M840 ICST | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Integrated Circuit Systems, Inc. Communications Modules www.icst.com/Comm-Modules tel: 508-852-5400 M840 Series Performance Specifications The M840 Series OC-192 Multi-rate Clock Recovery Module provides low jitter clock recovery from NRZ or RZ input data formats. Four data rates, 9.953, 10.3125, 10.664 or 10.709Gb/s may be selected digitally. The input data is amplified by limiting amplifiers. The amplified data is applied to the clock recovery circuitry and provided as an output at a constant level. The module incorporates a frequency multiplied high Q SAW VCO in the clock recovery phase-lock loop to minimize the jitter on the recovered clock. The low noise, excellent stability, and low micro- phonic sensitivity of the SAW based VCO to allow operation with a very narrow phase-lock loop bandwidth necessary to minimize pattern dependent clock jitter. The use of micro-strip band pass filters to filter the recovered clock results in a sinusoidal clock output, having low harmonic and sub-harmonic distortion. The clock recovery circuitry is housed in an easy to interface connectorized module. The discrete circuit design allows for the design to be optimized for various applications and data rates.

4 Selectable NRZ or RZ Data Rates:

9.953, 10.3125, 10.664 & 10.709Gb/s Superior SAW VCO-based PLL Jitter Performance <2psec RMS Jitter 6mV Peak to Peak Input Sensitivity Up to 700mV Peak to Peak Un-retimed NRZ or RZ Data Output Designed and optimized for minimum jitter in accordance with ITU and Bellcore standards for SONET/SDH jitter transfer SONET OC-192/10GbE Test Equipment SONET OC-192/SDH STM Physical Layer Clock and Data Recovery M840 Series OC-192 MULTI-RATE CLOCK RECOVERY MODULE

DESCRIPTION

APPLICATIONS

FEATURES

Performance Specifications Integrated Circuit Systems, Inc. Communications Modules www.icst.com/Comm-Modules tel: 508-852-5400 SPECIFICATIONS Specifications @ Vcc = +5 Volts, Vee = -5 Volts, TA = +25°C unless otherwise specified PARAMETER Min Max Units Conditions Operating Data Rates 9.953 Gb/s

10.3125 Gb/s

10.664 Gb/s

10.709 Gb/s

Selectable Operating Data Rates 1 4 Selected by two TTL inputs (00,01,10,11) Locking Range -0.3 +0.3 % Referenced to nominal bit rate. Data Input Voltage 6 1000 mVp-p NRZ or RZ Input Data BER 10 -12 Data Input Return Loss 9 dB 150kHz to 12.5GHz, 10dB typ. OC-192 Clock Output Frequency 9.953 10.709 GHz OC-48 Clock Output Frequency 2.488 2.677 GHz Clock Output RMS Jitter 0.02 Ul Wideband measured on oscilloscope. PRBS = 223-1 Clock Output Peak-to-Peak Jitter 0.12 Ul Wideband measured on oscilloscope. PRBS = 223-1 Clock Output Voltage 800 1400 mVp-p Clock Output Return Loss 10 dB At output clock frequency ±0.1% Clock Output Harmonic Level -30 dBc Clock Output Sub-harmonic Level -40 dBc Maximum Number of Bits of Consecutive Ones or Zeros 200 Ul Data Output Voltage 200 400 mVp-p Unretimed NRZ or RZ data* Data Output Return Loss 7 dB 150kHz to 12GHz, 10dB Typ Jitter Transfer Bandwidth 4 MHz Set to meet Bellcore jitter transfer requirements while minimizing clock jitter. Loss of Lock Alarm (unlocked) 2.0 5.0 V Loss of Lock Alarm (locked) 0.0 0.8 V +5V Power Supply Voltage 4.75 5.25 V +5V Power Supply Current 0.70 A -5V Power Supply Voltage -4.75 -5.25 V -5V Power Supply Current 0.70 A Control Voltage (Low) 0 0.8 V Standard TTL Levels Control Voltage (High) 2.4 5.0 V Standard TTL Levels Operating Temperature Range 0 +70 °C (case) Package Size 3.2 x 1.57 x .625 In SMA connectors used for Data In, Data Out, OC-192 Clock Out and OC-48 Clock Out *Higher output level available, contact factory.

