, 2 or 3 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 370 ns Type 4 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 30 μs

12 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Switching speed for Normal or List Mode 1 Update rate - measured from pulse sync out or list point start to RF phase and amplitude settled with ALC off. With Option AT1, includes amplitude changes over the agile power range. Transition type Standard Option SS3 (10 MHz to 6.89 GHz) Type 1, 2, or 3 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 180 ns Type 4 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 30 μs Latency - measured from input trigger to RF phase and amplitude settled with ALC off. With Option AT1, includes amplitude changes over the agile power range. Transition type Standard Option SS3 (10 MHz to 6.89 GHz) Type 1, 2 or 3 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 700 ns Type 4 100 μs (10 MHz to 31.6 GHz) 500 us (> 31.6 GHz to 40 GHz) 30 μs Additional contributors to switching speed With GPIB, LAN, or USB control Add 900 μs (nom) from receipt of SCPI command or trigger signal With Opt AT1 attenuators Add 20 ms (nom) for any change in the mechanical attenuator or bypass switch. These are controllable via GPIB, LAN, or USB. These are not controllable via list or fast control port (Option CC1 or CC2). Add 1 µs (nom) when switching to or from any frequency in region A0. RF phase settling criteria Final frequency 10 MHz to 8.6 GHz Measured to phase settled within 0.1 radians of final phase. > 8.6 GHz to 17.3 GHz Measured to phase settled within 0.2 radians of final phase. > 17.3 GHz Measured to phase settled within 0.3 radians of final phase. RF amplitude settling criteria Measured to amplitude settled within 1 dB of final amplitude. 1. For list mode, each point is controlled by dwell time, which will be limited based on the larger of the two frequencies (start and end frequencies). Switching Speed Definitions Triggered Pulse Non-Pulsed RF Pulse Sync Output Undefined Pulse Video TRIG Pulsed RF TwTd Switching Time Latency Output Undefined Switching Time Latency Switching Speed Definitions List Pulse Pulse Sync Dwell Pulse Video Pulsed RF Output Undefined Non-Pulsed RF TwTdTwTd Dwell Output Undefined Output Undefined

13 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Synchronization Multiple UXG units can be synchronized together to have phase coherent outputs. This is useful for simulating angle-of-arrival (AoA) and phased array antenna wavefronts. Synchronization input connections 10 MHz input Accepts a basic external reference at 10 MHz. Achieves lower residual phase noise than a 10 MHz input at the system sync input. See the Rear Panel Connectors Section for connection details. System sync input Recommended external reference input for use in system environments where trigger jitter and phase stability are important. Accepts a wide variety of input frequencies. See the Rear Panel Connectors Section for connection details. 6 GHz input Provides high stability synchronization between multiple signal generators. This is not a general 6 GHz connection. Only the 6 GHz synchronization output from another compatible signal generator should be connected. See the Rear Panel Connectors Section for connection details. Synchronization output connections 10/100 MHz output Provides a basic external reference at 10 MHz or 100 MHz. Achieves better spectral purity than the system sync output. See the Rear Panel Connectors Section for connection details. System sync output Recommended external reference output for use in system environments where trigger jitter and phase stability are important. Normally provides a 250 MHz output, but other frequencies are available. See the Rear Panel Connectors Section for connection details. 6 GHz output Provides high phase stability synchronization between multiple signal generators. See the Rear Panel Connectors Section for connection details. System sync input Frequency 1 to 250 MHz in 1 MHz steps. Default value is 250 MHz. Lock range ± 1.0 ppm (nom) Amplitude 6 dBm ± 6 dB (nom). To optimize phase noise use 6 dBm ± 2 dB (nom) Input impedance 50 Ω (nom) Usage The input frequency is not auto-detected. It must be entered manually and must be accurate to within the lock range above. System sync output Frequency 10 MHz, 100 MHz, or 250 MHz, selectable. Multi-box synchronization overrides this selection and may use other frequencies. Amplitude 12 dBm (nom) Output impedance 50 Ω (nom)

6 GHz input

Lock range ± 1.0 ppm (nom) Amplitude 11 dBm ± 6 dB (nom) Input impedance 50 Ω (nom) Usage This input must be connected to the 6 GHz output (described below) or a similar output from another compatible signal generator. The signal generator will not function without a 6 GHz signal at this input.

