DA6011.000

15 September 2008

1 (8) MAS6011 Solar Cell System Manager

  • Power Down Indicator
  • Low Battery Indicator
  • Battery Overcharging Protection

DESCRIPTION

MAS6011 solar cell system manager monitors the supply voltage of a battery-powered system containing solar cells. Current consumption of this IC is extremely low. The solar manager uses three output signals to indicate the state of the system. Power Down (XPD) indicates whether the supply voltage is high enough to run the system. Low Battery (LB) is used to signal the situation where the battery is low. The third signal, SOL, is used for battery charging control. When the battery is full it bypasses the charging current by an internal switch to avoid overcharging of the battery. FEATURES APPLICATIONS

  • Power Down Indicator
  • Low Battery Indicator
  • Battery Overcharging Protection
  • Suitable for VL-type Rechargeable Lithium Batteries
  • Solar Powered Watch
  • Solar Powered Equipment BLOCK DIAGRAM LB XPD VDD SOL GND MAS6011 This is advance information on a new product under development. Micro Analog Systems Oy reserves the right to make any changes without notice.

DA6011.000 2 (8) PAD LAYOUT: MAS6011AA3 1040 µµ µµ m 1540 µµµµ m SOL VDD GND LB XPD MAS6011 DIE size = 1040 mm x 1540 mm PAD size = 80 x 80 µ m Note: This is a CMOS device and therefore it should be handled carefully to avoid any damage by static voltages (ESD). Make sure that GND is the first pad to be bo nded. Pick-and-place and all component assembly are recommended to be performed in ESD protected area. Note: If the die is to be placed on metal plane, the met al plane should be connected to GND or left floatin g because the substrate of the die is internally connected to GND. Note: Coordinates are pad center points where origin has been located in the center of the silicon die. Pad Identification Name X-coordinate Y-coordinate Power Supply Ground GND -129 µ m 563 µ m Power Down Output XPD 253 µ m 563 µ m Solar Charging Output SOL -167 µ m -563 µ m Power Supply Voltage VDD 102 µ m -563 µ m Low Battery Output LB 253 µ m -563 µ m

internal diode-connected PNP transistor. rechargeable lithium batteries. Figure 1. MAS6011 functions

DA6011.000 4 (8) ABSOLUTE MAXIMUM RATINGS All voltages with respect to ground. Parameter Symbol Conditions Min Max Unit Supply Voltage VDD -0.3 6.0 V Voltage range for all pins -0.3 VDD+0.3 V Operating temperature T A -20 +60 oC Storage Temperature T S -50 +125 oC Stresses beyond those listed may cause permanent damage to the device. The device may not operate under these conditions, but it will not be destroyed. This is a CMOS device and therefore it should be handled carefully to avoid any damage by static voltages (ESD). ELECTRICAL CHARACTERISTICS: MAS6011AA3 (3V BATTERY, MCU VDD min ≤≤ ≤≤ 2.1V) TA = -20° C to +60° C, typical values at T A = +27° C, unless otherwise specified. Parameter Symbol Conditions Min Typ Max Unit Supply voltage VDD 2.0 3.0 3.6 V Current consumption I Q 130 nA XPD switching level XPD_OFF XPD_ON Power Down Off (XPD high) Power Down On (XPD low) 2.50 2.10 2.70 2.30 2.90 2.50 V XPD hysteresis V XPD(H) 200 400 mV XPD output voltage V XPD(OUT) VDD = 2.1 V, IXPD = -150 µ A 2.0 V LB switching level LB_OFF LB_ON Low Battery Off (LB low) Low Battery On (LB high) 2.60 2.35 2.75 2.50 2.90 2.65 V LB hysteresis V LB(H) 100 250 mV LB output voltage V LB(OUT) VDD = 2.1 V, I LB = -50 µA VDD = 3.0 V, I LB = +50 µA 2.05 0.05 V SOL switching level SOL_OFF SOL_ON Solar Charging Off Solar Charging On 3.05 2.85 3.25 3.15 3.55 3.45 V SOL hysteresis V SOL(H) 50 100 mV SOL sink current I SOL VDD = 3.2 V, SOL = 0 V, SOL switch On 22 mA SOL leakage current VDD = 2.9 V -50 50 nA LB_OFF – XPD_OFF V LB_XPD_OFF 50 mV LB_ON – XPD_ON V LB_XPD ON 100 200 300 mV SOL_OFF – LB_OFF V SOL_LB_OFF 500 mV SOL_ON – LB_ON V SOL_LB ON 350 650 mV TBD = To be defined