Integrated Circuit Systems, Inc. Communications Modules www.icst.com/Comm-Modules tel: 508-852-5400 M840 Series Performance Specifications SAW DL 4 OC 192 Clk Out Data Out Data In SAW DL 1 SAW DL 2 SAW DL 3 SP4T SW SP4T SW Pwr Div Pwr Div Op- AmpRF Amp RF Amp RF Amp Lim Amp Lim Amp RF Amp Freq Doubler Freq Doubler Phase ShifterRate Select Freq Pwr Div RF Amp OC 48 Clk Out BLOCK DIAGRAM Single Limiting Amplifier High Level Input Test Data Single Limiting Amplifier Low Level Input Test Data Conditions: Rate = 12.02Gb/sec, Input Level = 1Vpp Conditions: Rate = 12.02Gb/sec, Input Level = 6mVpp Note: M840 has two limiting amplifiers TEST DATA

Performance Specifications Integrated Circuit Systems, Inc. Communications Modules www.icst.com/Comm-Modules tel: 508-852-5400 Integrated Circuit Systems, Inc. Communications Modules

324 Clark Street Worcester, MA 01 606 tel: 508-852-5400 fax: 508-852-8456

European Sales Headquarters Hertogsingel 20 621 4 AD Maastricht The Netherlands tel: +31-43-32-7091 2 fax: +3 1-43-32-707 1 5 www.icst.com/Comm-Modules DoutCout Din MULTI-RATE CLOCK RECOVERY MODULE M840XXXX S/N XXXX 4X SMA CONN COVER SCR'S (FL HD-TOP & BOTTOM) REF MARKING COVER COVER Vcc Vee GND GND ALM CONT 1 1/4Cout Din "A"A "A"A "B "A .625±.020 [15.88±.51] 5X Ø.030 [Ø.76]2X Ø.036 [Ø.91]4X .375 [9.53] 5X .29 [7.4] 3.200 [81.28] 1.575 [40.01] .400 [10.16]] 1.100 1.897 [48.18] 2.684 [68.17] .100 [2.54] 3.000 [76.20] .100 [2.54] 1.375 [34.93] .248 [6.29]

6 EQ SP @

4X .197 [5.00] .50 [12.7] 3X #2-56UNC-2B THD THRU CODED "A" 1X #2-56UNC-2B X .12 [3.05] MIN FULL THD DEPTH CODED "B" 7X Ø.093 AT ENTRY [Ø2.36] MECHANICAL DIMENSIONS & PIN CONFIGURATION PIN DESIGNATIONS Symbol Name Description Din Data Input AC coupled 50 Ω data input Dout Data Output AC coupled 50 Ω data output Cout OC-192 Clock Output (sinusoidal) AC coupled 50 Ω clock output 1/4 Cout OC-48 Clock Output (sinusoidal) AC coupled 50 Ω clock output (1/4 freq. of Cout) Cont1 Frequency Control Line 1 Switch control LSB TTL input signal Cont2 Frequency Control Line 2 Switch control MSB TTL input signal ALM Loss of Lock Alarm TTL output for PLL lock. “0” is locked; “1” is unlocked GND Ground Connection Pins to connect power and control returns through case Vee Negative DC Power Supply -5VDC Power Supply Input Vcc Positive DC Power Supply +5VDC Power Supply Input CLOCK FREQUENCY CONTROL MATRIX Switch Control Clock Frequency Cont 2 Cont 1

10.709 GHz 0 0

10.664 GHz 0 1

10.3125 GHz 1 0

9.953 GHz 1 1

Part Number M844 D XA XB XC XD No. of Frequencies (1-4) Frequency 1 (9.953 GHz) Frequency 2 (if applicable) (10.3125 GHz) Frequency 3 (if applicable) (10.664 GHz) Frequency 4 (if applicable) (10.709 GHz)

ORDERING INFORMATION

Rev. 19.0 ICS reserves the right to make changes in the device data identified in this publication without further notice. ICS advises its customers to obtain the latest version of all device data to verify that any information being relied upon by the customer is current and accurate. VCSO FREQUENCIES AVAILABLE XA 9.953 GHz XB 10.3125 GHz XC 10.664 GHz XD 10.709 GHz