6 GHz output

Amplitude 17 dBm (nom) Output impedance 50 Ω (nom) Usage A rigid jumper cable is provided to connect the 6 GHz output to the 6 GHz input. The jumper can be removed to distribute this signal to other equipment. When distributing this signal to multiple UXG signal generators, approximately 12 dB of loss is permissible before distribution amplifiers are required. One of the distributed outputs from a master signal generator must be connected back into the 6 GHz input of the master signal generator. Reference bandwidth Standard 25 Hz

14 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet List mode List mode lets you play out a list of PDW ’s located in and read from the instrument ’s FPGA memory. The memory contains a series of list points where each list point contains multiple signal attributes. This mode supports dynamic sequencing using the external trigger ports. Operating modes List of frequency, phase, amplitude, pulse, chirp, and modulation parameters such as Barker codes. Timing Uniform timer Standard Advance every 100 μs to 34 s Option SS3 Advance every 48 ns to 34 s (for frequencies from 10 MHz to 6.89 GHz) Dwell timer Standard Advance every 100 μs to 17 s Option SS3 Advance every 48 ns to 17 s (for frequencies from 10 MHz to 6.89 GHz) Number of points Arbitrary list 1 to 500,000 per table assuming 50 sequences. Lists and sequences share the same memory. Triggering Point trigger Auto, external, single, SCPI, timer, or trigger key List trigger Auto, external, single, SCPI, timer, or trigger key Sequence trigger Auto, external, single, SCPI, timer, or trigger key Markers Marker types List, sequence, point Number of configurable markers Up to 12 Settable marker parameters Polarity, delay Normal mode Normal mode is optimized for maximum update rate (throughput). If the fast control port (FCP) Option CC1 is installed, it provides the capability to use pulse descriptor words (PDWs) to control frequency, amplitude, phase, pulse (include chirp or phase coding), and FM or ΦM. The PDW is streamed into the rear-panel FCP 100-pin connector using 48-bit wide control words. Fast CW mode Fast CW mode is optimized for minimum latency. The FCP control over signal attributes is limited to CW frequency switching and the addition of FM/ΦM provided this option was purchased. It is typically used with the FCP Option CC2 for compatibility with instruments used in legacy test systems. PDW streaming mode Streaming provides agile control of most of the instrument settings via a continuous stream of PDWs transferred from the internal SSD or an external source, such as a LAN or the Fast Control Port. The set of parameters controlled by Streaming include frequency, frequency band map, band adjust, relative power, phase, phase mode, pulse, pulse start time, FM (chirp) and PM (phase coding). Each PDW consists of seven 32-bit words. From file on solid state drive (SSD) PDW streaming rate 750 k pulses/s (nom) Over LAN port PDW streaming rate 750 k pulses/s (nom) Over fast control port (FCP) PDW streaming rate 6 M pulses/s (nom) Triggering PDW streaming trigger Auto, external, single, SCPI, timer, or trigger key PDW streaming trigger types Play, abort, or cancel

15 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Spectral purity Harmonics Measured at 10 dBm or maximum specified power, whichever is lower. Performance is unspecified for harmonics beyond the specified frequency range. Fundamental frequency Harmonic level 10 MHz to 2.61 GHz (Frequency Mode B) –25 dBc (typ)

