Export department: +48 68 45 75 139/276/386 Fax: +48 68 32 54 091 e-mail: export@lumel.com.pl lUmel S.a. ul. Sulechowska 1 65-022 Zielona góra pOland WWW.LUMEL.COM.PL N20 digital panel meter GALVANIC ISOLATION: INPUTS: OUTPUTS: FEATURES: Outputs Kind of inputs Features Alarm outputs • 2 alarm outputs of OC type Outputs for external supply of transducers • 24 V ± 5%, 30 mA Eample of application
- Measurement of voltage or d.c. current and temperature (Pt100, J, K):
- Three-colour LED display (5 digits, 14 mm high).
- 2 alarm outputs of OC type.
- Galvanic separati on between the supply, measuring inputs and the programmer input.
- Programmable parameters through the PD14 programmer: – recounti ng of indicati ons (individual characteristi c), – two alarms of OC type operati ng in 6 working modes, – display colour programmable in three intervals, – thresholds of displayed overfl ows, – highlight of the unit, – automati c or manual compensati on: temperature of cold ends (for J, K) or wire resistance (for Pt100), – measurement averaging ti me.
- Supply of object transducers. Inputs Kind of inputs Measuring range Parameters Basic error Voltage input Input resistance: >1 MΩ ± (0.2% of range + 1 digit) Current input Input resistance: 10 Ω ± 1% Input resistance: 10 Ω ± 1% Input resistance: 5 Ω ± 1% Temperature measurement Pt100 - 50...400°C Temperature measurement through J thermocouple - 50...1200°C Temperature measurement through K thermocouple - 50...1370°C Measurement and signalling of temperature overflows or d.c. current Alarms PD14 programmer Pt100 temperature sensor N20 digital meter configuration through eCon program Supply output 24 V d.c. Eternal features Readout fi eld 5 digital LED displays. Indicati on range -19999...99999 Digit height: 14 mm Three-colour display (changes of colour depend on the displayed value): red, green, orange. Weight < 0.25 kg Overall dimensions 96 48 64 mm Panel cut-out: 92 +0,6 45+0,6 mm Protecti on grade (acc. to EN 60529)From frontal side: IP65 From terminal side: IP10 2 x Shunt Current
and measuring input 3.2 kV d.c. Fig. 2 Connections of measuring inputs. Table 2. Codes of highlighted unit:
01 V 18 mm 35 rad
02 A 19 cm 36 Ω
05 MV 22 l 39 °
08 MA 25 ms 42 rpm
11 K 28 N 45 km/h
12 Hz 29 kN 46 imp
14 Ah 31 hPa
Fig. 1 Electrical connections of N20 meter. Table 1. Ordering codes: standard, one must give values of ALL parameters.