MA16L LUMEL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 6

Technical content

www.lumel.com.pl APPLICATION The panel meters type MA12L, MA16L, MA17L, MA19L are designed to measure current or DC voltage. Magnetoelectric meters with built-in rectifier type MA12L(P), MA17L(P), MA19L(P). are intended for me- asuring the effective currents and alternating current with sinusoidal waveform. Measurement of the current and voltage of the non-sinu - soidal waveform is subject to a large error proportional to the degree of deformation of the waveform. what follows from the principle of measuring the rectifier device. which reacts to the average value of the straight-run. but it is calibrated like this. to indicate the effective value of the sinusoidal waveform. Where the noninusoidal course is appropriately characterized. this measurement error is calculated. Therefore, the requirements for the influence of the shape of the curve for the medium-responsive instrument (straightened) are not specified in the standard EN 60051-2. MA12L, MA16L, MA17L, MA19L meters are suitable for mounting in a panel of thickness not exceeding 25 mm in the holes according to Figures 2 and 4. TeChNICAL dATA Accuracy class 1 Type of scale 0...240° Measurement ranges for DC and AC voltage and current meters and electrical data acc. table 1. 2. 3 Rated operating conditions: - relative humidity 25...75% Notice: mV can be made with interchangeable indicatin dial (scale) with any measuring range of the shunt. Other ranges can also be made with an interchangeable scale provided, that the measuring range of the meter will be the equivalent of the measuring range of the measuring transducer. The interchangeable scale The interchangeable scale is inserted and removed by the sliding gap in the top or side of the housing. CATEGORIES OF METER CLIMATIC VERSIONS Meters in the basic versions are designed for use in moderate climatic conditions. indoor. non-air conditioned rooms. On customers’ request. meters can be adapted to use in conditions of a dry or wet tropical climat in non-air conditioned rooms. Then. they are marked with the TIII symbol. Requirements concerning safety acc. EN 61010-1 standard: - installation category: III - pollution level: 2 - maximal phase-earth working voltage: 660 V (for MA16L)

1000 V (for MA12L, MA17L, MA19L)

  • voltage test: 2kV Electromagnetic compatibility: - meters meet CE requirements - noise immunity acc. to EN 61000-6-2 - noise emissions acc. to EN 61000-6-4 Electrical overload: - long-term: 120% In, 120% Un - short-time current measurement: 10 times for 5s: 1 overload 10 times for 0.5s: 9 overloads - short-term voltage measurement: 2 times for 5s: 1 overload 2 times for 0.5s: 9 overloads Impact resistance - peak acceleration 15 g - duration of impact 11 ms Shock resistance - range of vibration frequency 10-55-10Hz - vibration amplitude 0.15mm (corresponds to 1.5g at 50 Hz) Protection Grade acc. to EN 60529 ensured by: - housing: standard IP 52 on request IP 65 - MA19L, MA17L, MA16L - terminals IP 20 Housing material thermoplastic, self-extinguishing plastic (UL 94V-O) Glass material glass (in standard) anti-reflective glass on request ACCESSORIES screw holders - 2 pcs (for MA16L, MA17L, MA19L) or 4 pcs (for MA12L). MA16L, MA17L, MA19L, MA12L MOVING-COIL METERS AMMETERS and VOLTMETERS (with scale 240o) MA12LMA19LMA17LMA16L

www.lumel.com.pl RANGE OF CURRENT AND CONTINUOUS VOLTAGE. INTERNAL RESISTANCE OR VOLTAGE DROP Table 1 Frontal fame dimensions [mm] 48 x 48 72 x 72 96 x 96 144 x 144 Scale lenght [mm] 70 106 142 230 Weight [kg] 0.13 0.25 0.30 0.43 Type MA16L MA17L MA19L MA12L Internal resistance or voltage drop Measuring range zero on the side of the scale zero in the middle of the scale zero on the side of the scale zero in the middle of the scale zero on the side of the scale zero in the middle of the scale zero on the side of the scale zero in the middle of the scale 100 mA 970 mV 600 mV 600 mV 600 mV 150 mA 970 mV 400 mV 400 mV 400 mV 250 mA 810 mV 140 mV 140 mV 140 mV 400 mA 900 mV 540 mV 540 mV 540 mV 600 mA 900 mV 540 mV 540 mV 540 mV 1 mA 500 mV 37 mV 37 mV 37 mV 1.5 mA 500 mV 196 mV 196 mV 196 mV 2.5 mA 500 mV 196 mV 196 mV 196 mV 4 mA 500 mV 196 mV 196 mV 196 mV 5 mA 40 mV 196 mV 196 mV 196 mV 6 mA 40 mV 196 mV 196 mV 196 mV 10 mA 75 mV 196 mV 196 mV 196 mV 15 mA 60 mV 11 mV 11 mV 11 mV 20 mA 60 mV 60 mV 60 mV 60 mV 25 mA 60 mV 11 mV 11 mV 11 mV 40 mA 60 mV 60 mV 60 mV 60 mV 60 mA 60 mV 60 mV 60 mV 60 mV 100 mA 60 mV 60 mV 60 mV 60 mV 150 mA 60 mV 60 mV 60 mV 60 mV 250 mA 60 mV 60 mV 60 mV 60 mV 400 mA 60 mV 60 mV 60 mV 60 mV 600 mA 60 mV 60 mV 60 mV 60 mV