10 MHz to 1 GHz (Frequency Mode A) –40 dBc

1 GHz to 2 GHz (Frequency Mode A) –50 dBc > 2 GHz –55 dBc Sub-harmonics Measured at +10 dBm or maximum specified power, whichever is lower. Sub-harmonics are defined as Carrier Freq *(x/N), where x is an integer, but ex - cluding harmonics. Does not apply to non-harmonic spurs which may overlap sub-harmonic spurs. Performance is unspecified for sub-harmonics beyond the specified frequency range. Fundamental frequency 1/2 and 3/2 sub-harmonics Other sub-harmonics N 0.01 to < 1.43 GHz None None 1 1.43 to < 2.85 GHz –75 dBc –80 dBc 2 2.85 to < 5.7 GHz –75 dBc –80 dBc 4 5.7 to < 11.4 GHz –75 dBc –80 dBc 8 11.4 to < 16 GHz –70 dBc –80 dBc 16 16 to 20 GHz –65 dBc (typ) –70 dBc (typ) 16 > 20 to < 22.8 GHz (Opt 54E) –70 dBc (typ) –70 dBc (typ) 16 22.8 to 40 GHz (Opt 54E) –70 dBc (typ) –70 dBc (typ) 32 Non-harmonics Measured in Frequency Mode A at +10 dBm or maximum specified power, whichever is lower. Performance is unspecified for non-harmonics beyond the specified frequency range. Fundamental frequency Offsets > 300 Hz excluding p ower-line related Power-line related 0.01 to < 1.43 GHz –70 dBc (typ) –60 dBc (typ) 1.43 to < 2.85 GHz –70 dBc (typ) –60 dBc (typ) 2.85 to < 5.7 GHz –70 dBc (typ) –50 dBc (typ) 5.7 to < 11.4 GHz –70 dBc (typ) –50 dBc (typ)

11.4 GHz to 20 GHz –70 dBc (typ) –50 dBc (typ)

20 GHz (Opt 54E) 1 –65 dBc (typ) –45 dBc (typ) Broadband noise In CW mode at +10 dBm or maximum specified output power, whichever is lower, for offsets > 10 MHz. Frequency Broadband noise

10 MHz to 20 GHz –131 dBc/Hz (typ)

20 GHz to 40 GHz (Opt 54E) –125 dBc/Hz (typ) 1. At precisely 22 GHz, several spurs coalesce and may add to -60 dBc. Moving 1 Hz away from 22 GHz avoids this issue.

16 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Phase noise Phase noise is measured using a CW signal at +10 dBm or maximum specified power, whichever is less, with spur optimizations off. Phase noise specifications exclude external mechanical vibration. Absolute SSB phase noise (dBc/Hz) Offset from carrier 20 kHz Frequency spec (typ) 0.01 to < 1.43 GHz –132 (–135) 1.43 to < 2.85 GHz –125 (–129) 2.85 to < 5.7 GHz –119 (–122) 5.7 to < 11.4 GHz –114 (–117) 11.4 to 20 GHz –109 (–112) > 20 GHz (Opt 54E) –103 (–106) Pulse modulation (Option PM2) For frequencies from 400 MHz to 1.43 GHz, pulse modulation specifications apply in Mode B only. For frequencies below 400 MHz, pulse modulation is not specified. Pulse types External input The RF pulse width is the same as the input pulse width at the pulse/trigger gate input connector. Triggered The internal pulse generator is triggered by a selectable trigger source. The pulse delay and width are settable. List mode The pulse parameters are defined in a list. Streaming mode The pulse parameters are defined in the streamed PDW data. Free run The internal pulse generator generates pulses with the specified parameters without waiting for a trigger. On/off ratio 0.4 to < 4.2 GHz 80 dB (90 dB typ)

4.2 GHz to 20 GHz 90 dB

20 GHz (Option 54E) 80 dB (90 dB typ) Rise/fall times 0.4 to < 1.43 GHz (6 ns typ) 1.43 to < 2.85 GHz 10 ns (6 ns typ) ≥ 2.85 GHz 10 ns (3 ns typ) Minimum pulse width ALC on 50 ns ALC off 10 ns (10 MHz to 31.6 GHz) 32 ns (> 31.6 GHz to 40 GHz) Minimum pulse repetition interval ALC on 60 ns (10 MHz to 31.6 GHz) 64 ns (> 31.6 GHz to 40 GHz) ALC off 20 ns (10 MHz to 31.6 GHz) 64 ns (> 31.6 GHz to 40 GHz) Level accuracy (relative to CW) For pulse width ≥ 100 ns with ALC on and for pulse width ≥ 10 ns with ALC off. 0.4 to < 1.43 GHz ± 1 dB (typ) ≥ 1.43 GHz ± 1 dB (typ)