Figure 2. Typical application circuit of MAS6011AA3 – XPD as power on control signal for a Figure 3. Typical application circuit of MAS6011AA3 – XPD as supply voltage for a low power

DA6011.000 6 (8) MAS6011AA3 SAMPLES IN SBDIL 20 PACKAGE VDD 1 GND 2 NC 3 NC 4 NC 5 NC 6 NC 7 NC 8 NC 9 NC 10

20 SOL

11 XPD

XXXXX.X Top Marking Definitions: YYWW = Year Week XXXXX.X = Lot Number x = Sample Version Number SBDIL 20 PIN DESCRIPTION Pin Name Pin Type Function VDD 1 P Positive Power Supply GND 2 G Power Supply Ground XPD 11 DO Power Down Output LB 12 DO Low Battery Output NC 13, 14, 15, 16, 17, 18, 19 SOL 20 AO Solar Charging Output NC = Not Connected, P = Power, G = Ground, DO = Digital Output, AO = Analog Output MAS6011AA3 IN QFN 3x3 PACKAGE Top Marking Information: 1234 = Product Number, AA3 = Version Number G = Lead Free, RoHS Compliant Package, YWW = Year Week QFN 3x3 PIN DESCRIPTION Pin Name Pin Type Function SOL 1 AO Solar Charging Output VDD 2 P Positive Power Supply LB 3 DO Low Battery Output XPD 4 DO Power Down Output 5 NC GND 6 G Power Supply Ground NC = Not Connected, P = Power, G = Ground, DO = Digital Output, AO = Analog Output QFN 3x3 6ld SOL GND LB VDD XPD 1234 GAA3 YWW 2 3

DA6011.000 7 (8) D/2 E/2 SEATING PLANE SIDE VIEW TOP VIEW D2/2 E2/2 L b BOTTOM VIEW D e PIN 1 MARK AREA A EXPOSED PAD SHAPE OF PIN #1 IDENTIFICATION IS OPTIONAL PACKAGE (QFN 3X3x0.75 6ld) OUTLINE Symbol Min Nom Max Unit PACKAGE DIMENSIONS A 0.70 0.75 0.80 mm A1 0.0 0.02 0.05 mm A3 0.178 0.203 0.228 mm b 0.350 0.400 0.450 mm D 3.00 BSC mm D2 (Exposed pad) 2.25 2.3 2.35 mm E 3.00 BSC mm E2 (Exposed pad) 1.45 1.5 1.55 mm e 0.95 BSC mm L 0.425 0.475 0.525 mm Dimensions do not include mold or interlead flash, protrusions or gate burrs.

DA6011.000 8 (8)

ORDERING INFORMATION

Product Code Product Package Comments MAS6011AA3WA300 Solar Cell System Manager (for 3 V rechargeable battery) Tested wafer, thickness 400 µ m MAS6011AA3Q1306 Solar Cell System Manager (for 3 V rechargeable battery) QFN 3x3x0.75mm Pb-free RoHS compliant Tape and Reel Please contact Micro Analog Systems Oy for 1.5 V rechargeable battery voltage version. LOCAL DISTRIBUTOR MICRO ANALOG SYSTEMS OY CONTACTS Micro Analog Systems Oy Kamreerintie 2, P.O.Box 51 FIN-02771 Espoo, FINLAND http://www.mas-oy.com Tel. (09) 80 521 Tel. Int. +358 9 80 521 Telefax +358 9 805 3213 E-mail: info@mas-oy.com