MA12 SYSTEMSENSOR | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

System Sensor's Multi-Alert sounder and sounder/strobes are suited to pr ovide primary or secondary signaling for fire and security applications. The MA and MASS models provide eight field-selectable warning tones. The Multi-Alert models mount directly to 4 ″ square back boxes. Optional mounting plates are available for either flush or semi-flush installations. Model MA12/24D is suitable for outdoor applications when installed with the WBB weather-proof back box. Multi-Alert Strobes. System Sensor’s Multi-Alert strobes are UL1638 compliant electronic visible warning signals that flash approximately every 1.5 seconds. All circuits are polarized to be compatible with DC alarm supervision. Mini-Alert Sounders. System Sensor’s PA400 series Mini-Alert sounders operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The PA400 sounders are available with or without FIRE identification, and are offered in red, beige, and white. Multi-Alert Models Sounder MA12/24D Strobes Sounder/Strobes SS24LO MASS24LO SS24M MASS24M SS24LOLA MASSLOLA Mini-Alert Sounders Red Beige White PA400 PA400 PA400W PA400R-F PA400B-F PA400W-F Add-on Strobes Red White PS24LO PS24LOW Product Overview MA12/24D Multi-Alert ™ & Mini-Alert ™ Sounders and Strobes Multi-Alert Sounder: 12 and 24V operation 8 field-selectable tones Multi-Alert Strobes and Sounder/Strobes: 24V operation 1.5 or 15 candela UL1638 listed Mini-Alert Sounders: 12 and 24V operation 1.5 cd add-on strobe available Multi-Alert Sounders shall be a System Sensor Model MA 12/24D capable of operating at 12 and 24VDC. Sounder shall be listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Sounder shall have an operating temperature between –31°F and 151°F. Sounder shall have eight tone options, selected by means of clips. Mini-Alert Sounders shall be a System Sensor Model ——— capable of operating at 12 and 24VDC. Sounder shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems. Sounder shall have an operating tem- perature between 14°F and 140°F. Multi-Alert and Mini-Alert Sounder/Strobes shall be a System Model ——— capable of operating at 24VDC. Sounder/strobe shall be listed to Underwriter’s Laboratories Standards UL464 and UL1638 for fire protective signaling systems. Sounder/strobe shall have an operating temperature between 32°F and 120°F. Strobe shall be powered independently of the sounder and shall operate at 24VDC, with a UL range rating of 22.5 to 30VDC. Actual operating voltage must be between 18 and 33VDC. Strobe shall have a minimum light output of 1.5 or 15 candela and shall be UL1638 listed for private mode applications. PA400W Engineering Specifications PA400R-F

System Sensor Headquarters

3825 Ohio Avenue

St. Charles, IL 60174 Ph: 800-SENSOR2 Fx: 630/377-6495 Documents on Demand 1-800-736-7672 x3 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 011.44.1403.276500 Fx: 011.44.1403.276501 System Sensor in China Ph: 011.86.29.524.6253 Fx: 011.86.29.524.6259 System Sensor in Singapore Ph: 011.65.273.2230 Fx: 011.65.273.2610 System Sensor– Far East Ph: 011.85.22.191.9003 Fx: 011.85.22.736.6580 System Sensor– Australia Ph: 011.613.54.281.142 Fx: 011.613.54.281.172 System Sensor Sales and Service © 1999 System Sensor. The company reserves the right to change product specifications without notice. A05-207-07•11/99(10K)•#571 Multi-Alert Sounder Specifications Dimensions 4″ x 4″ x 2 1/4″ Weight 5.7 oz. (162 g) Operating Voltage 12VDC to 24VDC FWR unfiltered* Mounting Surface 4 ″ x 4″ back box (1 1/2″ to 2 1/8″ deep) Flush 4 ″ x 4″ BBD deep back box (2 3/4″ deep) Semi-flush 4 ″ x 4″ back box (1 1/2″ to 2 1/8″ deep) with MP-SF mounting plate Input Terminals 12 to 18 AWG Operating Temperature Range *Actual 12 V operating voltage cannot be less than 9.6VDC or greater than 18.7VDC. Actual 24 V operating voltage cannot be less than 18VDC or greater than 33VDC. Multi-Alert Strobe Specifications Dimensions 4″ x 4″ x 2 15/16″ Weight 8.2 oz. (232 g) Operating Voltage 24VDC and FWR unfiltered* Mounting Surface 4 ″ x 4″ back box (1 1/2″ to 21/8″ deep) Semi-flush 4 ″ x 4″ back box (1 1/2″ to 21/8″ deep) with MP-SF mounting plate Input Terminals 12 to 18 AWG Operating Temperature Range *Actual 24V operating voltage cannot be less than 18VDC or greater than 33VDC. Mini-Alert Specifications Dimensions Weight 2.4 oz. (159 g) Operating Voltage 12VDC to 24VDC FWR unfiltered* Mounting Surface Single gang back box Flush 4 ″ x 4″ BBD deep back box (2 3/4″deep) Input Terminals 12 to 18 AWG Operating Temperature Range *Actual 12V operating voltage cannot be less than 9.6VDC or greater than 18.7VDC. Actual 24V operating voltage cannot be less than 18VDC or greater than 33VDC. Ordering Information/Current Draw Average dB Output Red Beige White Description Voltage Current Candela (UL)*** MA12/24D Multi-Alert sounder 12/24VDC * — 75–85 SS24LO Multi-Alert strobe 24VDC 25 mA 1.5 — SS24M Multi-Alert strobe 24VDC 75 mA 15.0 — SS24LOLA Multi-Alert strobe (“FUEGO” lens) 24VDC 25 mA 1.5 — MASS24LO Multi-Alert sounder /strobe 24VDC 1.5 75–85 MASS24M Multi-Alert sounder /strobe 24VDC 15.0 75–85 MASS24LOLA Multi-Alert sounder/strobe (“F UEGO” lens) 24VDC ** 1.5 75–85 PA400R PA400B PA400W Mini-Alert sounder 12/24VDC 12/15 mA — 82 PA400R-F P A400B-F PA400W-F Mini-Alert sounder (“Fire” identification) 12/24VDC 12/15 mA — 82 PS24LO PS24LOW Add-on strobe 12/24VDC 5 mA 1.5 82 Multi-Alert/Mini-Alert Model Numbers Accessory Model Numbers

Description

MP-F/MP-FB Flush mounting plate (red/beige) MP-SF/MP-SFB Semi-flush mounting plate (red/beige) BB-D Flush mounting deep back box, 2 3/4″ deep WBB Weatherproof back box for MA 12/24D * Current ranges from 10mA to 55mA depending upon voltage and sound selected Current ranges from 35mA to 80mA depending upon voltage and sound selected * Sound output varies depending upon voltage and sound selected. Note: LO and M style strobe and sounder/strobe models are not MEA approved.