17 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Width compression RF width relative to video out ± 5 ns (typ) Video feed-through For frequencies ≥ 400 MHz and output power of 10 dBm or less 10% (typ) Video delay External input to video output 60 ns (meas) RF delay (video to RF output) Frequency > 500 MHz 10 ns (meas) Pulse overshoot 10% (typ) Input level +1 V = RF on

0 V = RF off

50 Ω (nom) Sync Output Video Output RF Pulse Output 50% Td Tp Tw Tm 50% Vor Trf Vf 10% 90% Tr Tf Modified Figure for Thunderbird Datasheet

18 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Chirp and chirped-pulse modulation (Options UT1, WC2, and PM2)1 Option WC2 is required for chirp control through the Option CC1 I/O interface. Chirp type Options UNT or WC2 Linear frequency modulation (LFM) within pulse Option WC2 only CW chirp (available in list or streaming modes only) Pulse types Compatible without jitter Free-run, synchronously triggered With ± 8 ns jitter Asynchronously triggered 26.5 GHz to 31.6 GHz (Option 54E) Incompatible External pulse Pulse and chirp alignment Chirp start time is aligned to pulse start time within ± 50 ns (typ) Deviation (peak to peak) with Option UT1 Option 52E cannot chirp beyond 21.5 GHz. Option 54E cannot chirp beyond 40 GHz. Frequency Maximum peak to peak deviation

10 MHz to < 250 MHz 8 MHz

250 MHz to < 8 GHz 256 MHz

8 GHz to < 12 GHz 384 MHz

12 GHz to < 18 GHz 512 MHz

18 GHz to 20 GHz 768 MHz

20 GHz to < 26.5 GHz (Option 54E) 768 MHz ≥ 26.5 GHz to 31.6 GHz (Option 54E) 1024 MHz2 > 31.6 GHz to 40 GHz (Option 54E) 550 MHz Deviation (peak to peak) with Options UT1 and WC2 Option 52E cannot chirp beyond 21.5 GHz. Option 54E cannot chirp beyond 40 GHz. Frequency Maximum peak to peak deviation 50 MHz to 6.89 GHz 10% of center frequency > 6.89 GHz to 31.6 GHz (Option 54E) 2.2 GHz2 > 31.6 GHz to 40 GHz (Option 54E) 550 MHz Wider deviations are available up to 6.89 GHz when not near a band edge, for example, any chirp which lies within one band is obtainable. See the fre - quency band diagrams. Amplitude accuracy may degrade for wide chirps. Rate Range 10 kHz/μs to 1.3 GHz/ns Resolution 10 kHz/μs to 0.32768 kHz/ns depending on rate 1. If FCP (Fast Control Port) state is set to on and real-time streaming control is used, chirp and chirped-pulse modulation is only available for frequency range below 6.89 GHz. 2. Additionally, if chirp delta frequency is > 550 MHz or < -550 Hz, then the chirp start and stop frequency (stop frequency = start frequency + chirp delta) must both be ≤ 32.35 GHz. Measured pulse shape Frequency = 9 GHz, power = 10 dBm, amplitude = 10 dBm, ALC off, pulse width = 10 ns, pulse period = 100 ns. The oscilloscope is protected by a 10 dB pad and the timescale is set to 2 ns/div.

19 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Internal pulse generator (Option PM2) Internal pulse generator Modes Free-run, square, and triggered Square wave rate 0.1 Hz to 10 MHz with 0.1 Hz resolution (nom) Pulse period (PRI) (Tp) 30 ns to 42 s, corresponding to repetition frequencies of 0.024 Hz to 33.33 MHz. (10 MHz to 31.6 GHz) 32 ns to 42 s, corresponding to repetition frequencies of 0.024 Hz to 31.25 MHz. (> 31.6 GHz to 40 GHz) Minimum pulse width (Tw) 4 ns (nom) Delay resolution 10 ps PRI resolution 2 ns Width resolution 2 ns Frequency modulation (Option UT1) Maximum rate Internal or external 10 MHz Maximum peak deviation with Option UT1 Option 52E cannot deviate beyond 21.5 GHz. Option 54E cannot deviate beyond 40 GHz. Frequency Maximum peak deviation