1 A 60 mV 60 mV 60 mV 60 mV

1.5 A 60 mV 60 mV 60 mV 60 mV

2.5 A 60 mV 60 mV 60 mV 60 mV

4 A 60 mV 60 mV 60 mV 60 mV

6 A 60 mV 60 mV 60 mV 60 mV

10 A 60 mV 60 mV 60 mV 60 mV

15 A 60 mV 60 mV 60 mV 60 mV

20 A 60 mV 60 mV 60 mV 60 mV

25 A 60 mV 60 mV 60 mV 60 mV

4...20 mA 60 mV 60 mV 60 mV 60 mV For the connection of the shunt ... A/60 mV 200 W/ V 200 W/ V 200 W/ V 200 W/ V ...A/150 mV 200 W/ V 200 W/ V 200 W/ V 200 W/ V 60 mV 200 W/ V 200 W/ V 200 W/ V 200 W/ V 100 mV 200 W/ V 200 W/ V 200 W/ V 200 W/ V 150 mV 200 W/ V 200 W/ V 200 W/ V 200 W/ V 250 mV 200 W/ V 200 W/ V 200 W/ V 200 W/ V 400 mV 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V 600 mV 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/V 1000 W/V 1000 W/ V 1000 W/ V

www.lumel.com.pl Table 1 1 A 1.5 A 2.5 A 4 A 6 A 10 A 15 A 25 A 40 A 60 A 100 A 150 A 250 A 400 A 600 A 1 kA 1.5 kA 2.5 kA 4 kA 6 kA 10 kA 15 kA 1. Measuring movement current considerated when calibrating shunts: B2 - 60 mV – 10 mA B3 - 150 mV – 5 mA 2. Resistance of conductors linking the meter with the shunt: 0.035 W 3. After agreeing with the producer it is possible to offer shunts with following standarized voltage drops: 50 mV. 75 mV. 100 mV 4. Further particulars on shunts are contained in heit data sheet avaiable on the website www.lumel.com.pl Table 2 DC mEASURING RANGES wITh ExTERNAL ShUNTS Typ MA16L MA17L MA19L MA12L Internal resistance or voltage drop Measuring range zero on the side of the scale zero in the middle of the scale zero on the side of the scale zero in the middle of the scale zero on the side of the scale zero in the middle of the scale zero on the side of the scale zero in the middle of the scale

1 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

1.5 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

2.5 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

4 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

6 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

10 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

15 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

25 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

40 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

60 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

100 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

150 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

250 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

300 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

400 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

500 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

600 V 1000 W/ V 1000 W/ V 1000 W/ V 1000 W/ V

www.lumel.com.pl exTerNAL dIMeNsIONs AC MeAsurINg rANges Table 3 External dimensions of MA16L, MA17L, MA19L, MA12L [mm] meters. OrderINg PrOCedure In the order one must specify: name and type of meter, measuring range, shunt data if the meter is foreseen to co-operate with an interchangeable shunt, working position and eventual additional requirements. Shunt must be ordered separately. Example of order: Ammeter with scale 240 o of MA16L type with a range of 40 A. for use with a shunt type B2 40 A / 60 mV. vertical position 90 °. scale according to the scope without additional requirements. If the shunt is to be delivered with the meter. it should be placed in the order as a sepa- rate item eg. shunt B2 40 A / 60 mV. Frontal frame dimensions [mm] 72 x 72 96 x 96 144 x 144 Scale lenght [mm] 106 142 230 Remarks Weight [kg] 0.25 0.30 0.43 Type MA17L(P) MA19L(P) MA12L(P) Measuring range Drop voltage or power consumption (self-consumption) 100 mA 1.8V 1.8V 1.8V Rated operational range for frequency 1A 75mV 75mV 75mV 5A 75mV 75mV 75mV 10A 75mV 75mV 75mV

40 V 1)

900 W/V 900 W/V 900 W/V

60 V 2)

1) - accuracy class 5 2) - accuracy class 2.5 a a b c c ef g h i i back cover d d Type a b c d e f g h i x y <6A 6-60A >6A IP65 set MA12L 144 5.5 136 137.5 8.5 53 68 64 70 30 37 138+1 none

www.lumel.com.pl Fig. 3. Fixing of meters mA16L, mA17L, mA19L in the panel (version with IP65) * Fig. 2. Fixing of meters mA16L, mA17L, mA19L in the panel (version with IP52) * * Included are two screw holders which should be fixed on arbitrary, opposite case corners

www.lumel.com.pl MAxL-19_en Fig. 4. Fixing of mA12 meters (version with IP52) Code Working position 0 c3  = 90° A c1  = 0° B c2.  = 15° C c2.  = 30° D c2.  = 45° E c2.  = 60° F c2.  = 75° H c4.  = 105° I c4.  = 120° COdINg Of The wOrkINg POsITION Table 4 Code Working position A c3  = 90° B c1  = 0° C c2.  = 15° D c2.  = 30° E c2.  = 45° F c2.  = 60° G c2.  = 75° H c4.  = 105° I c4.  = 120° Table 5 (only for MA16L) Export department: tel.: +48 68 45 75 143, +48 6845 75 141, +48 68 45 75 144, +48 68 45 75 140 fax.: (+48 68) 32 54 091 e-mail: export@lumel.com.pl LUMEL S.A. ul. Słubicka 4, 65-127 Zielona Góra, POLAND tel.: +48 68 45 75 100, fax +48 68 45 75 508 www.lumel.com.pl