10 MHz to < 250 MHz 4 MHz

250 MHz to < 8 GHz 128 MHz

8 GHz to < 12 GHz 192 MHz

12 GHz to < 18 GHz 256 MHz

18 GHz to 20 GHz 384 MHz

20 GHz to < 26.5 GHz (Option 54E) 384 MHz ≥ 26.5 GHz to 31.6 GHz (Option 54E) 512 MHz > 31.6 GHz to 40 GHz (Option 54E) 275 MHz Maximum peak deviation with Options UT1 and WC2 Option 52E cannot deviate beyond 21.5 GHz. Option 54E cannot deviate beyond 40 GHz. Frequency Maximum peak deviation 10 MHz to 6.89 GHz 5% of center frequency > 6.89 GHz to 20 GHz 1.1 GHz > 20 GHz to 31.25 GHz (Option 54E) 1.1 GHz > 31.25 GHz to 31.6 GHz (Option 54E) 750 MHz > 31.6 GHz to 40 GHz (Option 54E) 275 MHz Wider deviations are available up to 6.89 GHz when not near a band edge, for example, any FM deviation which lies within one band is obtainable. See the frequency band diagrams. Amplitude accuracy may degrade for wide FM. Resolution 0.1% of deviation or 1 Hz, whichever is greater Deviation accuracy Measured at a 1 kHz rate with 100 kHz deviation. Internal ± 1% of FM deviation (± 0.2% typ) External In ± 3.5% of FM deviation + 20 Hz Modulation frequency response (3 dB bandwidth) Measured at 100 kHz deviation. DC coupling AC coupling DC to 10 MHz (nom)

5 Hz to 10 MHz (nom)

External DC FM carrier offset At the calibrated deviation and carrier frequency, within 5 °C of ambient temperature at time of user calibration. ± 0.1% of set deviation (meas) Distortion Measured at a 1 kHz rate with 100 kHz deviation. 0.4% Sensitivity ± 1 Vpeak for indicated deviation Frequency Coding (FSK) Number of levels Minimum bin width Maximum pattern length 16 levels, at least 32 maps 4 ns 65,536 bits/pattern

20 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Phase modulation (Option UT1) Maximum rate Internal or external 10 MHz Maximum peak deviation in radians 5% of carrier frequency 600 MHz or or 12 whichever is lessmodulation frequency modulation frequency π Resolution 0.1% of set deviation Deviation accuracy Measured at a 1 kHz rate with 3π rad deviation. Internal ± 1 % of M deviation (± 0.2% typ) External In ± 3.5% of M deviation Modulation frequency response (3 dB bandwidth) Measured at 3π rad deviation. DC coupling DC to 10 MHz (nom) AC coupling 5 Hz to 10 MHz (nom) Distortion Measured at a 1 kHz rate with 3π rad deviation. Total harmonic distortion 0.5% (0.1% typ) Sensitivity ± 1 Vpeak for indicated deviation Phase Modulation Types Triggered BPSK Phase can be changed 180˚ on a bin-by-bin basis every 8 ns via an external trigger Barker Coding Supported Codes 2, 3, 4, 5, 7, 11, 13 Phase Coding (PSK) Number of levels Minimum bin width Maximum pattern length 16 levels, at least 32 maps 4 ns 65,536 bits/pattern Amplitude modulation (Option UT1) AM performance is typical up to 20 GHz with ALC on when AM peaks do not exceed maximum specified power. AM performance is not specified with ALC off or above 20 GHz or when AM peaks exceed maximum specified power. Maximum depth 80% (14 dB) Depth accuracy ALC on, 1 kHz rate and depth ≤ 80% ± (6% of setting + 1%) External input (selectable polarity) Sensitivity for indicated depth 1 Vpeak Maximum voltage ± 1 V Modulation frequency response (3 dB bandwidth) Measured at 30% depth. DC coupling DC to 10 MHz (nom) AC coupling 5 Hz to 10 MHz (nom) Distortion 30% AM, 1 kHz rate 1.5% total harmonic distortion 60% AM, 1 kHz rate 2% total harmonic distortion External modulation inputs (Option UT1) Connections Ext1 and Ext2 Modulation types AM, FM, and M Input impedance 50 Ω, 600 Ω, or 1 MΩ (nom) switched

21 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Internal modulation source (Option UT1) Dual function generators Provide two independent signals (internal1 and internal2) for use with AM, FM, M, or LF output. Waveforms Sine, square, positive ramp, negative ramp, triangle, pulse, uniform noise, Gaussian noise. Rate range Sine 0.1 Hz to 10 MHz Square, ramp, triangle 0.1 Hz to 1 MHz Resolution 0.1 Hz Accuracy Same as timebase LF output Output Internal 1, internal 2, noise generator 1, noise generator 2. Also provides monitoring of function generators when used for AM, FM, or M. Amplitude 0 to 5 Vpeak (nom) into 50 Ω or 10 V (nom) into 1 MΩ Output impedance 50 Ω (nom) Remote programming Interfaces GPIB (IEEE-488.2,1987) with listen and talk, USB 2.0, and 1000BaseT LAN interface. Control languages SCPI version 1997.0. Code compatibility modes for Aeroflex 2500, 2200, FS2000 or FS5000. IEEE-488 functions SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP0, DC1, DT0, C0, E2 Keysight IO libraries Keysight’s IO Library Suite helps you quickly establish an error-free connection between your PC and instruments, regardless of the vendor. It provides robust instrument control and works with the software development environment you choose. Simultaneous modulation Simultaneous modulation All modulation types (FM, AM, M, chirp, and pulse modulation) may be simultaneously enabled except FM with M . AM, FM, and M can sum simultaneous inputs from any two sources (Ext1, Ext2, internal1, or internal2). Any given source (Ext1, Ext2, internal1, or internal2) may be routed to only one activated modulation type. General specifications Power requirements 100/120 VAC 50/60/400 Hz or 220/240 VAC 50/60 Hz (automatically selected) < 350 W typical, 400 W maximum Operating temperature range 0 to 55 °C Storage temperature range –40 to 70 °C; during storage below –20 °C, instrument states may be lost. Altitude 0 to 4600 m (15,000 ft) Humidity Relative humidity - type tested at 95%, +40 °C (non-condensing). Environmental testing Samples of this product have been tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environmental stresses of storage, transportation, and end-use. Those stresses include but are not limited to temperature, humidity, shock, vibration, altitude, and power line conditions. Test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF- 28800F Class 3. Phase noise specifications are not warranted in a vibrating environment. ISO compliant This family of signal generators is manufactured in an ISO-9001 registered facility in concurrence with Keysight’s commitment to quality. EMC Conforms to the immunity and emission requirements of IEC/EN 61326-1 including the conducted and radiated emission requirements of CISPR Pub 11/2009 Group 1, Class A. Acoustic noise Normal: 48 dBA (nom) Worst case: 68 dBA (nom) Storage Memory is shared by instrument states and sweep list files. The solid-state drive initially has at least 480 GB of free space.

22 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Input/Output Descriptions Front panel connectors Unless otherwise noted, all connectors are BNC female, digital inputs and outputs are 3.3 V CMOS, and digital inputs will accept 5 V CMOS, 3 V CMOS, or TTL voltage levels. Option 1EM moves all connectors to the rear panel except the USB connectors. RF output Output impedance 50 Ω (nom). Option 52E Standard: Precision APC-3.5 male; plus 3.5 - 3.5 mm female adapter Option 1ED: Type-N female; plus Type-N male - 3.5mm female adapter LF output Outputs the internally generated LF source. Nominal output impedance 50 Ω. External input 1 Drives either AM, FM, or M . Nominal input impedance is 50 Ω, 600 Ω, or 1 MΩ, selectable. Damage levels are 5 V rms and 10 Vpeak . External input 2 Drives either AM, FM, or M . Nominal input impedance is 50 Ω, 600 Ω, or 1 MΩ, selectable. Damage levels are 5 Vrms and 10 Vpeak . Pulse/trigger gate input Accepts input signal for external pulse modulation. Also accepts external trigger pulse input for internal pulse modulation. Nominal impedance 50 Ω. Damage levels are 5 V rms and 10 Vpeak . Pulse video out Outputs a signal that follows the RF output for internal pulse modes. TTL-level compatible. Nominal source impedance 50 Ω. Pulse sync out Outputs a synchronizing pulse, nominally 50 ns width, for internal pulse modes. TTL-level compatible, nominal source impedance 50 Ω. Rear panel connectors Unless otherwise noted, all connectors are BNC female, digital inputs and outputs are 3.3 V CMOS, and digital inputs will accept 5 V CMOS, 3 V CMOS, or TTL voltage levels. Option 1EM moves the front panel connectors to the rear panel except the USB connectors. GPIB Operates as a GPIB controller or device. IEEE-488 bus connector. LAN (1000 BaseT) Allows LAN TCP/IP communication. RJ45 Ethertwist connector. The LAN connector provides the same SCPI remote programming functionality as the GPIB connector. The LAN connector is a used to access the internal web server and FTP server. The LAN supports DHCP, HiSLIP, sockets SCPI, VXI-11 SCPI, connection monitoring, dynamic hostname services, and TCP keep alive. This interface is LXI class C compliant. PCIe x8 Provides 8 lanes of PCIe I/O. Reserved for future use. 10 MHz input Accepts a 10 MHz external reference (timebase) input. Nominal input impedance 50 Ω. Nominal input range 0 to 12 dBm. 10/100 MHz output Provides a reference signal of 10 MHz or 100 MHz, selectable. Nominal output impedance 50 Ω. Nominal output power 7 dBm. Suitable for use with the 10 MHz input or System Sync input of another compatible signal generator. 10 MHz EFC Accepts an external DC voltage, ranging from -10 V to +10 V, for electronic frequency control (EFC) of the internal 10 MHz reference oscillator. This voltage inversely tunes the oscillator about its center frequency. See the EFC sensitivity in the frequency section. The nominal input impedance is greater than 1 MΩ. Security Display blanking Memory clearing functions (See Application Note, “Security Features of Keysight Technologies Signal Generators,” Part Number E4400-90621). Removable Solid State Drive (SSD) with all user data. Self-test Internal diagnostic routine tests most modules in a preset condition. If node voltages are within acceptable limits, then the module passes the test. Weight < 25 kg (54 lb.) net < 34 kg (73 lb.) shipping Dimensions 134 mm H x 426 mm W x 559 mm D (5.25” H x 16.8” W x 22.0” D) Recommended calibration cycle 12 months

23 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet Fast Control Port (FCP) interface modules Option CC1 I/O interface Data port 100 pin LVDS Triggers and markers 2 SMA and 12 SMB Data format Binary Controllable parameters Frequency, amplitude, phase, phase coding, band, pulse, chirp, FM deviation, M deviation, depending on installed options. Option CC2 I/O interface Data connector 50 pin Triggers and markers 2 SMA Data format Binary coded decimal (BCD) Controllable parameters Frequency, FM deviation System sync input Accepts an external reference input. The acceptable frequencies are listed in the synchronization section. Nominal input impedance 50 Ω. Nominal input range 0 to 12 dBm. System sync output Provides an external reference output of 10, 100, or 250 MHz, selectable. Nominal output impedance 50 Ω. Nominal output power 12 dBm. Suitable for use with the System sync input. 6 GHz input SMA female connector. Accepts a synchronization input of 6 GHz. Nominal input impedance 50 Ω. Nominal input range 5 to 17 dBm. Damage levels are above +23 dBm. 6 GHz output SMA female connector. Provides a synchronization output of 6 GHz. Nominal output impedance 50 Ω. Nominal output power 17 dBm. Suitable for use with the 6 GHz input. Related Literature N5191A UXG Brochure, 5992-1096EN N5191A UXG Configuration Guide, 5992-1116EN

24 | Keysight | N5191A UXG X-Series Agile Signal Generator, Modified Version - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Keysight Infoline www.keysight.com/find/Infoline Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. KEYSIGHT SERVICES Keysight Services www.keysight.com/find/services Our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. The result? We help you implement new technologies and engineer improved processes that lower costs. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/n5191a For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-06-08-16) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2015 - 2016 Published in USA, July 14, 2016 5992-1095EN www.keysight.com Evolving Our unique combination of hardware, software, support, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight